Print this page Download this page as a pdf
Sprinklers » Residential » Residential Sprinklers

A-10 One Inch Adjustable Flat Plate Concealed Pendent 4.9K Model GL4906

"The Inch" Residential Automatic Sprinklers Model GL4906 One Inch Adjustable Flat Plate Concealed Pendent

Description and Operation

SprinklersThe Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a flat plate profile that utilizes a 3mm frangible glass ampule as the thermosensitive element. It features economy, aesthetics and the lowest allowable water flow with a nominal 1" of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of Underwriters Laboratories Inc. as described in UL Standard, 1626, for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction.

All that is seen at the ceiling is the 3 5/16" diameter flat ceiling plate color finished to match the specifier's exact requirements. The ceiling plate is soldered to the sprinkler's special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the residential pendent spray sprinkler. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distributed in an approved pattern.

Technical data

  • Temperature Rating - 155°F (68°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating - -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 155°F 68°C Red 100°F 38°C

Specifications and Approvals

Sin ModelK FactorThread SizeLengthFinishes155°F
68°C
cULus
GL4906 4.9
(68 metric)
1/2" NPT 3" (7.6 cm)

Bright Chrome
White Painted
Bright Brass1
Satin Chrome1
Other Painted Finishes1

Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order. for painted plates other than white, contact Globe for ordering specifications.

Cross Section

Click image above for a detailed view of this product.

Installation Data for Flat and Sloped Ceilings**

ModelMaximum Area of CoverageMinimum Water Discharge &
Pressures Needed Per Sprinkler*
GL4906 12' x 12' 13 G.P.M. - 7 P.S.I.
14' x 14' 13 G.P.M. - 7 P.S.I.
16' x 16' 13 G.P.M. - 7 P.S.I.
18' x 18' 17 G.P.M. - 12 P.S.I.
20' x 20' 20 G.P.M. - 16.7 P.S.I.

*When these sprinklers are used in NFPA 13 systems, A 0.1 design density minimum shall be utilized.

**Refer to page 2 of the Globe Residential Sprinkler Installation Guide for NFPA 13D and 13R requirements.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 332765
  • Quantity - Protective Caps - P/N 332868
Cover Plate Size White 135°F Part # Chrome 135°F Part #
3 5/16" 332892 332891

Product Related Documents

Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-3 Clean Room Cover Plates

Cover Plate with a Gasket Seal for Clean Room Application

Cover Plate

Cover Plates

The Seal is intended for areas where it is desirable to stop air travel through the cover plate from the area above the ceiling.

For "The Inch" Standard Response GL5653, For Full Description See Pages: A-69-CR

Finish/Part No. 135°:
  • Chrome: 332739
  • White: 332737
Finish/Part No. 155°:
  • Chrome: 332740
  • White: 332741
cULus Approved:GL5653 -135°F (57°C) with plate 135°F (57°C);
155°F (68°C) with plate 135°F (57°C); 155°F (68°C) with plate (68°C);
175°F (79°C) with plate 155°F (68°C); 200°F (93°C) with plate 155°F
(68°C)

 

 



Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-3 Concealed Cover Plates

Concealed Cover Plates to Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D, & E

Concealed Cover Plates

For "The Inch" Quick Response GL5606 & Standard Response GL5653

Finish/Part No. 135°
  • Chrome: 332821
  • White: 332822
Finish/Part No.155°
  • Chrome: 332827
  • White: 332828
  • cULus Approved: GL5653 -135°F (57°C) with plate 135°F
    (57°C);155°F (68°C) with plate 135°F (57°C); 155°F (68°C)
    with plate (68°C); 175°F (79°C) with plate 155°F (68°C); 200°F
    (93°C) with plate 155°F (68°C)

For full descriptions see pages: A-38-EQ, & A-69-EQ

 



Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-3 Recessed Escutcheons

Recessed Escutcheons to Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D, & E

Recessed Escutcheons

Recessed Escutheons

2 Pc. Recessed
1/2" Adjustable

Finish/Part No. 1/2” NPT:
  • Chrome: 326201
  • White: 326203-W
Finish/Part No. 3/4” NPT:
  • Chrome: 326208
  • White: 326210-W

3/4" Adjustable

Finish/Part No. 1/2” NPT:
  • Chrome: 326170
  • White: 326172-W
Finish/Part No. 3/4” NPT:
  • Chrome: 326177
  • White: 326179-W

1/2" Adjustable Recessed Model Numbers

  • cULus Approved: 2810,4110,4210,4230,4231,
    4234,4710,5628,5630,5631,8101,8107,8128,8129,
    8151 & 8174
  • cULUs & FM Approved: 5601,8106, 8156 & 5635

 

3/4" Adjustable Recessed Model Numbers Seismic

  • cULus Approved:2801,2826,2851,2870,4201,4226,
    4231,4251,4270,5601,5602,5626,5628,5635,5636,5641,
    5642,5652,5670,5680,5685,5686,8101,8102,8152,8106,
    8107,8109,8127,8128,8129,8135,8141,8157,8159,8171,
    8174,8179,8185
  • cULus & FM Approved: 5651, 8156, 8151 & 5679

For full descriptions see pages:: A-24-EQ, A-41-EQ, A-55-EQ, A-67-EQ, A-76-EQ & A-90-EQ

 



Download this page as a pdf
Dry Sprinklers » Dry Type Pendent

A-90EQ Automatic Sprinklers GL Series Dry Type Recessed Pendent

Automatic Sprinklers GL Series Dry Type Recessed Pendent To Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Description and Operation

The Globe GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe GL Series Dry Type Pendent Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

The use of the 4 1/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E.

The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT

cULus Variable
to 48"

Bright Chrome
White Polyester

8.1 (116 metric) 1" NPT FM Variable
to 36"
Note:
  • Metric conversions are approximate.
  • cULus listed corrosion resistant: Polyester must be specified on order.
  • 1Finishes available on special order.
  • 2 Wax Coating cULus listed up to 200°F

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULus*FMNYC - DOB
MEA 101-92-E
Recessed
Pendent
GL5679 5.6 1" NPT
GL5680 5.6 ¾" NPT
GL8179 8.1 1" NPT
Note:
  • Listed for all hazards
  • FM Approved 155°F and 200°F only.

Cross Section

Click image above for a detailed view of this product

Installation Data

Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Pendent

A-76EQ Extended Coverage Light Hazard Automatic Sprinklers Model GL8159 Pendent

Extended Coverage Light Hazard Automatic Sprinklers Model GL8159 Pendent To Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Description and Operation

The Globe Model GL8159-EQ Extended Coverage Pendent Sprinkler for Light Hazard occupancies is a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various light hazard area coverages and should be installed in accordance with NFPA 13. This sprinkler series is available in four temperature ratings and several finishes to meet many varying design requirements.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

The use of the 4 1/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E.

The sprinkler, and escutcheon are not factory assembled. Assembly is done at the time of installation.


Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (74°C)
    200°F (93°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 3" (7.6 cm) Factory Bronze
*Satin Chrome
Bright Chrome
White Polyester+
Black Polyester+
*Lead Coated+
Note:
  • Metric conversions are approximate.
  • *Finishes available on special order.
  • +Available as UL listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
cULus
Pendent GL8159 8.1

U.L. Listing Design - Use Requirements For Light Hazards Only

StyleTEMPArea of
Coverage
MIN. PRESSURE
P.S.I.
FLOW
G.P.M.
Recessed Pendent 135°F / 57°C
155°F / 68°C
175°F / 79°C
200°F / 93°C
16' x 16' 10.3 26
18' x 18' 16.6 33
20' x 20' 24.4 40
Note: Due to the high spray pattern created by the spinkler, there must be a minmum spacing of 8'-0" between sprinklers to eliminate the risk of cold soldering.

Cross Sections

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325401, Rev. D
  • Quantity - Protective Caps - P/N 327109-CAP
    (Friction Fit Recessed)

Download this page as a pdf
Dry Sprinklers » Dry Type Pendent

A-55EQ Quick Response Automatic Sprinklers GL Series Dry Type Recessed Pendent

Quick Response Automatic Sprinklers GL Series Dry Type Recessed Pendent To Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Description and Operation

The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

The use of the 4 1/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E.

The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT

cULus Variable
to 48"

Bright Chrome
White Polyester

8.1 (116 metric) 1" NPT FM Variable
to 36"
Note:
  • Metric conversions are approximate.
  • cULus listed corrosion resistant: Polyester must be specified on order.
  • 1Finishes available on special order.
  • 2Lead coated is cULus approved only.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
*FMcULus
Recessed
Pendent
GL5635 5.6 1" NPT
GL5636 5.6 ¾" NPT
GL8135 8.1 1" NPT
Note:
  • Listed for all hazards
  • FM Approved 155°F and 200°F only.

Cross Section

Click image above for a detailed view of this product

Installation Data

Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

For further important installation data, please refer to our Dry Sprinkler Caution Sheet.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Pendent

A-41EQ Extended Coverage Light Hazard Automatic Sprinklers Model GL8109

Extended Coverage Light Hazard Automatic Sprinklers Model GL8109 Pendent To Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Description and Operation

Sprinklers

The Globe Quick Response Model GL8109-EQ Extended Coverage Pendent Sprinkler for Light Hazard occupancies is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermo sensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While this Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard light hazard extended coverage pendent sprinklers are specified; but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accordance with NFPA 13.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

The use of the 4 1/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E.

The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation.

Technical Data

  • Temperature Ratings
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 3" (7.6 cm) Bright Chrome
White Polyester+
NOTE:
  • Metric conversions are approximate.
  • +Available as cULus listed corrosion resistant when specified on order.

Approvals

StyleSin ModelK
Factor
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
cULus
Pendent
GL8109 8.1

Sin ModelStyleTemp.Area of CoverageMin. Pressure
P.S.I.
Flow in G.P.M.
GL8109
Recessed 135°F/57°C
155°F/68°C
175°F/79°C
200°F/93°C
16' x 16'
10.3 26
18' x 18' 16.6 33
135°F/57°C 20' x 20' 24.4 40
NOTE:
  • Due to high spray pattern created by this sprinkler, there must be a minimum spacing of 8'-0" between sprinklers to eliminate the risk of cold soldering.

Cross Sections

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325401, Rev. D
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Standard Response - Standard Spray Sprinkler

A-67EQ Automatic Sprinklers GL Series Dry Type Recessed Pendent

Automatic Sprinklers GL Series Recessed Pendent To Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Sprinklers

The GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified. This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements.

The heart of Globe’s GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass, causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

The use of the 4 1/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E.

The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation.

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C),
    200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Nominal 'K' FactorThread Size Length Finishes
2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
Satin Chrome2
Bright Chrome
White Polyester3
Black Polyester3
Lead Coated2
4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm)
5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm)
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm)
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • 2 Finishes available on special order.
  • 3 Available as cULus listed corrosion resistant when specified on order.

StyleSin
Model
K
Factor
135° F
57° C
155° F
68° C
175° F
79° C
200° F
93° C
**286°F
141° C
†cULusFMLPCCENYC - DOB
MEA
101-92-E
Pendent
Recessed
GL2851 2.8
GL4251 4.2
GL5651 5.6
GL8151* 7.8*
GL8156 8.1 $
Note:
  • † 5.6K Orifice, 7.8K Orifice and 8.1K Orifice listed for all hazards.
  • *7.8" X 1/2" NPT
  • ** 286°F cULus listed only.
    $ Brass finish only

Click image above for a detailed view of this product.

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325391, Rev. F (1/2"); P/N 325401, Rev. D (L.O.)
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)


Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Quick Response - Standard Spray Sprinkler

A-24EQ Automatic Sprinklers GL Series Recessed Pendent

Automatic Sprinklers GL Series Recessed Pendent To Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Description and Operation

Sprinklers

The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe’s GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

The use of the 4 1/2" diameter recessed escutcheon allows for 1" of clearance around the sprinkler body, and meets the IBC-ASCE/SEI 7 requirements for use in seismic design categories C, D & E.

The sprinkler and escutcheon are not factory assembled. Assembly is done at the time of installation.

Technical Data

  • Temperature Ratings
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm)

Chrome

White Polyester1

4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm)
5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm)
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm)
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
NOTE:
  • Metric conversions are approximate.
  • 1cULus listed corrosion ressistant - Polyester must be specified on order.

Approvals

StyleSin ModelK
Factor
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
**286°F
141°C
cULusFM††LPCCENYC-DOB
MEA 101-92-E
Pendent
Recessed
GL2801 2.8
GL4201 4.2
GL5601 5.6†
GL8101 7.8†
GL8106 8.1†
NOTE:
  • † 5.6K orifice, 7.8K orifice and 8.1K orifice listed for all hazards.
    **286°F cULus listed only.
    Upright vertical sidewall cULus listed for 9' min. spacing.
    ††1/2" Recessed escutcheons are required for FM approved sprinklers.

Cross Sections

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325391 (1/2"); P/N 325401, Rev. F (L.O.)
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Download this page as a pdf
Sprinklers » Residential » Residential Sprinklers

A-3 Automatic Sprinklers Model GL3010

Automatic Spinklers Model GL3010 Pendent Recessed Pendent

Description and OperationSprinklers

The Globe Model GL3010 Residential Sprinkler has a low profile yet durable design, which utilizes a 3mm frangible glass ampule as the thermosensitive element. It features economy, aesthetics and low flow.

The combination of the 3mm frangible glass ampule and specially designed deflector makes the Model GL3010 Residential Sprinkler the ultimate in life safety and fire control. This Globe Pendent and Recessed Pendent Residential Sprinkler has met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction.

The heart of Globe's Model GL3010 sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Rating - 155°F (68°C)
  • Water Working Pressure Rating - 175 psi (12 Bars).
  • Factory tested hydrostatically to 500 psi (34 Bars).
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C).
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size.
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

Classification Available Sprinkler Temperatures Bulb Color N.F.P.A. Maximum Ceiling Temperature
Ordinary 155°F 68°C Red 100°F 38°C

Specifications and Approvals

Sin Model K Factor Thread Size Length Finishes 155°F
68°C
NYC-DOB
MEA 101-92-E
GL3010 3.0
(42 metric)
1/2" NPT 2 1/2" (6.4 cm) Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2C-U.L. Listed Corrosion Resistant - Polyester must be specified on order.

Cross Section

Gl5635

Click image above for a detailed view of this product.

Installation Data for Flat and Sloped Ceilings**

Pendent and Recessed Pendent

Maximum Area of Coverage Minimum Water Discharge &
Pressures Needed Per Sprinkler*
12' x 12' 8 G.P.M. - 7.1 P.S.I.
14' x 14' 10 G.P.M. - 11.1 P.S.I.

*When these sprinklers are used in NFPA 13 systems, a 0.1 design density minimum shall be utilized.

**Refer to page 2 of the Globe Residential Sprinkler Installation Guide for NFPA 13D and 13R requirements.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390
  • Quantity - Recessed Wrenches - P/N 325391
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 ¾” NPT Recessed Wrench 325401

¾" NPT RECESSED WRENCH
P/N 325401

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 Residential Sidewall Recessed Wrench (327102)

RESIDENTIAL SIDEWALL RECESSED WRENCH
P/N 327102

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories » Dry Sprinklers » Dry Type Accessories

B-4 Dry Sprinkler Recessed Wrench (337014)

DRY SPRINKLER RECESSED WRENCH
P/N 337014

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 ¾” NPT EXTRA LARGE ORIFICE WRENCH (333010)

¾" NPT EXTRA LARGE ORIFICE WRENCH
P/N 333010

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 1/2” NPT 1” Adjustable Concealed Wrench (332765)

1/2" NPT 1" ADJUSTABLE CONCEALED WRENCH
P/N 332765Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 ½” NPT MILLENNIUM WRENCH (332334)

½" NPT MILLENNIUM WRENCH
P/N 332334

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 ½” NPT Recessed / Concealed Wrench (325391)

½" NPT RECESSED / CONCEALED WRENCH

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 ¾” NPT Standard Wrench (312366)

¾" NPT STANDARD WRENCH

Wrench Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-4 ½” NPT Standard Wrench (325390)

½" NPT STANDARD WRENCH

Wrench Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Quick Response - Standard Spray Sprinkler

A-26 Automatic Sprinklers GL Series 10MM   Upright • Pendent • Recessed Pendent

Quick Response Automatic Sprinklers GL Series 10MM
Upright • Pendent • Recessed PendentQuick Response

Description and Operation

The Globe Quick Response GL Series 10mm Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response 10mm Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe's GL Series sprinkler-proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands, increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass, causing the glass to shatter. This results in water discharge which is distributed in an approved pattern, depending upon the deflector style used.

The sprinkler and escutcheon are not factory assembled. Assembly is done in the field.

 

Technical Data

  • Temperature Ratings - 57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F), 141°C (286°F)
  • Water Working Pressure Rating - 12 Bars
  • Factory tested hydrostatically to 34 Bars
  • Maximum low temperature glass bulb rating is
    -55°C (-65°F ).
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 57°C/68°C 135°F/155°F Orange/Red 38°C 100°F
Intermediate 79°C/93°C 175°F/200°F Yellow/Green 66°C 150°F
High 141°C 286°F Blue 107°C 225°F

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
57 METRIC 10mm
(ISO 7/1-R3/8)
5.7 cm Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as c-UL listed corrosion resistant when specified on order.

Approvals

StyleSin ModelK Factor57°C
(135°F)
68°C
(155°F)
79°C
(175°F)
93°C
(200°F)
141°C
(286°F)
cULus
Upright GL4221 57 Metric
Pendent
Recessed
Pendent
GL4202 57 Metric

Cross Sections

larger image

Ordering Information

When ordering, please specify the following:

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Standard Response - Standard Spray Sprinkler

A-64 Automatic Sprinklers GL Series 10MM Upright • Pendent • Recessed Pendent

Automatic Sprinklers GL Series 10MM
Upright • Pendent • Recessed PendentAutomatic GL SEries 10MM

Description and Operation

The Globe GL Series10mm Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the10mm sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified. This sprinkler series is available in various styles, temperature ratings and finishes to meet varying design requirements.

The heart of Globe's GL Series sprinkler-proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands, increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass, causing the glass to shatter. This results in water discharge which is distributed in an approved pattern, depending upon the deflector style used.

The sprinkler and escutcheon are not factory assembled. Assembly is done in the field.

 

 

 

Technical Data

  • Temperature Ratings - 57°C (135°F), 68°C (155°F), 79°C (175°F), 93°C (200°F), 141°C (286°F), 182°C (360°F)
  • Water Working Pressure Rating - 12 Bars
  • Factory tested hydrostatically to 34 Bars
  • Maximum low temperature glass bulb rating is
    -55°C (-65°F ).
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 57°C/68°C 135°F/155°F Orange/Red 38°C 100°F
Intermediate 79°C/93°C 175°F/200°F Yellow/Green 66°C 150°F
High 141°C 286°F Blue 107°C 225°F
Extra High 182°C 360°F Mauve 149°C 300°F

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
57 METRIC 10mm
(ISO 7/1-R3/8)
5.7 cm Factory Bronze
Satin Chrome1
Bright Chrome3
White Polyester3
Black Polyester3
Wax Coated2,3
Lead Coated1,3
Wax Over Lead2,3
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2 Wax Coating UL listed up to 200°F only.
  • 3cUL listed corrosion resistant polyester must be specified on order.

Approvals

Note:
StyleSin ModelK Factor57°C
135°F
68°C
155°F
79°C
175°F
93°C
200°F
141°C
286°F
182°C
360°F
cULus
Upright GL4262 57 Metric  
Pendent
Recessed
Pendent
GL4252 57 Metric  

Cross Sections

larger image

Ordering Information

When ordering, please specify the following:

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390

Sprinklers, Nozzles & Accessories

 Standard Spray Sprinklers    Residential Sprinklers    Extended Coverage Sprinklers

 

 Sprinkler Accessories        Caution Sheets

 

 

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » "The Inch" for Seismic Applications

A-69EQ “The Inch” Adjustable Concealed Pendent Sprinkler Seismic Application - GL5653

Automatic Sprinklers

"The Inch"
Model GL5653 One Inch
Adjustable Concealed Pendent
with Cover Plate to meet IBC-ASCE/SEI 7 Codes for Seismic Areas C,D, & E.

Description and Operation

concealed pendent

The Globe GL5653 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. The 4 1/2" diameter cover plate allows for 1" clearance around the sprinkler body and meets the IBC-ASCE/SEI 7 requirements for the use in seismic design categories C, D, & E. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 5mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate.

The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off" designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling.

Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 5mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin based solution, 5mm size
  • Drop Pin - stainless steel
  • Cover Plate - brass
  • Upper Escutcheon Assembly - plated steel
  • Note: Globe's wrench P/N 332765 must be used to install this sprinkler.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) Bright Chrome
White Painted
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.

Approvals

StyleSin ModelK Factor135°F
(57°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
155°F
(68°C)
175°F
(79°C)
with plate
155°F
(68°C)
200°F
(93°C)
with plate
155°F
(68°C)
cULus
Adjustable
Concealed
Pendent
GL5653 5.6

Cross Section

cross section

CEILING

PLATES

White 135°F
Part #
White 155°F
Part #
Chrome 135°F
Part #
Chrome 155°F
Part #
332822 332828 332821 332827

 

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Adjustable Concealed Wrenches - P/N 332765

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » "The Inch" for Clean Rooms

A-69CR “The Inch for Clean Rooms” One Inch Adjustable Concealed Pendent Model GL5653

Automatic Sprinklers

"The Inch for Clean Rooms"
Automatic Sprinklers
One Inch Adjustable
Concealed Pendent Model GL5653

Description and Operation

concealed pendent

The Globe GL5653 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 3/8" diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling.

The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off" designed cover plate is easily installed with a nominal 1" inch of adjustment.

Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern.

Features

  • Cover Plate with a gasket seal assembly for dust free environment, such as "Clean Rooms".
  • Nominal 1" of Adjustment.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin based solution, 5mm size
  • Drop Pin - stainless steel
  • Cover Plate - brass
  • Upper Escutcheon Assembly - plated steel
  • Gasket Seal - Santoprene
  • Note: Globe's wrench P/N 332765 must be used to install this sprinkler.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) Bright Chrome
White Painted
Other Painted Finishes1
(Gasket color White only)
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.

Approvals

StyleSin ModelK Factor135°F
(57°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
155°F
(68°C)
175°F
(79°C)
with plate
155°F
(68°C)
200°F
(93°C)
with plate
155°F
(68°C)
cULus
Adjustable
Concealed
Pendent
GL5653 5.6

Cross Section

cross section
White 135°F
Part #
White 155°F
Part #
Chrome 135°F
Part #
Chrome 155°F
Part #
Min. Ceiling
Hole Dia.
332737 332741 332739 332740 2 1/4"

 

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Adjustable Concealed Wrenches - P/N 332765

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » "The Inch" for Seismic Applications

A-38EQ “The Inch” Automatic Sprinkler Seismic Application -  Model GL5606

Quick Response

"The Inch" Automatic Sprinklers Model GL5606, One Inch Adjustable Concealed Pendent
w/Cover Plate to Meet IBC-ASCE/SEI 7 Codes for Seismic Areas C, D & E

Description and Operation

Quick Response

The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. The 4 1/2" diameter cover plate allows for 1" clearance around the sprinkler body and meets the IBC-ASCE/SEI 7 requirements for the use in seismic design categories C, D, & E. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate.

The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off" designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling.

Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Drop Pin - stainless steel
  • Cover Plate - brass
  • Upper Escutcheon Assembly - plated steel

  • NOTE: Globe's wrench P/N 332765 must be used to install this sprinkler.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes*
5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) Bright Chrome
White Painted

Note:
  • Metric conversions are approximate.
  • *Finishes available on special order.

Approvals

StyleSin ModelK Factor135°F
(57°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
155°F
(68°C)
175°F
(79°C)
with plate
155°F
(68°C)
200°F
(93°C)
with plate
155°F
(68°C)
cULus
Adjustable
Concealed
Pendent
GL5606 5.6

Cross Section

larger image

White 135°F
Part #
White 155°F
Part #
Chrome 135°F
Part #
Chrome 155°F
Part #
Ceiling Plates 332822 332828 332821 332827

 

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Adjustable Concealed Wrenches - P/N 332765

Product Related Documents

Download this page as a pdf
Sprinklers » Caution Sheets

The Inch Caution Sheet

"The Inch" Automatic Sprinklers Model GL5653 & GL5606 One Inch Adjustable Concealed Pendent

Installation Instructions - Read Carefully

The Inch

Position

Commercial or Residential Pendent Spray Sprinkler. Install in pendent position only.

Warning

Sprinklers contained in this carton have been manufactured and tested in accordance with the applicable standards or where applicable under the inspection of Underwriters Laboratories Inc., and FM Approvals.

Any alteration to the sprinkler after it leaves the factory including, but not limited to painting, plating, coating or other alteration, may render the sprinkler inoperative and will nullify the Listing of Underwriters Laboratories Inc., and FM Approvals.

Glass bulbs are very fragile. Handle with extreme care. Sprinklers should be kept in the carton provided with dividers at all times prior to installation. Sprinklers should never come in direct contact with one another or any other foreign object prior to installation. Do not place sprinklers in a bucket. Globe Fire Sprinkler Corporation is not responsible for glass bulb damage due to improper handling.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler
Temperatures
Bulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Important Precautions to Follow

  • Globe Sprinklers are to be installed in accordance with the latest published standards of the National Fire Protection Association, Globe Sprinkler data sheets, Government agencies and/or other similar organizations and to meet local codes and ordinances.
  • The protective cover provided is to be installed after sprinkler installation for integrity as long as work is being done by any contractor in the area. This prevents accidental sprinkler damage. Protective caps are to be removed when cover plates are installed.
  • Care should be taken not to bend deflector drop pins at installation. Deflector is to fall freely after installation.
  • Never install a sprinkler after it has dropped to the floor or been injured in any way. These sprinklers should be discarded.
  • Never install sprinklers in the fittings until the piping is in place on the ceiling as sprinklers are liable to be injured if screwed into the fittings when the lines are made up at the bench.
  • Never paint or whitewash sprinklers as this is liable to prevent their operation in a fire.
  • Never install sprinklers in pendent position on a dry system unless of a type designed for this purpose and as permitted by NFPA 13 and the authority having jurisdiction.
  • Never attach wiring, ropes or fixtures to sprinkler or sprinkler piping.
  • Globe's wrench P/N 332765 must be used to install this sprinkler.
  • Sprinklers must remain separated from each other at all times. Allowing metal parts to come in contact with the glass bulb can cause damage, causing premature operation.
  • Store sprinklers in cool, dry place and preferably in their shipping carton.
  • Sprinklers of proper rating must be carefully selected to meet the temperature conditions where they are located (see table on reverse side for available temperatures). 175°F (79°C) or lower sprinklers should not be installed in locations less than 30" above or 12" to one side of steam pipes, heating coils or radiators. 200°F (93°C) sprinkler should be used under skylights where exposed to direct sun rays. Consult the local authority having jurisdiction to determine the proper temperature ratings in special locations such as:
    • Areas near unit heaters.
    • Areas where low pressure blow-off discharges into a large room.
    • Areas in an unventilated concealed space under uninsulated wood or tin roofs.
    • Areas in an unventilated attic.
    • Areas in a shed with an unventilated peak roof or thin boards or metal.
    • Areas where show windows have high powered electric illumination processes.
    • Areas where a locomotive enters a building.
    • Areas in other locations where special consideration is necessary.
  • Inspect sprinklers regularly for mechanical damage, corrosion, paint and dust buildup as outlined in NFPA publications.
  • All automatic sprinklers should be replaced in accordance with the latest NFPA 25 requirements, or as conditions warrant.
  • When replacing sprinklers in any system, make sure those replacements are of the same style, size, and temperature rating as those removed.
  • Should a change in building structure, occupancy or temperature conditions indicate a probable change in sprinkler requirements, notify the insurance carrier or other qualified inspection agency immediately. Do not make any changes without the authorization of one of these agencies.
  • Maintain an extra stock of sprinklers and wrenches in a cabinet as required by NFPA 13.
  • Concealed sprinklers and recessed sprinklers should not be used if the space above the ceiling is used for delivery (positive pressure) in an HVAC system.
  • Globe Fire Sprinkler Corporation sprinklers have been tested, listed or approved by the agencies noted on the individual sprinkler data sheet. Acceptance by other agencies or authorities is not the responsibility of Globe Fire Sprinkler Corporation. Globe Fire Sprinkler Corporation is not liable for any costs arising as a result of any changes to listings or approvals after shipment. The Seller makes no warranties express or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose except as expressly stated in seller's sales contract or sales acknowledgment form.

Download this page as a pdf
Sprinklers » Caution Sheets

Millennium Caution Sheet

Automatic Sprinklers Millennium GL Series Caution

Installation Instructions - Read Carefully

Millennium

Position

Commercial or Residential Pendent Spray Sprinkler. Install in pendent position only.

Warning

Sprinklers contained in this carton have been manufactured and tested in accordance with the applicable standards and under the inspection of Underwriters Laboratories Inc.

Any alteration to the sprinkler after it leaves the factory, including, but not limited to, painting, plating, coating or other alteration, may render the sprinkler inoperative and will nullify the Listing of Underwriters Laboratories Inc. Glass bulbs are very fragile. Handle with extreme care. Sprinklers should be kept in the carton provided with dividers at all times prior to installation. Sprinklers should never come in direct contact with one another or any other foreign object prior to installation. Do not place sprinklers in a bucket. Globe Fire Sprinkler Corporation is not responsible for glass bulb damage due to improper handling.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler
Temperatures
Bulb Color

N.F.P.A. Maximum
Ceiling Temperature

Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Important Precautions to Follow

  • Globe Sprinklers are to be installed in accordance with the latest published standards of the National Fire Protection Association, Globe Sprinkler data sheets, Government agencies and/or other similar organizations and to meet local codes and ordinances.
  • Never install an Upright Spray Sprinkler in a pendent position or a Pendent Spray Sprinkler in an upright position.
  • Use only a special sprinkler wrench to install sprinklers. Any other wrench is liable to injure the sprinkler.
  • The protective cover should be left on as long as work is being done by any contractor in the area to prevent accidental damage.
  • Never install a sprinkler after it has dropped to the floor or been injured in any way. These sprinklers should be discarded.
  • Never install sprinklers in the fittings until the piping is in place on the ceiling as sprinklers are liable to be injured if screwed into the fittings when the lines are made up at the bench.
  • Never paint or whitewash sprinklers as this is liable to prevent their operation in a fire.
  • Never install sprinklers in pendent position on a dry system unless of a type designed for this purpose and as permitted by NFPA 13 and the authority having jurisdiction.
  • Never attach wiring, ropes or fixtures to sprinkler or sprinkler piping.
  • Sprinklers must remain separated from each other at all times. Allowing metal parts to come in contact with the glass bulb can cause damage, causing premature operation.
  • Wax Coated, Lead Plated or Wax over Lead sprinklers should be used in all locations subject to corrosion from acid fumes, chemicals, processes, etc. Extreme care must be exercised when installing to avoid damage to coating.
  • Use sprinkler guards on all sprinklers subject to injury by moving objects.
  • Store sprinklers in cool, dry place and preferably in their shipping carton.
  • Sprinklers of proper rating must be carefully selected to meet the temperature conditions where they are located (see table below for available temperatures). 175°F (79°C) or lower sprinklers should not be installed in locations less than 30" above or 12" to one side of steam pipes, heating coils or radiators. 200°F (93°C) sprinkler should be used under skylights where exposed to direct sun rays. Consult the local authority having jurisdiction to determine the proper temperature ratings in special locations such as:
    • Areas near unit heaters.
    • Areas where low pressure blow-off discharges into a large room.
    • Areas in an unventilated concealed space under uninsulated wood or tin roofs.
    • Areas in an unventilated attic.
    • Areas in a shed with an unventilated peak roof or thin boards or metal.
    • Areas where show windows have high powered electric illumination processes.
    • Areas where a locomotive enters a building.
    • Areas in other locations where special consideration is necessary.
  • Inspect sprinklers regularly for mechanical damage, corrosion, paint and dust buildup as outlined in NFPA publications.
  • All automatic sprinklers should be replaced in accordance with the latest NFPA 25 requirements, or as conditions warrant.
  • When replacing sprinklers in any system, make sure those replacements are of the same style, size, and temperature rating as those removed.
  • Should a change in building structure, occupancy or temperature conditions indicate a probable change in sprinkler requirements, notify the insurance carrier or other qualified inspection agency immediately. Do not make any changes without the authorization of one of these agencies.
  • Maintain an extra stock of sprinklers and wrenches in a cabinet as required by NFPA 13.
  • Concealed sprinklers and recessed sprinklers should not be used if the space above the ceiling is used for delivery (positive pressure) in an HVAC system.
  • Globe Fire Sprinkler Corporation sprinklers have been tested, listed or approved by the agencies noted on the individual sprinkler data sheet. Acceptance by other agencies or authorities is not the responsibility of Globe Fire Sprinkler Corporation. Globe Fire Sprinkler Corporation is not liable for any costs arising as a result of any changes to listings or approvals after shipment. The Seller makes no warranties express or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose except as expressly stated in seller's sales contract or sales acknowledgment form.

Download this page as a pdf
Sprinklers » Caution Sheets » Dry Sprinklers » Dry Type Caution Sheets

GL Series Dry Type Caution Sheet

Automatic Sprinklers GL Series Dry Type Cautions

Installation Instructions - Read Carefully

Gl Series

Standard and Large Orifice Upright Sprinkler. Install in upright position only. Identified by "SSU" on deflector. Standard and Large Orifice Pendent Sprinkler. Install in pendent position only. Identified by "SSP" on deflector. Standard and Large Orifice Horizontal Sidewall Sprinkler. Install in horizontal position only. Identified by "TOP" on deflector. Standard and Large Orifice Vertical Sidewall Sprinkler. Install in the upright or pendent positions. Identified by "FLOW" on deflector.

Warning

Sprinklers contained in this carton have been manufactured and tested in accordance with the applicable standards or where applicable under the inspection of Underwriters Laboratories Inc., and FM Approvals. See individual data sheets for specific approvals.

Any alteration to the sprinkler after it leaves the factory including, but not limited to painting, plating, coating or other alteration, may render the sprinkler inoperative and will nullify the listings and approvals.

Glass bulbs are very fragile. Handle with extreme care. Sprinklers should be kept in the carton provided with dividers at all times prior to installation. Sprinklers should never come in direct contact with one another or any other foreign object prior to installation. Do not place sprinklers in a bucket. Globe Fire Sprinkler Corporation is not responsible for glass bulb damage due to improper handling.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler
Temperatures
Bulb Color

N.F.P.A. Maximum
Ceiling Temperature

ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C
INTERMEDIATE 175°F/200°F 79°C/93°C GREEN/YELLOW 150°F 66°C
HIGH 286°F 141°C BLUE 225°F 107°C

Important Precautions to Follow

  • Globe Sprinklers are to be installed in accordance with the latest published standards of the National Fire Protection Association, Loss Prevention Council, Globe Sprinkler data sheets, Government agencies and/or other similar organizations and to meet local codes and ordinances.
  • Never replace a Large Orifice Sprinkler with a standard sprinkler or vice versa.
  • Never install an Upright Spray Sprinkler in a pendent position or a Pendent Spray Sprinkler in an upright position.
  • Install using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.
  • Minimum operating pressure for dry upright is 12 psi.
  • Install Globe GL Series Dry Type Sprinklers in 1"NPT or ¾"NPT tees only - ANSI B16.3 Class 155 or ANSI B16.4 Class 125. Tyco Blazemaster® CPVC Fittings have been evaluated and found acceptable for use. Other plastic fittings may be acceptable but we have not received samples for evaluation.
  • Never install a sprinkler after it has dropped to the floor or been injured in any way. These sprinklers should be returned to the factory for examination.
  • Never install sprinklers in the fittings until the piping is in place on the ceiling as sprinklers are liable to be injured if screwed into the fittings when the lines are made up at the bench.
  • Never paint or whitewash sprinklers as this is liable to prevent their operation in a fire.
  • Never attach wiring, ropes or fixtures to sprinkler or sprinkler piping.
  • Lead Plated sprinklers should be used in all locations subject to corrosion from acid fumes, chemicals, processes, etc. Extreme care must be exercised when installing to avoid damage to coating.
  • Use sprinkler guards on all sprinklers subject to injury by moving objects.
  • Some Globe Fire Sprinkler Corporation sprinkler models are shipped with a factory applied sealant on the threads. Globe recommends that no additional tape or pipe dope be used on these sprinklers. If pipe compound is used on sprinklers without factory applied sealant, apply to sprinkler threads only. Wipe all excess compound off sprinkler.
  • Store sprinklers in cool, dry place and preferably in their shipping carton.
  • Sprinklers of proper rating must be carefully selected to meet the temperature conditions where they are located (see table on reverse side for available temperatures). 175°F (79°C) or lower sprinklers should not be installed in locations less than 30" above or 12" to one side of steam pipes, heating coils or radiators. 200°F (93°C) sprinkler should be used under skylights where exposed to direct sun rays. Consult the local authority having jurisdiction to determine the proper temperature ratings in special locations such as:
    • Areas near unit heaters.
    • Areas where low pressure blow-off discharges into a large room.
    • Areas in an unventilated concealed
      space under uninsulated wood or tin roofs.
    • Areas in an unventilated attic.
    • Areas in a shed with an unventilated peak roof or thin boards or metal.
    • Areas where show windows have high powered electric illumination processes.
    • Areas where a locomotive enters a building.
    • Areas in other locations where special consideration is necessary.
  • Inspect sprinklers regularly for mechanical damage, corrosion, paint and dust buildup as outlined in NFPA publications.
  • Dry type sprinklers should be replaced after 10 years of service or as conditions warrant.
  • High temperature sprinklers (360°F and higher) should be replaced after 5 years of service or as conditions warrant.
  • When replacing sprinklers in any system, make sure those replacements are of the same style, size, and temperature rating as those removed.
  • Should a change in building structure, occupancy or temperature conditions indicate a probable change in sprinkler requirements, notify the insurance carrier or other qualified inspection agency immediately. Do not make any changes without the authorization of one of these agencies.
  • Maintain an extra stock of sprinklers and wrenches in a cabinet as required by NFPA 13.
  • Concealed sprinklers and recessed sprinklers should not be used if the space above the ceiling is used for delivery (positive pressure) in an HVAC system.
  • Globe Fire Sprinkler Corporation sprinklers have been tested, listed or approved by the agencies noted on the individual sprinkler data sheet. Acceptance by other agencies or authorities is not the responsibility of Globe Fire Sprinkler Corporation. Globe Fire Sprinkler Corporation is not liable for any costs arising as a result of any changes to listings or approvals after shipment. The Seller makes no warranties express or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose except as expressly stated in seller's sales contract or sales acknowledgment form.

Cross Sections

drytype
Ambient
Temperature of
Protected Area at the
Discharge End
of the
Sprinkler
Exposed Barrel Ambient
Temperature
40°F/4°C 50°F/10°C 60°F/16°C
Exposed Minimum Barrel Length
(Face of Tee to Top of Ceiling or Inside Wall)
40°F (4°C) 0 0 0
30°F (-1°C) 0 0 0
20°F (-7°C) 4 (101) 0 0
10°F (-12°C) 8 (203) 1 (25.1) 0
-0°F (-18°C) 12 (305) 3 (75) 0
-10°F (-23°C) 14 (356) 4 (101) 1 (25.1)
-20°F (-29°C) 14 (356) 6 (152) 3 (75)
-30°F (-34°C) 16 (406) 8 (203) 4 (101)
-40°F (-40°C) 18 (457) 8 (203) 4 (101)
-50°F (-46°C) 20 (508) 10 (254) 6 (152)
-60°F (-51°C) 20 (508) 10 (254) 6 (152)
Download this page as a pdf
Sprinklers » Caution Sheets

GL Series Bulb Spray Caution Sheet

Automatic Sprinklers GL Series Bulb Spray Caution Sheet

Installation Instructions - Read Carefully

Sprinklers

Position

Standard Orifice Upright Spray Sprinkler. Install in upright position only. Identified by "SSU" on deflector.

Standard Orifice Pendent Spray Sprinkler. Install in pendent position only. Identified by "SSP" on deflector.

Standard Orifice Conventional Spray Sprinkler. Install in upright or pendent position. Identified by "CU/P" on deflector.

Standard Orifice Horizontal Sidewall Spray Sprinkler. Install in horizontal position only. Identified by "TOP" on deflector.

Standard Orifice Vertical Sidewall Spray Sprinkler. Install in upright or pendent position. Identified by "SIDEWALL" on deflector.

Warning

Sprinklers contained in this carton have been manufactured and tested in accordance with the applicable standards or where applicable under the inspection of Underwriters Laboratories Inc., FM Approvals, and The Loss Prevention Certification Board.

Any alteration to the sprinkler after it leaves the factory including, but not limited to painting, plating, coating or other alteration, may render the sprinkler inoperative and will nullify the Listing of Underwriters Laboratories Inc., the Approval of FM Approvals, and the Approval of The Loss Prevention Certification Board.

Glass bulbs are very fragile. Handle with extreme care. Sprinklers should be kept in the carton provided with dividers at all times prior to installation. Sprinklers should never come in direct contact with one another or any other foreign object prior to installation. Do not place sprinklers in a bucket. Globe Fire Sprinkler Corporation is not responsible for glass bulb damage due to improper handling.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler
Temperatures
Bulb Color

N.F.P.A. Maximum
Ceiling Temperature

Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Green/Yellow 150°F 66°C
High 286°F 141°C Blue 225°F 107°C
Extra High 360°F 182°C Mauve 300°F 149°C

Important Precautions to Follow

  • Globe Sprinklers are to be installed in accordance with the latest published standards of the National Fire Protection Association, Factory Mutual, Loss Prevention Council, Globe Sprinkler data sheets, Government agencies and/or other similar organizations and to meet local codes and ordinances.
  • Never replace a Large Orifice Sprinkler with a standard sprinkler or vice versa.
  • Never replace a Spray Sprinkler with an old style sprinkler or a used sprinkler.
  • Never install an Upright Spray Sprinkler in a pendent position or a Pendent Spray Sprinkler in an upright position.
  • Use only a special sprinkler wrench to install sprinklers. Any other wrench is liable to injure the sprinkler.
  • Never install a sprinkler after it has dropped to the floor or been injured in any way. These sprinklers should be returned to the
    factory for examination.
  • Never install sprinklers in the fittings until the piping is in place on the ceiling as sprinklers are liable to be injured if screwed into
    the fittings when the lines are made up at the bench.
  • Never paint or whitewash sprinklers as this is liable to prevent their operation in a fire.
  • Never install sprinklers in pendent position on a dry system unless of a type designed for this purpose and as permitted by NFPA
    13 and the authority having jurisdiction.
  • Never attach wiring, ropes or fixtures to sprinkler or sprinkler piping.
  • Wax Coated, Lead Plated or Wax over Lead sprinklers should be used in all locations subject to corrosion from acid fumes,
    chemicals, processes, etc. Extreme care must be exercised when installing to avoid damage to coating.
  • Use sprinkler guards on all sprinklers subject to injury by moving objects.
  • Some Globe Fire Sprinkler Corporation sprinkler models are shipped with a factory applied sealant on the threads. Globe
    recommends that no additional tape or pipe dope be used on these sprinklers. If pipe compound is used on sprinklers without
    factory applied sealant, apply to sprinkler threads only. Wipe all excess compound off sprinkler.
  • Store sprinklers in cool, dry place and preferably in their shipping carton.
  • Sprinklers of proper rating must be carefully selected to meet the temperature conditions where they are located (see table above for available temperatures). 175°F (79°C) or lower sprinklers should not be installed in locations less than 30" above or 12" to one side of steam pipes, heating coils or radiators. 200°F (93°C) sprinkler should be used under skylights where exposed to direct sun rays. Consult the local authority having jurisdiction to determine the proper temperature ratings in special locations such as:
    • Areas near unit heaters.
    • Areas where low pressure blow-off discharges into a large room.
    • Areas in an unventilated concealed space under uninsulated wood or tin roofs.
    • Areas in an unventilated attic.
    • Areas in a shed with an unventilated peak roof or thin boards or metal.
    • Areas where show windows have high powered electric illumination processes.
    • Areas where a locomotive enters a building.
    • Areas in other locations where special consideration is necessary.
  • Inspect sprinklers regularly for mechanical damage, corrosion, paint and dust buildup as outlined in NFPA publications.
  • Standard sprinklers should be replace after 50 years of service or as conditions warrant.
  • Quick response sprinklers should be replaced after 20 years of service or as conditions warrant.
  • High temperature sprinklers (360°F and higher) should be replaced after 5 years of service or as conditions warrant.
  • When replacing sprinklers in any system, make sure those replacements are of the same style, size, and temperature rating as those removed.
  • Should a change in building structure, occupancy or temperature conditions indicate a probable change in sprinkler requirements, notify the insurance carrier or other qualified inspection agency immediately. Do not make any changes without the authorization of one of these agencies.
  • Maintain an extra stock of sprinklers and wrenches in a cabinet as required by NFPA 13.
  • Concealed sprinklers and recessed sprinklers should not be used if the space above the ceiling is used for delivery (positive pressure) in an HVAC system.
  • Globe Fire Sprinkler Corporation sprinklers have been tested, listed or approved by the agencies noted on the individual sprinkler data sheet. Acceptance by other agencies or authorities is not the responsibility of Globe Fire Sprinkler Corporation. Globe Fire Sprinkler Corporation is not liable for any costs arising as a result of any changes to listings or approvals after shipment. The seller makes no warranties express or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose except as expressly stated in seller's sales contract or sales acknowledgment form.

Download this page as a pdf
Valves & Accessories » Misc. Valves & Valve Accessories

B-20 Sight Drains

Sight Drains for Automatic Sprinkler Systems

P/NDescriptionImageCross Section
323310 1" NPT Sight Drains / 175 PSI Maximum WWP Sight Drains click for larger image
323320 2" NPT Sight Drains / 175 PSI Maximum WWP Sight Drains click for larger image

Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-5 Sprinkler Cabinets

Sprinkler Cabinets for Replacement Automatic Sprinklers

P/NDescriptionImage
312390 Six Sprinkler Cabinets for ½" OR ¾" SPRINKLER CABINET
312392 Twelve Sprinkler Cabinets for ½" OR ¾" SPRINKLER CABINET

When storing concealed sprinklers, Twelve Sprinkler Cabinet holds six units and Six Sprinkler Cabinet holds three units.

Download this page as a pdf
Sprinklers » Residential » Residential Sprinklers

A-2 5.6K Pendent Sprinkler -  GL5610

Automatic Sprinklers Model GL5610 Pendent Recessed Pendent

Description and Operation

RESIDENTIAL PENDENT & RECESSED PENDENT The Globe Model GL5610 Residential Sprinkler has a low profile yet durable design, which utilizes a 3mm frangible glass ampule as the thermosensitive element. It features economy, aesthetics and low flow.

The combination of the 3mm frangible glass ampule and specially designed deflector makes the Model GL5610 Residential Sprinkler the ultimate in life safety and fire control. This Globe Pendent and Recessed Pendent Residential Sprinkler has met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction.

The heart of Globe's Model GL5610 sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature, the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Rating - 155°F (68°C).
  • Water Working Pressure Rating - 175 psi (12 Bars).
  • Factory tested hydrostatically to 500 psi (34 Bars).
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C).
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size.
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

Classification Available Sprinkler Temperatures Bulb Color N.F.P.A. Maximum Ceiling Temperature
Ordinary 155°F 68°C Red 100°F 38°C

Specifications and Approvals

Sin
Model

'K' Factor Thread Size Length Finishes 155°F
68°C
cULus
GL5610
5.6
(80 metric)
1/2" NPT
2 1/2" (6.4 cm)

Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1

Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2C-U.L. listed corrosion resistant polyester must be specified on order.

Cross Sections

Gl5635

Installation Data for Flat and Sloped Ceilings**

Pendent and Recessed Pendent

Maximum Area of Coverage Minimum Water Discharge
& Pressures Needed*




12' x 12' 15 G.P.M. - 7.2 P.S.I.
14' x 14' 19 G.P.M. - 11.5 P.S.I.
16' x 16' 19 G.P.M. - 11.5 P.S.I.
18' x 18' 21 G.P.M. - 14.1 P.S.I.
20' x 20' 24 G.P.M. - 18.4 P.S.I.

*When these sprinklers are used in NFPA 13 systems, a 0.1 design density minimum shall be utilized.

**Refer to page 2 of the Globe Residential Sprinkler Installation Guide for NFPA 13D and 13R requirements.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390
  • Quantity - Recessed Wrenches - P/N 325391
  • Quantity - Protective Caps - P/N 327109-CAP
    (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Sprinkler Accessories

Sprinkler Wrenches

Wrenches For Globe Automatic Sprinklers

P/NDescriptionImage
325390 ½" NPT STANDARD WRENCH Wrench
312366 ¾" NPT STANDARD WRENCH Wrench
333010 ¾" NPT EXTRA LARGE ORIFICE WRENCH Wrench
337014 DRY SPRINKLER RECESSED WRENCH Wrench
325401 ¾ "NPT RECESSED WRENCH Wrench
325391 ½" NPT RECESSED / CONCEALED WRENCH Wrench
327102 RESIDENTIAL SIDEWALL RECESSED WRENCH Wrench
332765 ½” NPT 1” ADJUSTABLE CONCEALED WRENCH Wrench
332334 ½" NPT MILLENNIUM WRENCH Wrench

Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-2 Recessed Escutcheons

Globe Recessed Escutcheons

Recessed Escutcheons 1/2” NPT or 3/4” NPT

2 Pc. Recessed
(3/4” Adj. x 2 7/8” Diameter)

Finish/Part No. 1/2” NPT:
  • Chrome: 325422
  • Brass: 325424
  • *Poly: 325426
Finish/Part No. 3/4” NPT:
  • Chrome: 325423
  • Brass: 325420
  • *Poly: 325427

2 Pc. Recessed
(1/2” Adj. x 2 7/8” Diameter)

Finish/Part No. 1/2”NPT:

  • Chrome: 332071
  • Brass: 332072
  • *Poly: 332073

2 Pc. Screw Adjustable Recessed
(3/4” Adj. x 2 7/8” Diameter)

Finish/Part No. 1/2” NPT:
  • Chrome: 329306
  • *Poly: 329308
Finish/Part No. 3/4” NPT:
  • Chrome: 325423
  • Brass: 325420
  • *Poly: 325427

2 Pc. Screw Adjustable Recessed
(1/2” Adj. x 2 7/8” Diameter)

Finish/Part No. 1/2” NPT:
  • Chrome: 329301
  • *Poly: 329303
Finish/Part No. 3/4” NPT:
  • Chrome: 329311
  • *Poly: 329313

1/2” Adjustable Recessed Model Numbers

  • cULus Approved: 2810, 4110, 4210, 4230, 4231, 4234, 4710, 5628, 5630, 5631, 8101, 8107, 8128, 8129, 8151 & 8174
  • cULus & FM Approved: 5601, 8106 & 8156

3/4” Adjustable Recessed Model Numbers

  • cULus Approved: 2801, 2826, 2851, 2870, 4201, 4226, 4231, 4251, 4270, 5601, 5602, 5626, 5628, 5635, 5636, 5641, 5642, 5652, 5670, 5679, 5680, 5685, 5686, 8101, 8102, 8151, 8152 , 8106, 8107, 8109, 8127, 8128, 8129, 8135, 8141, 8157, 8159, 8171, 8174, 8179, 8185
  • cULus & FM Approved: 5651 & 8156
*When ordering specify color after part number: -W= white, -B= black.

Download this page as a pdf
Valves & Accessories » System Sensor

Alarm Pressure Switches - EPS10-1 & EPS10-2

EPS10-1 and EPS10-2 Alarm Pressure Switches

Product Overview

Alarm Pressure Switches
  • Sensitivity adjustment wheel, no tools required
  • Reinforced diaphram resists pressure spikes
  • Two conduit entrances provided
  • NEMA 4 rated

System Sensor EPS10 Series switches are designed for use in wet, dry, deluge, and preaction automatic sprinkler systems to indicate a discharge from a sprinkler. The EPS10-1 has a single SPDT switch while the EPS10-2 model contains two SPDT switches..

The EPS10 Series features field adjustable pressure sensitivity to provide an alarm response between 4 and 20 psi. It is factory set to respond at 4 – 8 psi on rising pressure. The pressure adjustment wheel requires no special tools and does not affect switch synchronization on the EPS10-2.

Specifications

Standard Specifications
Maximum Operating Pressure
250 psi
Differential
Approximately 3 psi throughout range
Maximum Adjustment Pressure Range
4 to 20 psi
Factory Setting
Operates at rising pressure 4 to 8 psi
Pressure Connection
1/2" NPT male glass reinforced nylon
Switch Contact Ratings
EPS10-1: One set SPDT (Form C)
EPS10-2: Two sets SPDT (Form C)
10.0 A, 1/2 HP @ 125/250 VAC
2.5 A @ 6/12/24 VDC
Dimensions
5.12" H x 3.325" W x 4.250" L
(13.0 cm x 8.4 cm x 10.8 cm)
Operating Temperature Range:
Indoor or outdoor use
–40°F to 160 °F ( –40°C to 71°C)
Cover Tamper Switch
UL Models: Optional P/N 546-8000
ULC Models: Factory Installed
Enclosure
Rated UL 4x, NEMA 4 for indoor or outdoor use
Shipping Weight
1.2 lbs. (.54 Kg)
Service Use
Automatic Sprinkler: NFPA 13
One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 Stories: NFPA 13R
National Fire Alarm Code: NFPA 72
Warranty
3 years

Engineering Specifications

ApprovalsModel shall be an EPS10-1 or EPS10-2 pressure type waterflow switch as manufactured by System Sensor of St. Charles, IL. They shall be installed on the sprinkler system with connection as shown on the drawings and/or as specified herein. Pressure switches shall be of the bellows-activated type.

Switches shall have a maximum service pressure rating of 250 psi and shall be factory adjusted to operate at a pressure of 4 – 8 psi. There shall be one (1) or two (2) SPDT contacts rated at 10.0 Amp @ 125/250 VAC and 2.5 Amp @ 6/12/24 VDC.

The contractor shall furnish and install, where indicated on the plans, pressure switches according to appropriate NFPA standards. Switches shall be provided with a 1⁄2" NPT male pressure connection to be connected to the alarm check valve of a “wet” sprinkler system, into the intermediate chamber of a “dry” system, or to a pre-action or deluge valve. They shall be activated by any flow of water equal to or in excess of the discharge from one sprinkler head. Switches shall provide 1 knockout type and 1 open hole for 1⁄2" conduit fitting attachment and a ground screw provision for electrical grounding.

The switch enclosure shall be weatherproof and carry a UL 4x/NEMA 4 rating when used with proper electrical fittings and conduit. The cover shall incorporate tamper-resistant screws.

The unit shall be listed by Underwriters Laboratories, Inc. and approved by Factory Mutual.

Cross Section




Ordering Information

Model Number Description
EPS10-1
Alarm Water flow Pressure Switch, One SPDT, 4 –20 PSI
EPS10-2
Alarm Water flow Pressure Switch, Two SPDT, 4 –20 PSI
EPSA10-1
ULC/Canadian Version
EPSA10-2
ULC/Canadian Version

Replacement Parts Description
S07-66-02
Replacement Tamper Screws for Cover of EPS
WFDW
Replacement Tamper Proof Wrench for Cover of EPS
546-8000
Cover Tamper Switch for EPS Series

Download this page as a pdf
Valves & Accessories » System Sensor

Supervisory Special Purpose Switch - PSP1

PSPI Plug-in Special Purpose Supervisory Switch

Product Overview

PSPI Plug-in Special Purpose Supervisory Switch
  • Monitors non-rising stem gate and ball and angle valves
  • NEMA 3 rated enclosures
  • 360° mounting design provides greater installation flexibility
  • Adjustable length supervisory cord
  • Lockout feature ensures alarm signal integrity
  • Cover tamper switch factory installed
  • Tamper-resistant cover screws

System Sensor’s PSP1 plug-in switch is a special application supervisory switch designed for applications where no other type of listed valve supervisory switch can be used..

Application Flexibility. The PSP1 is to be used on non-rising stem gate valves and ball and angle valves. The unit is approved for Class A and Class B circuits.

Robust Construction. The PSP1 consists of a rugged rain tight metal housing. With its NEMA 3 rated housing and water-resistant cord, the PSP1 may be used in either indoor or outdoor applications.

Simplified Operation. The PSP1 features a 360° versatile mounting design and an adjustable length cord which allow more freedom to install the unit at the most desirable alignment angle.

Reliable Performance. The PSP1 employs a supervisory cord which, when pulled out, closes a set of normally open contacts. A lockout feature prevents reinsertion of the cord until the cover is removed, and the unit is reset. Removal of the cover or cutting of the cord results in an open circuit.

Specifications

Standard Specifications
Operating Voltage
6/12/24V AC/DC
Maximum Operating Current
250 mA
Dimensions
43/4"L x 3"W x 21/2"D
(12cm x 7.5cm x 5.6cm)
Dimensions with bracket
81/2"L (21.5cm)
Operating Temperature Range
-4°F to 149 °F (-20 °C to 65°C)
Enclosure Rating
NEMA 3 UL Indoor/Outdoor Rated
Cover Tamper Switch
Standard
Cable
2 wire, 16 gauge waterproof, 8 feet long (2.4m)
Shipping Weight
1.7 lbs. (0.8 kg)
Warranty
3 years

Engineering Specifications

ApprovalsModel shall be a model number PSP1 special purpose supervisory switch as manufactured by System Sensor. The unit is not intended or designed for ordinary usage. It is a special application device to be used for unusual conditions where no other approved or listed method of protection is available or practical, such as non-rising stem gate valves. When installed on a non-rising stem gate valve, turning the valve wheel will pull the plug out of the jack and close a set of normally open contacts. A lockout will prevent reinsertion and will require removal of the cover. Tamper-proof screws are provided for the cover. Removal of the cover, cutting of the cord, or ground faults will cause an open circuit. The device should be wired to the trouble circuit of a fire alarm control panel. The PSP1 shall be capable of operating on Class A or Class B circuits. The PSP1 shall be NEMA 3 rated for indoor/outdoor use and shall have an operating temperature range of - 4°F to 149°F (- 20°C to 65°C). The PSP1 shall be listed by Underwriters Laboratories and Underwriters Laboratories of Canada, Inc. and shall be Factory Mutual approved.

Cross Sections


Ordering Information

Model Number Description
PSP1
Plug-In Special Purpose Supervisory Switch
PSP1A
Plug-In Special Purpose Supervisory Switch (ULC model)

Valves & Accessories » System Sensor

Supervisory Pressure Switches - EPS40-1 & EPS40-2

EPS40-1 and EPS40-2 Supervisory Pressure Switches

Product Overview

WFD Series Waterflow Detector
  • Sensitivity adjustment wheel, no special tools required
  • Reinforced diaphram resists pressure spikes
  • Two conduit entrances provided
  • NEMA 4 rated

System Sensor EPS40 Series switches are designed for use in dry pipe systems or pressure tanks and water pressure supplies of automatic water control valves. The EPS40-1 has a single SPDT switch while the EPS40-2 model contains two SPDT switches.

WFD Series Waterflow DetectorThe EPS40 Series features field adjustable pressure sensitivity to provide an alarm response between 10 and 100 psi. All models are factory set for use in a nominal 40 psi system. The EPS40-1 is factory set to respond at 30 psi at decreasing pressure while the EPS40-2 is factory set to respond at 50 psi on rising pressure and 30 psi at decreasing pressure. The pressure adjustment wheel requires no special tools and does not affect switch synchronization on the EPS40-2..

Specifications

Standard Specifications
Maximum Operating Pressure
250 psi
Differential
Approximately 3 psi @ 10 psi, 6 psi @ 100 psi
Maximum Adjustment Pressure Range
10 to 100 psi
Factory Setting
EPS40-1 operates at decreasing pressure at 30 psi
EPS40-2 operates at increasing pressure at 50 psi
and decreasing pressure at 30 psi
Pressure Connection
1/2" NPT male
Switch Contact Ratings
EPS40-1: One set SPDT (Form C)
EPS40-2: Two sets SPDT (Form C)
10.0 A, 1/2 HP @ 125/250 VAC
2.5 A @ 6/12/24 VDC
Dimensions
5.12" H x 3.325" W x 4.250" L
(13.0 cm x 8.4 cm x 10.8 cm)
Operating Temperature Range:
Indoor or outdoor use
–40°F to 160 °F ( –40°C to 71°C)
Cover Tamper Switch
UL Models: Optional P/N 546-8000
ULC Models: Factory Installed
Enclosure
Rated UL 4x, NEMA 4 for indoor or outdoor use
Shipping Weight
1.2 lbs. (.54 Kg)
Service Use
Automatic Sprinkler: NFPA 13
One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 Stories: NFPA 13R
National Fire Alarm Code: NFPA 72
Warranty
3 years

Engineering Specifications

ApprovalsModel shall be an EPS40-1 or EPS40-2 pressure type waterflow switch as manufactured by System Sensor of St. Charles, IL. They shall be installed on the sprinkler system with connection as shown on the drawings and/or as specified herein. Pressure switches shall be of the bellows-activated type.

Switches shall have a maximum service pressure rating of 250 psi and shall be adjustable from 10 - 100 psi. There shall be one (1) or two (2) SPDT contacts rated at 10.0 Amp @ 125/250 VAC and 2.5 Amp @ 6/12/24 VDC.

The contractor shall furnish and install, where indicated on the plans, pressure switches according to appropriate NFPA standards. Switches shall be provided with a 1⁄2" NPT male pressure connection to be connected into the air supply line on the system side of any shut-off valve. Switches shall provide 1 knockout type and 1 open hole for 1⁄2" conduit fitting attachment and a ground screw provision for electrical grounding.

The switch enclosure shall be weatherproof and carry a UL 4x/NEMA 4 rating when used with proper electrical fittings and conduit. The cover shall incorporate tamper-resistant screws.

The unit shall be listed by Underwriters Laboratories, Inc., the California State Fire Marshal, MEA, and approved by Factory Mutual.

Cross Section




Ordering Information

Model Number Description
EPS40-1
Low Pressure Supervisory Switch, One SPDT, 10-100 PSI
EPS40-2
High/Low Pressure Supervisory Switch, Two SPDT, 10-100 PSI
EPSA40-1
ULC/Canadian Version
EPSA40-2
ULC/Canadian Version

Replacement Parts Description
S07-66-XX
Replacement Tamper Screws for Cover of EPS
WFDW
Replacement Tamper Proof Wrench for Cover of EPS
546-8000
Cover Tamper Switch for EPS Series

Download this page as a pdf
Valves & Accessories » System Sensor

Supervisory Switch - PIBV2

PIBV2 Supervisory Switch

Product Overview

WFD Series Waterflow Detector
  • NEMA 3R rated enclosure
  • Bi-directional actuator accommodates rising or falling flags
  • Single side conduit entry does not require right angle fittings
  • Adjustable length actuator eliminates the need for cutting the shaft
  • Accommodates up to 12 AWG wire
  • Two SPDT contacts are enclosed in a durable terminal block for added strength
  • 100% synchronization activates both alarm panel and local bell simultaneously

System Sensor’s PIBV2 supervisory switch monitors the open position of post indicator and butterfly control valves.

Robust Construction. The PIBV2 consists of a rugged housing, intended for indoor and outdoor use. When installed with the actuator in the vertical position, the PIBV2 is NEMA 3R rated per UL.

Application Flexibility. The PIBV2 features a flexible design that accommodates post indicator, butterfly, and many other types of wall post, recessed wall post and pressure reducing valves. The PIBV2’s unique bi-directional actuator allows the unit to be installed in either rising or falling flag installations.

Simplified Operation. Installation is made easier with the PIBV2’s single side conduit entrance. By providing a direct conduit pathway to the electrical source, right angle fittings are not required. Installation is further simplified by the PIBV2’s adjustable length actuator, which eliminates the need for cutting the shaft.

Reliable Performance. The PIBV2 is equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance.

Specifications

Standard Specifications
Contact Ratings
Two sets of SPDT (Form C)
10.0 A @ 125/250V AC
2.5 @ 6/12/24V DC
Overall Switch Dimensions
41/4″H x 31/2″W x 31/4″D
(10.8cm x 8.9cm x 8.2cm)
Maximum Stem Extension
21/8″ (5.4 cm)
Mounting
1/2″ NPT nipple
Conduit Entrances
One single side open for 1/2″ conduit
Operating Temperature Range
32°F to 120°F (0°C to 49°C)
Note: The PIBV2 will operate from –40°F to 120°F
(–40°C to 49°C); however UL does not test control
valve supervisory switches below 32°F (0°C).
Enclosure Rating
UL indoor/outdoor
NEMA 3R when mounted with the actuator vertical
Cover Tamper Switch
Standard with ULC model
Optional for UL model, part no. 546-7000
Shipping Weight
2 lbs. (0.9 kg)
Service Use
Automatic Sprinkler: NFPA 13
One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 stories: NFPA 13R
National Fire Alarm code: NFPA 72
Warranty
3 years
U.S. Patent No.
5,213,205

Engineering Specifications

Model shall be model number PIBV2 Post Indicator Butterfly Valve supervisory switch as manufactured by System Sensor. PIBV2 shall be installed on each valve as designated on the drawings and/or as specified herein. Switches shall be mounted so as not to interfere with the normal operation of the valve and shall be adjusted to operate within two revolutions of the valve control or when the valve flag has moved no more than one-fifth of the distance from its normal position. The mechanism shall be contained in a weatherproof die cast metal housing, which shall provide a side entrance for 1/2″ conduit and incorporate a 1/2″ NPT nipple for attachment to the valve body. A grounding provision is provided. The switch assembly shall include two switches each with a rated capacity of 10 Amp @ 125/250V AC and 2.5 Amp @ 24V DC. The cover shall contain tamper-resistant screws for which a security wrench will be provided with each switch. PIBV2 shall be Underwriters Laboratories listed for indoor or outdoor use. The PIBV2 shall be Factory Mutual, CSFM, and MEA approved.

Cross Section


Ordering Information

Model Number Description
PIBV2
Post Indicator/Butterfly valve supervisory switch
PIBV2A
Post Indicator/Butterfly valve supervisory switch (ULC model)
Part Number Description
A3010-00
Replacement hardware kit (wrenches, screw pack)
546-7000
Cover tamper switch kit
S07-66-XX
Tamper screws for cover
WFDW
Replacement tamper proof wrench for cover
HEXW
Replacement hex wrench

Models Available
 
Replacement Parts
PIBV2
Post Indicator/Butterfly
Valve Supervisory Switch
  A3010-00
Replacement Hardware Kit
PIBV2A
Post Indicator/Butterfly
Valve Supervisory Switch
(ULC/Canadian)
  546-7000
Cover Tamper Switch Kit
      S07-66-XX
Cover Tamper Switch Kit
      WFDW
Cover Wrench
      HEXW
Replacement Hex Wrench

Download this page as a pdf
Valves & Accessories » System Sensor

Supervisory Switch - OSY2

OSY2 Supervisory Switch

Product Overview

WFD Series Waterflow Detector
  • NEMA 3R rated enclosure
  • User-friendly mounting bracket fits newer valve yokes
  • Single side conduit entry does not require right angle fittings
  • Adjustable length actuator eliminates the need for cutting the shaft
  • Accommodates up to 12 AWG wire
  • Three position switch monitors vandal and valve close signals
  • Two SPDT contacts are enclosed in a durable terminal block for added strength
  • 100% synchronization activates both alarm panel and local bell simultaneously

System Sensor’s OSY2 is used to monitor the open position of an Outside Screw and Yoke (OS&Y) type gate valve.

Robust Construction. The OSY2 consists of a rugged housing, intended for indoor and outdoor use. When installed with the actuator in the vertical position, the OSY2 is NEMA 3R rated per UL.

Application Flexibility. The OSY2 features a user-friendly mounting bracket and adjustable shaft to permit mounting to most OS&Y valves, ranging is size from 1″ to 12″. Its right angle design and wide bracket span provides maximum clearance for valve components, to accommodate troublesome valves. Removing the OSY2’s gate valve bracket allows the unit to monitor sidebracket style pressure reducing valves.

Simplified Operation. Installation is made easier with the OSY2’s single side conduit entrance. By providing a direct conduit pathway to the electrical source, right angle fittings are not required. Installation is further simplified by the OSY2’s adjustable length actuator, which eliminates the need for cutting the shaft.

Reliable Performance. The OSY2 is equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal black to assure reliable performance.

Specifications

Standard Specifications
Contact Ratings
Two sets of SPDT (Form C)
10.0 A @ 125/250V AC
2.5 @ 6/12/24V DC
Overall Switch Dimensions
5¾″H x 3½″W x 3¼″D
(14.6cm x 8.9cm x 8.2cm)
Bracket Span
2¼″H x 6¾″W x 1″D
(5.7cm x 17.1cm x 2.5cm)
Maximum Stem Extension
25/8″ (6.7 cm)
Shipping Weight
2.8 lbs. (1.3 kg)
Conduit Entrances
One single side open for ½″ conduit
Operating Temperature Range
32°F to 120°F (0°C to 49°C)
Note: The OSY2 will operate from –40°F to 120°F
(–40°C to 49°C); however UL does not test control valve supervisory switches below 32°F (0°C).
Enclosure Rating
UL indoor/outdoor
NEMA 3R when mounted with the actuator vertical
Cover Tamper Switch
Standard with ULC model
Optional for UL model, part no. 546-7000
Service Use
Automatic Sprinkler: NFPA 13
One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 stories: NFPA 13R
National Fire Alarm code: NFPA 72
Warranty
3 years
U.S. Patent Numbers
5,478,038; 5,213,205

Engineering Specifications

Model shall be model number OSY2 supervisory switch as manufactured by System Sensor. OSY2 shall be installed on each valve as designated on the drawings and/or as specified herein. Switches shall be mounted so as not to interfere with the normal operation of the valve and shall be adjusted to operate within two revolutions of the valve control or when the stem has moved no more than one-fifth of the distance from its normal position. The mechanism shall be contained in a weatherproof die cast metal housing, which shall provide a side entrance for 1/2″ conduit and incorporate the necessary facilities for attachment to the valve. A grounding provision is provided. The switch assembly shall include two switches each with a rated capacity of 10 Amp @ 125/250VAC and 2.5 Amp @ 24VDC. The cover shall contain tamper-resistant screws for which a security wrench will be provided with each switch. The OSY2 shall be Underwriters Laboratories listed for indoor or outdoor use. The OSY2 shall be Factory Mutual, CSFM, and MEA approved.

Cross Sections


Ordering Information

Model Number Description
OSY2
Outside Screw and Yoke valve supervisory switch
OSY2A
Outside Screw and Yoke valve supervisory switch (ULC model
Part Number Description
OSYRK
Replacement hardware kit (wrenches, screw pack and J-hooks)
546-7000
Cover tamper switch kit
S07-66-XX
Tamper screws for cover
WFDW
Replacement tamper proof wrench for cover
HEXW
Replacement hex wrench

Models Available
 
Replacement Parts
OSY2 OS&Y Supervisory Switch   OSYRK Replacement Hardware Kit
OSY2A OS&Y Supervisory Switch
(ULC/Canadian)
  546-7000 Cover Tamper Switch Kit
      S07-66-XX Tamper Screws for Cover
      WFDW Cover Wrench
      HEXW Replacement Hex Wrench

Download this page as a pdf
Valves & Accessories » System Sensor

Alarm Bells - SSM/SSV

SSM/SSV Series Alarm Bells

Product Overview

SSM/SSV Series Alarm Bells

Approved for indoor and outdoor use

Low current draw

High dB output

Three sizes available 6", 8", 10"

AC and DC models

DC models are polarized for use with supervision circuitry

Mount directly to standard 4" square electrical box

System Sensor’s SSM and SSV series bells are low current, high decibel notification appliances for use in fire and burglary systems or other signaling applications.

Reliable Performance. The SSM and SSV series provide loud resonant tones. The SSM series operate on 24VDC and are motor driven, while the SSV series operate on 120VAC utilizing a vibrating mechanism.

Simplified Installation. For indoor use, the SSM and SSV series mount to a standard 4 inch square electrical box. For outdoor applications, weatherproof back box, model number WBB, is used.

The SSM and SSV series come pre-wired, to reduce installation time. The SSM series incorporate a polarized electrical design for use with supervision circuitry.

Specifications

Standard Specifications
Operating Temperature Range
-31°F to 140 °F
Operating Voltage
SSM series 24VDC
SSV series 120VAC
Termination
Provided with 2 sets of leads for
in/out writing
Service Use
Fire Alarm, General Signaling, Burglar Alarm
Warranty
3 years

Model Gong Diameter
(inches)
Nominal Voltage Operating
Voltage Range
Average
Current Draw
Sound Output (dB)
SSM24-6 6 24VDC 19.2 to 26.4VDC 0.03A 85
SSM24-8 8 85
SSM24-10 10 85
SSV120-6 6 120VAC 96 to 132VAC 0.047A 82
SSV120-8 8 85
SSV120-10 10 82
* Sound output measured at Underwriter Laboratories, as specified in UL464

Engineering Specifications

ApprovalsModel shall be a SSM or SSV Series alarm bell. Bells shall have underdome strikers and operating mechanisms. Gongs on said bells shall be no smaller than nominal 6"/8"/10" (specify size) with an operating voltage of 24VDC or 120VAC (specify by part number). Bells shall be suitable for surface or semi-flush mounting. Outdoor surface mounted installations shall be weatherproof (using optional WBB weatherproof electrical box). Otherwise bells shall mount to a standard 4" square electrical box having a maximum projection of 21/2". Bells shall be located as shown on the drawings or as determined by the Authority Having Jurisdiction. Bells shall be listed for indoor/outdoor use by Underwriters Laboratories and the California State Fire Marshal, and approved by Factory Mutual and MEA.

Ordering Information

UL/FM Model Numbers ULC/Canadian Models Description
SSM24-6 SSM24-6A Bell, 6", 24VDC, Polarized, 85dba
SSM24-8 SSM24-8A Bell, 8", 24VDC, Polarized, 85dba
SSM24-10 SSM24-10A Bell, 10", 24VDC, Polarized, 85dba
SSV120-6 SSV120-6A Bell, 6", 120VAC, 82dba
SSV120-8 SSV120-8A Bell, 8", 120VAC, 85dba
SSV120-10 SSV120-10A Bell, 10", 120VAC, 82dba
WBB   Weatherproof Back Box for SSM and SSV series,
when installed outdoor

UL/FM Models ULC/Canadian Models Weatherproof Back Box
SSM24-6
SSM24-6A
WBB
SSM24-8
SSM24-8A
 
SSM24-10
SSM24-10A
 
SSV120-6
SSV120-6A
 
SSV120-8
SSV120-8A
 
SSV120-10 SSV120-10A  


Download this page as a pdf
Valves & Accessories » System Sensor

T-Tap Waterflow Detector

T-Tap Waterflow Detector

Product Overview

WFD Series Waterflow Detector

Sealed retard mechanism (Model WFDT) assures that the retard is not contaminated by dust and dirt when the cover is removed

Visual Switch Activation (Model WFDT) permits installer to accurately set the retard even under extremely noisy conditions

100% Synchronization activates both alarm panel and local bell simultaneously

Accommodates up to 12 AWG wire

System Sensor WFDT Retard and WFDTNR Non-Retard T-Tap Waterflow Detectors are designed for primary signaling in residential systems and branch line signaling in larger systems. Both models fit any tee that has a 1″ NPT branch, including: 1″, 11⁄4″ and 11⁄2″ NPT threaded ferrous and brass tees; 1″, 11⁄4″, 11⁄2″ and 2″ copper sweat tees; Central, Spears®, and Victaulic® brand 1″ CPVC tees; and 11⁄2″ polybutylene tees.

Design. The design of the WFDT and WFDTNR makes them easy to install and simple to maintain. Either can be mounted in the vertical or horizontal position. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism (Model WFDT only) and switch assemblies are fieldreplaceable.

Features. Nine different flexible plastic paddles fit 1″, 11⁄4″, 11⁄2″ and 2″ tees. Sizes are marked clearly on the paddle for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw. The handy depth gauge insures the proper installation depth and clearance of the detector to the tee.

Construction. The WFDT and WFDTNR include a durable tamper resistant enclosure and rugged switch assembly. The long lasting covers completely enclose the electrical components to keep out dust and dirt. Improved self-guiding security screws and removal tools make detectors resistant to tampering and simplify field maintenance. Dual SPDT switches are enclosed in a durable terminal block for added strength.

Specifications

General Specifications
Static Pressure Rating
250 PSI
Triggering Threshold Bandwidth
(Flow Rate)
4 – 10 GPM
Maximum Surge
18 FPS
Compatible Tee Fittings
Threaded ferrous and brass tees, copper sweat tees, CPVC tees, and polybutylene tees
Contact Ratings
Two sets of SPDT (Form C)
10.0 A @ 125/250 VAC
2.5 A @ 24 VDC
Overall Dimensions, Installed
WFDT: 4.5″ H x 3.75″ W x 6.7″ L
(11.4cm H x 9.5cm W x 17cm L)
WFDTNR: 3.75″ H x 3.25″ W x 4.25″ L
(9.5cm H x 8.2cm x W x 10.8cm L)
Conduit Entrances
2 openings for 1⁄2″ conduit
Operating Temperature Range
32°F – 120°F (0°C – 49°C)
Enclosure Rating
UL Indoor/Outdoor Rated
Shipping Weight
WFDT: 2.6 lbs. (1.2 kg.)
WFDTNR: 1.5 lbs. (0.7 kg.)
Service Use
Automatic Sprinkler: NFPA 13
One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 Stories: NFPA 13R
National Fire Alarm Code: NFPA 72
Warranty
3 years
U.S. Patent Numbers
3,845,259; 4,782,333; 5,213,205

Engineering Specifications

Model shall be a WFDT or WFDTNR as manufactured by System Sensor. T-tap water flow detectors shall be installed on a tee that has a 1″ NPT branch including: 1″, 11⁄4″ , or 11⁄2″ threaded ferrous or brass tee; 1–2″ copper sweat tees; Central, Spears®, and Victaulic® brand 1″ CPVC tees; or 11⁄2″ polybutylene tee as designated on the drawings and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate size, either a ver tical or horizontal run at least 6″ from any fittings or valves which may change water direction, flow rate, or pipe diameter or no closer than 24″ from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 250 psi. The retard t-tap detector shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through the tee fitting and connected by a mechanical linkage to the delay mechanism. The non-retard t-tap detector shall respond with no time delay to waterflow in the specified direction and range. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances (one of which is a knockout type) for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. All detectors shall be listed by Underwriters Laboratories for indoor or outdoor use.

Cross Section

Electrical Connections for WFDT
Common and B connections will close when vane is deflected, i.e., when water is flowing. Dual switches permit applications to be combined on a single detector.
Contact Ratings
125/250 VAC 10 AMPS
24 VDC 2.5 AMPS




Break wire as shown for supervision of connection. Do not allow stripped wire leads to extend beyond switch housing. Do Not loop wires.

Click image above for a detailed view of this product

Ordering Information

Part Number Description
WFDT
Waterflow Detector, Fits 1″, 11⁄4″, 11⁄2″ ferrous and brass threaded tees;
1″, 11⁄4″, 11⁄2″, 2″ copper sweat tees; 1″ CPVC tees;and 11⁄2″ polybutylene tees
WFDTNR
Waterflow Detector, non-retard, fits same tees as Model WFDT
A77-01-02
Replacement Terminal Block for WFDT
A77-01-08
Replacement Terminal Block for WFDTNR
A3008-00
Replacement Retard Mechanism
PRK9
Replacement Paddle Kit — 11 paddles for WFDT and WFDTNR (see WFDT for sizes)
546-7000
Cover Tamper Switch Kit for WFDT
S07-66-02
Replacement Tamper Screws for Covers of WFDT, WFDTNR
WFDW
Replacement Tamper Proof Wrench for Cover of WFDT, WFDTNR
WFDN4
NEMA-4 Gasket Kit
C58-164-01
Replacement Metal Cover

Models Available
 
Replacement Parts
WFDT Waterflow Detector   A77-01-02 Terminal Block for WFDT
WFDTA Waterflow Detector
(ULC/Canadian)
  A77-01-08 Terminal Block for WFDTNR
WFDTNR Waterflow Detector
(non-retard)
  A3008-00 Retard Mechanism
      PRK9 Paddle Kit
      546-7000 Cover Tamper Switch Kit
      S07-66-02 Tamper Screws for Cover
      WFDW Cover Wrench
      WFDN4 NEMA-4 Gasket Kit
      C58-164-01 Metal Cover

Download this page as a pdf
Valves & Accessories » System Sensor

WFD Series Waterflow Detector

WFD Series Waterflow Detector

Product Overview

WFD Series Waterflow Detector

New WFD30-2 models install in 2” hole sizes.

UL models are NEMA 4 rated

Sealed retard mechanism assures that the retard is not contaminated by dust and dirt when the cover is removed

Visual switch activation permits installer to accurately set retard under noisy conditions

Rugged, dual SPDT switches are enclosed in a durable terminal block

Accommodates up to 12 AWG wire

100% synchronization activates both alarm panel and local bell simultaneously

System Sensor’s WFD series is compatible with schedule 10 through 40 steel pipe, sizes 2” through 8”, and can be mounted in a vertical or horizontal position.

Robust Construction. The WFD series consists of a rugged, NEMA 4 rated enclosure. Designed for both indoor and outdoor use, the WFD series operates across a wide temperature range, from 32°F to 120°F.

Reliable Performance. UL listed models are equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets of SPDT (Form C) synchronized switches are enclosed in a durable terminal block to assure reliable performance.

False Alarm Immunity. The WFD series incorporates a mechanical retard feature, which minimizes the risk of false alarm due to pressure surges or air trapped in the sprinkler system. In addition, the mechanical retard’s unique sealed design is immune to dust and other contaminants.

Simplified Operation. The WFD series is designed to simplify installation. Two conduit openings permit easy attachment to the local alarm system. The retard mechanism and dual SPDT switches are field-replaceable.

Specifications

Engineering Specifications

ApprovalsVane-type waterflow detectors shall be installed on system piping as designated on the drawing and/or as specified herein. Detectors shall mount on any clear pipe span of the appropriate nominal size, either a vertical upflow or horizontal run, at least 6” from any fittings which may change water direction, flow rate, or pipe diameter or no closer than 24” from a valve or drain. Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi for 2” - 8” pipes. The detector shall respond to waterflow in the specified direction after a preset time delay which is field adjustable. The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation. The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism. Outputs shall consist of dual SPDT switches (Form C contacts). Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided. Unless noted, enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc. All detectors shall be listed by Underwriters Laboratories Inc. for indoor or outdoor use.

Standard Specifications
Static Pressure Rating
450 PSI
Triggering Threshold Bandwidth
(Flow Rate)
4-10 GPM
Maximum Surge
18 Feet Per Second (FPS)
Compatible Pipe:
Steel water pipe, schedule 10 through 40
Contact Ratings
Two sets of SPDT (Form C)
10.0 A, 1/2 HP @ 125/250 VAC
2.5 A @ 6/12/24 VDC
Conduit Entrances
Two openings for 1/2” conduit. One open, one knock-out type
Operating Temperature Range
32ºF to 120ºF (0ºC to 49ºC)
Enclosure Rating*
NEMA 4 - suitable for indoor/outdoor use
Cover Tamper Switch
Standard with ULC models
Optional for UL models, part no. 546-7000
Shipping Weight
WFD20: 4.2 lbs., WFD25: 4.3 lbs., WFD30: 4.5 lbs., WFD30-2: 4.5 lbs., WFD35: 4.7 lbs., WFD40: 5.2 lbs., WFD50: 6.3 lbs. WFD60: 6.8 lbs., WFD80: 7.5 lbs.
Service Use
Automatic Sprinkler: NFPA-13
One or Two Family Dwelling: NFPA 13D
Residential Occupancies up to 4 Stories: NFPA 13R
National Fire Alarm Code: NFPA-72
Warranty
3 Years
U.S. Patent Numbers
3,845,259    4,782,333    5,213,205

Cross Section

Overall Dimensions Installed:

Click image above for a detailed view of this product

Ordering Information

Part Number Description
A3008-00 Retard mechanism
A77-01-02 Terminal block
546-7000 Tamper proof switch kit
546-7000 Tamer proof wrench for cover
WFDN4 Gasket kit

UL Model
Numbers
ULC/Canadian
Model Numbers
Pipe Size Hole Size
WFD20 WFD20A 2" 1¼"
WFD25 WFD25A 2½" 1¼"
WFD30 WFD30A 3" 1¼"
WFD30-2* WFD30-2A 3" 2"
WFD35 WFD35A 3½" 1¼"
WFD40 WFD40A 4" 2"
WFD50 WFD50A 5" 2"
WFD60 WFD60A 6" 2"
WFD80 WFD80A 8" 2"
*UL listed only.
UL Models
ULC/Canadian Models  
Replacement Parts
WFD20 WFD20A   A3008-00 Retard Mechanism
WFD25 WFD25A
  A77-01-02 Terminal Block
WFD30 WFD30A   546-7000 Cover Tamper Switch Kit
WFD30-2 WFD30-2A   WFDW Cover Wrench
WFD35 WFD35A   WFDN4 Replacement gasket kit
WFD40 WFD40A      
WFD50 WFD50A      
WFD60 WFD60A      
WFD80 WFD80A      


Download this page as a pdf
Valves & Accessories » Misc. Valves & Valve Accessories

Inspectors Test & Drain Valve

Inspectors Test & Drain Valve

Features

Inspectors Test and Drain Valve
  • Positive positioning of handle for off, test, or drain
  • Only 2 threaded connections
  • Integral Sight Glass
  • May be installed in horizontal or vertical position
  • Available test orifice sizes 1/2" and 17/32"
  • Available in 1” NPT or 1¼" NPT

Approvals

  • UL
  • FM

Cross Section

larger image

Valve
Size
Take
Out
ABCWeightOrificeP/N
1" 4" 2 ½" 8¼" 4 ½" 3.2 lbs. ½" 324067
1¼" 4" 2 ½" 8¼" 4 ½" 3.2 lbs. ½" 324066

Download this page as a pdf
Valves & Accessories » Butterfly Valves

GLR300W Wafer Type Butterfly Valves

GLR300W Wafer Type Butterfly Valves Wafer Type End, Sizes: 2 ½", 3", 4", 6" and 8"

Specifications

Bronze butterfly Valves
  • Working Pressure: 300 PSI (21.4 Bars)
  • Max. Test Pressure: 600 PSI (42.8 Bars)
  • Max. Working Temp: 250°F (120°C)

Factory installed UL Listed Double Tamper Switch For Indoor and Outdoor Use.

Materials of Primary Components
Body ASTM A-536 Nylon-11 Coated
Disc ASTM A-536 EPDM
Encapsulated
Upper and Lower Stems AISI 420-SS
Worm Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag Indicator ASTM A-536
Sheer Pin ASTM A-510
Segment Gear ASTM B-148 or B-584
Housing Gasket EPDM Grade "E"
O-Rings (All) EPDM Grade "E"
 

Approvals

  • NYC - DOB MEA Approved 155-06-E
  • cULus Listed
  • FM Approved (except 8")

Cross Section

larger image

Click image above for a detailed view of this product.

Dimension            Unit: in(mm)
Size A B C D E P/N
2 ½" 6.54 (166) 5.31 (135) 5.35 (136) 3.43 (87) 1.81 (46) 311836-G
3" 6.81 (173) 5.31 (135) 5.63(143) 3.66 (93) 1.81 (46) 311839-G
4" 7.32 (186) 5.31 (135) 6.14 (156) 4.29 (109) 2.05 (52) 311846-G
6" 8.58 (218) 8.66 (193) 7.40 (188) 5.67 (144) 2.20 (56) 311861-G
8" 9.92 (252) 8.66 (193) 8.74 (222) 6.54 (166) 2.28 (58) 311871-G

Product Related Documents

Download this page as a pdf
Valves & Accessories » Butterfly Valves

GLR300G Grooved Butterfly Valves

GLR300G Grooved Butterfly Valves, Grooved End, Sizes: 2 ½", 65mm, 3", 4", 6",150mm, 8"

Specifications

Bronze butterfly Valves
  • Working Pressure: 300 PSI (21.4 Bars)
  • Max. Test Pressure: 600 PSI (42.8 Bars)
  • Max. Working Temp: 250°F (120°C)

Factory installed UL Listed Double Tamper Switch For Indoor and Outdoor Use.

Materials of Primary Components
Body ASTM A-536 Nylon-11 Coated
Disc ASTM A-536 EPDM
Encapsulated
Upper and Lower Stems AISI 420-SS
Worm Gear Shaft AISI 410-SS
Housing ASTM A-536
Hand Wheel ASTM A-536
Flag Indicator ASTM A-536
Sheer Pin ASTM A-510
Segment Gear ASTM B-148 or B-584
Housing Gasket EPDM Grade "E"
O-Rings (All) EPDM Grade "E"
 

Approvals

Size Approvals
cULus FM NYC - DOB MEA
Approved 155-06-E
2 ½"
65MM -
3"
4"
6"
150MM -
8" -

 

Cross Sections

larger image

Click image above for a detailed view of this product.

Dimension            Unit: in(mm)
Size A B C D E P/N
2 ½" 5.31 (135) 5.04 (128) 4.13 (105) 3.30 (85) 3.80 (96.4) 311785-G
65MM (76MM PIPE O.D.) 5.31 (135) 5.04 (128) 4.13 (105) 3.30 (85) 3.80 (96.4) 311785-GD
3" 5.59 (142) 5.04 (128) 4.41 (112) 3.60 (92) 3.80 (96.4) 311790-G
4" 6.89 (175) 5.04 (128) 5.71 (145) 4.30 (108) 4.54 (115.4) 311795-G
6" 8.23 (209) 8.66 (220) 7.05 (179) 5.71 (145) 5.21 (132.4) 311805-G
150MM (165MM PIPE O.D.) 8.23 (209) 8.66 (220) 7.05 (179) 5.71 (145) 5.21 (132.4) 311805-GD
8" 9.21 (234) 8.66 (220) 8.03 (204) 6.70 (170) 5.80 (147.4) 311815-G

Product Related Documents

Download this page as a pdf
Valves & Accessories » Butterfly Valves

GL175G Bronze Butterfly Valves Grooved

GL175G Bronze Butterfly Valves Grooved End, Sizes: 2" and 2½"

Specifications

Bronze butterfly Valves
  • Working Pressure: 175 PSI (12.5 Bars)
  • Max. Test Pressure: 350 PSI (25.0 Bars)
  • Max. Working Temp: 250°F (120°C)

Factory installed UL Listed Double Tamper Switch For Indoor and Outdoor Use.

Materials of Primary Components
Body ASTM B-505
Disc ASTM B-584 EPDM
Encapsulated
Upper Stem ASTM A-564 Type XM 12
Lower Stem ASTM A-564 Type XM 12
Gear Housing, Cover ASTM A-619
Hand Wheel ASTM A-619
Flag Indicator ASTM B-16
York Mechanism ASTM A-283
Stem Bushing ASTM B-16
Conduit Connector ASTM A-307
O-Rings (All) EPDM Grade "E"
Cover Gasket NBR

Approvals

  • NYC - DOB MEA Approved 155-06-E
  • UL, ULC Listed
  • FM Approved

Cross Sections

larger image

Click image above for a detailed view of this product.

Dimension            Unit: in (mm)
Size A B C P/N
2 " 1.96(49) 4.56 (114) 3.62 (90.5)
311765-G
2 ½" 2.18 (54.5) 4.56 (114) 3.82 (95.5)
311775-G

Product Related Documents

Download this page as a pdf
Valves & Accessories » Butterfly Valves

GL175T Bronze Butterfly Valves Threaded End

GL175T Bronze Butterfly Valves Threaded End, Sizes: 1", 1 ¼", 1 ½", 2" and 2½"

Specifications

Bronze butterfly Valves
  • Working Pressure: 175 PSI (12.5 Bars)
  • Max. Test Pressure: 350 PSI (25.0 Bars)
  • Max. Working Temp: 250°F (120°C)

Factory installed UL Listed Double Tamper Switch For Indoor and Outdoor Use.

Materials of Primary Components
Body ASTM B-505
Disc ASTM B-584 EPDM
Encapsulated
Upper Stem ASTM A-564 Type XM 12
Lower Stem ASTM A-564 Type XM 12
Gear Housing, Cover ASTM A-619
Hand Wheel ASTM A-619
Flag Indicator ASTM B-16
York Mechanism ASTM A-283
Stem Bushing ASTM B-16
Conduit Connector ASTM A-307
O-Rings (All) EPDM Grade "E"
Cover Gasket NBR

Approvals

  • NYC - DOB MEA Approved 155-06-E
  • UL, ULC Listed
  • FM Approved

Cross Section

larger image

Click image above for a detailed view of this product.

Dimension            Unit: in (mm)
SizeABCP/N
1" 2.16 (54) 2.08 (52) 1.48 (52) 311725-G
1¼" 2.68 (67) 2.24 (56) 1.64 (41) 311735-G
1½" 2.92 (73) 2.36 (59) 2.45 (61.3) 311745-G
2" 3.3 (82.4) 2.56 (64) 1.96 (49) 311755-G
2½" 4.16 (104) 2.78 (69.5) 2.18 (54.5) 311760-G

Product Related Documents

Download this page as a pdf
Valves & Accessories » RCV Check Valves

J-10 Swing Check Valve - Model “RCV” - 2” - 6”

Swing Check Valve Model RCV Standard & "Shotgun" Groove/Groove 2", 2 ½",65mm, 3", 4", 6" & 150mm Sizes

Description and Operation

Globe Model RCV Swing Check Valves feature a swing type clapper designed for use in fire sprinkler or other types of water piping systems that incorporate grooved connecting pipe ends. They are effectively used when it is necessary to permit water flow in one direction only, preventing flow in the reverse direction (non-return). Because the RCV incorpo- rates a spring-loaded clapper assembly, it may be installed in either the vertical or horizontal position. Most commonly, it is used with various configurations of fire department connections for fire sprinkler systems, by-pass connections, gravity pressure tank and, pump discharge in connections from public water supplies to automatic sprinkler systems, etc.

As an alternative to using an alarm check valve with a wet sprinkler system, an RCV Swing Check Valve may be used in a "Shotgun" arrangement whereby the valve is trimmed in a similar manner but utilizes an electric water flow switch and alarm bell instead of a water motor gong for fire notification.

The body of the Globe RCV Swing Check Valve is constructed of high tensile strength cast iron having considerable ductility to reduce damage in field handling. It meets the ASTM A126 Class B rating. The RCV clapper assembly is made of stainless steel and has an E.P.D.M. rubber facing. The RCV incorporates a special stainless steel spring assembly which allows its use in the downward flow direction. It effectively provides a leak tight seal against back pressures greater than one (1) psi.

Approvals

  • cULus Listed
  • FM Approved
  • NYC - DOB MEA. 305-05-E

Technical Data

  • Water Working Pressure Rating - 300 psi (20.7 Bars)
  • Factory tested hydrostatically to 600 psi (41.4 Bars)
  • Equivalent feet of pipe: 2" Valve = 7.2 feet, 2 1/2" Valve = 7.2 feet, 3" Valve = 7.2 feet, 4" Valve - 9.9 feet, 6" Valve = 16.1 feet
Size A C E F G H I J K L WEIGHT
(lbs.)
no trim
2" 1" 4" 3½" 4½" 6½" ¼" 1½" 2 ¼" 2½" 4¾" 4.5
2½" 1¼" 4½" 4" 5" 7 ¼" 1½" 2 ½" 5½" 8
65MM 1¼" 4½" 4" 5" 7 ¼" 1½" 2 ½" 5½" 8
3" 1¼" 5 4½" 6" 7¾" ¼" 2" 3" 12
4" 2" 6¼" 4" 6½" 8½" ¼" 2½" 3 ½" 4¼" 7½" 17.5
6" 2" 8" 5" 8" 10½" ¼" 3¼" 4 ¼" 5½" 10" 40.5
150MM 2" 8" 5" 8" 10½" ¼" 3¼" 4 ¼" 5½" 10" 40.5

Cross Section

Click image above for a detailed view of this product

ItemDescriptionMat'l2"P/N2½"P/N3"P/N4"P/N6"P/N
65MM 150MM
1 Hinge Pin Stainless Steel 321521 321528 321535 321541 321549
2 Torsion Spring
Stainless Steel 321523 321531 321531 321545 321554
3 Machined Body Cast Iron 321501 321503 321505 321507 321509
(DIN) (321503-D) (321509-D)
4 1/2" NPT Plug
Cast Iron 311003 311003 311003 311003 311003
5 Seat Ring
Brass 321516 321530 321537 321543 321551
6 Locknut
Stainless Steel 321556 321556 321556 321556 321556
7 Nameplate
Aluminum 321558 321558 321558 321558 321558
8 Clapper
Stainless Steel 321515 321527 321534 321540 321548
9 Clapper Facing Disc
EPDM 321516 321529 321536 321542 321550
10 Sealing Washer
Hard Fiber 321518 321518 321518 321518 321518
11 Disc Retainer
Stainless Steel 321517 321517 321517 321544 321544
12 Hex Head Bolt Stainless Steel 321519 321519 321555 321555 321559

"Shotgun" Trim Arrangement

SizeABC
2" 10" 8¾" 2¼"
2½" 11" 9¼" 2¼"
65MM 11" 9¼" 2¼"
3" 12" 9½" 2½"
4" 13½" 10" 3¼"
6" 14¼" 10¾" 4"
150MM 14¼" 10¾" 4"

Click image above for a detailed view of this product

ItemDescription2"(DIN 50)2½" 66mm
(76mm groove)
3"(DIN 80)4"(DIN 100)6" 150mm
(165mm groove)
Qty.
1 RCV
321526 321533 321533-D 321539 321547 321557 321557-D 1
2 Angle Valve
311614 (1") 311615 (1¼") 311615 (1¼") 311615 (1¼") 311617 (2") 311617 (2") 311617 (2") 1
3 Close Nipple
310500 (1") 310600 (1¼") 310600 (1¼") 310600 (1¼") 310800 (2") 310800 (2") 310800 (2") 1
4 1/4" Water Gauge
300119 300119 300119 300119 300119 300119 300119 2
5 1/4" 3 Way Valve
311683 311683 311683 311683 311683 311683 311683 2
6 1/4" Plug
311001 311001 311001 311001 311001 311001 311001 2
7 1/4" Nipple
311101 (1½") 311102 (2") 311102 (2") 310102 (2") 310103 (2½") 310103 (2½") 310103 (2½") 1
8 1/4" x 5 1/2" Nipple 310109 310109 310109 310109 310109 310109 310109 1

Ordering Information

When ordering, please specify the following.

  • Quantity
  • Model Number
  • Standard or Shotgun Style

Download this page as a pdf
Sprinklers » Nozzles & Window Sprinklers

I-1 Foam Nozzle - Model J

Foam Nozzle Model J Open Style

Description and Operation

FOAM NOZZLE MODEL JN

Globe's Model JN Foam Nozzles are most typically used with various foam compounds such as A.F.F.F., Fluoroprotein, Protein and Alcohol type foam liquids for the extinguishment and/or control of hydrocarbon based, polar solvents, and other flammable liquid fires.

Globe's Model JN Foam Nozzles are available in both 3/8" and 1/2" nominal orifice sizes and have a 1/2" NPT male thread. Globe's Foam Nozzle is available in the open style for use with deluge systems. The activation of the deluge valve causes the discharge of foam solution onto the floor in a parabolic shaped discharge pattern.

Technical Data

  • See reverse side for Specifications
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Screen mesh - stainless steel
  • Mounting plate - stainless steel
  • Retaining Ring - stainless steel
  • Weight 29 lbs. (131.5 grams)

Approvals

  • cULus Listed

Specifications

Orifice Size'K' FactorThread SizeLength x WidthFinishes
3/8" (10 mm) 2.8 (39 metric) 1/2" NPT


2 1/2" (63.5mm)
X
3 1/4" (82.6mm)

Factory Bronze*
1/2" (15 mm) 5.6 (80 metric) 1/2" NPT
Note:
  • Metric conversions are approximate.
  • Minimum recommended nozzle pressure is 15 P.S.I.(1.03 Bars)
  • *Finishes available upon special request.

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Quantity - Wrenches - P/N 312366

Download this page as a pdf
Sprinklers » Nozzles & Window Sprinklers

I-5 Window Sprinkler - Model “WS”

Window Sprinklers Model WS

Description and Operation

FOAM NOZZLE MODEL JN

Globe's Model WS Window Sprinklers are specially designed open style nozzles that provide a 180° relatively flat fan-shaped spray pattern. They are generally used to provide a water curtain over a glass window or other opening to prevent fire / heat penetration. They are also used to provide fire exposure protection from one closely located building to another and are also frequently used to protect steel beams and columns to help preserve structural integrity.

The water flow to Globe's Model Window Sprinkler is controlled either by a manually operated control valve or by means of an automatically operated deluge system.

Globe's Model WS Window Sprinklers may be installed in various positions depending on the hazard being protected. The Window Sprinkler installation diagram shown on this page represents a typical installation for the protection of glass windows. However, N.F.P.A. 13 should be consulted for the proper installation and spacing of the Globe Model WS Window Sprinklers.

Technical Data

  • Body - brass
  • Finish - brass and chrome; other finishes available upon request
  • Weights:
    1" Hex .25 lbs. (113.40 grams)
    1 1/4" Hex .30 lbs. (136.08 grams)

Approvals

  • cULus Listed

Specifications

Orifice SizeThread Size'K' FactorHeight
U.S.MetricU.S.MetricU.S.MetricU.S.Metric
1/4" 6.35 mm 1/2" 15 mm 1.4 20 mm 1 3/4" 44.45 mm
5/16" 7.94 mm 1/2" 15 mm 2.0 29 mm 1 3/4" 44.45 mm
3/8" 9.52 mm 1/2" 15 mm 2.8 40 mm 1 3/4" 44.45 mm
7/16" 11.11 mm 1/2" 15 mm 4.2 59 mm 1 3/4" 44.45 mm
1/2" 12.70 mm 1/2" 15 mm 5.6 80 mm 2 1/16" 52.39 mm
17/32" 13.49 mm 3/4" 20 mm 8.1 116 mm 2 1/16" 52.39 mm
5/8" 15.88 mm 3/4" 20 mm 11.4 163 mm 2 1/16" 52.39 mm

Cross Sections

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Finish
  • Orifice
  • Thread Size

Download this page as a pdf
Valves & Accessories » Dry Pipe System

G-2 Air Maintenance Device - Model “H-2” & “H-3”

Air Maintenance Device Model H-2, Model H-3

Description and Operation

Air Maintenance Device

Globe's Model H-2 and H-3 Air Pressure Maintenance Devices are automatic, field-adjustable devices that control the on-off cycling of an air compressor. They are used to control the supervisory air pressure in a dry pipe sprinkler system, preaction system, or dry pilot line system of a dry pilot sprinkler actuated deluge or preaction valve. The H-2 and H-3 are utilized in applications where it is desirable or necessary to use a small, non-tank mounted compressor that is to be dedicated to the system to be pressurized. The H-2 and H-3 monitor system pressure and automatically cycle the air compressor on and off to maintain system pressure within the preset limits.

The Model H-2 should be specified when the primary air compressor has an unloader as an integral part. After the initial system air pressure has been established, the 1/2" Globe valve is closed. As pressure on the system side of the 1/4" check valve drops, the air pressure switch contacts close, causing the compressor to start. A restricted orifice limits the rate at which air is replaced. When the system air pressure has been re-established, the switch contacts open, stopping the compressor.

Globe's Model H-3 Air Maintenance Device is similar in operation to the Model H-2. The Model H- 3, however, incorporates an unloader valve. This model is selected when the primary air compressor is not equipped with an unloader device. After the compressor has re-established the required air pressure on the system side of the check valve, the air pressure switch contacts open, stopping the compressor and operating a release valve. The release valve vents the compressor head to exhaust the air trapped between the compressor head and the bypass check valve. On the next automatic operating cycle, the compressor will start against atmospheric pressure, thus preventing excessive starting loads.

Approvals

  • UL Listed
  • FM Approved
  • NYC-DOB MEA 335-91-M

Technical Data

  • Physical Dimensions
    H-2 - 13 1/2" X 7" (343 mm X 178 mm)
    H-3 - 13 1/8" X 7 7/8" (334 mm X 200 mm)

Specifications

 U.S.Metric
Minimium Close Pressure 14 PSI 0.98 kg/cm2
Maximum Open Pressure 60 PSI 4.22kg/cm2
Differential Pressure 6-16 PSI 42 - 1.12 kg/cm2
Cut In 30 PSI 2.11 kg/cm2
Cut Out (Adjustable) 40 PSI 2.81 kg/cm2
2 HP3 HP5 HP3 HP5 HP2 HP
120V
single
phase
240V
single
phase
600V
single
phase
120V
3
phase
240 - 600V
3
phase
115 - 230V
DC
Note: Metric Conversions are Approximate.

Cross Sections

Click image above for a detailed view of this product

ItemDescriptionMat'lP/N ItemDescriptionMat'lP/N
1 Name Plate Aluminum 320596   9 ¼ Check Valve Aluminum 320589
2 ½ x 3 Nipple Steel 310304   10 ¼ X 1 ½ Nipple Steel 310101
3 ¼ Needle Valve
Brass 320586   11 Pressure Sw itch Purchase 320597
4 1/4 Union Steel 311401   12 3/8 X Close Nipple Steel 55122
5 ¼ Close Nipple Steel 310100   13 ½ x ½ x 3/8 Tee Steel 311309
6 ¼ Black Elbow
Steel 311201   14 ½ x 2 Nipple Steel 310302
7 ¼ Strainer Brass 320587   15 ½ Globe Valve Brass 311601
8 Metering Orifice Brass 320588   16 ½ X ½ X ¼ Tee Steel 311314

Click image above for a detailed view of this product

ItemDescriptionMat'lP/N ItemDescriptionMat'lP/N
1 Name Plate Aluminum 320601   10 ¼ X 1 ½ Nipple Steel 310101
2 ½ Globe Valve Brass 311601   11 ¼ Strainer Brass 320587
3 ½ Close Nipple Steel 310300   12 Metering Orifice Brass 320588
4 ½ x ½ x ¼ Tee Steel 311314   13 ¼ Check Valve Aluminum 320589
5 ½ x 2½  Nipple
Steel 310303   14 ¼ X ¼ X 3/8 Tee Steel 311309
6 ¼ Needle Valve Brass 320586   15 3/8 X Close Nipple Steel 55122
7 ¼ Union Steel 311401   16 Pressure Sw itch Purchase 320602
8 ¼ Close Nipple Steel 310100   17 Connector Tubing - 19" Copper 320604
9 ¼ Black Elbow Steel 311201   18 Tube Fitting Brass 320603

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number

Download this page as a pdf
Valves & Accessories » Dry Pipe System

G-1 Air Maintenance Device - Model H1

Air Maintenance Device - Model H1

Description and Operation

Globe's Model H-1 Air Pressure Maintenance Device is an automatic, field-adjustable device of the pressure reducing type. It is used to control the supervisory air pressure in a dry pipe sprinkler system, preaction system, or dry pilot line system of a dry pilot sprinkler actuated deluge or preaction valve. The H-1 is utilized in applications where there is a compressed air (or nitrogen) source which is at a higher pressure than the desired system pressure. Pressure sources include plant air supplies having their own automatic compressor controls, or nitrogen supplies having single-stage cylinder mounted pressure regulators.

The 1/2" globe valve is opened to admit air speedily to the dry pipe system. It is closed once the desired system air pressure has been established. As pressure drops on the system side of the 1/4" check valve, the regulator and metering orifice operate automatically to replace small losses of air which periodically occur in the system due to temperature or other system variations. The regulator and metering orifice limit the volume of air introduced to assure that the rate of air replacment is less than that from a discharging sprinkler so that system activation may take place.

Approvals

  • UL Listed
  • FM Approved
  • NYC-DOB MEA 335-91-M

Technical Data

  • Physical Dimensions
    9 11/16" x 7 3/4"
    (246 mm X 197 mm)

Specifications

 U.S.Metric
Pressure Range Output15-50 PSI1.05-3.51 kg/cm2
Pressure Differential 2 1/2 PSI 0.176 kg/cm2
Connections
From Air Supply 1/2" FEMALE NPT
To System 1/2" FEMALE NPT
Note: Metric Conversions are Approximate.

Cross Sections

ItemDescriptionMat'lP/N ItemDescriptionMat'lP/N
1 Name Plate Aluminum 320592   8 1/4 Black Elbow Steel 311201
2 1/2 Globe Valve Brass 311601   9 1/4 Strainer Brass 320587
3 1/2 X 3 1/2 Nipple Steel 310305   10 Metering Orifice Brass 320588
4 1/2 X 1/2 X 1/4 Tee Steel 311314   11 Air Regulator Aluminum 320590
5 1/4 Needle Valve Brass 320586   12 1/4 Check Valve Aluminum 320589
6 1/4 Union Steel 311401   14 1/4 X 2 Nipple Steel 310102
7 1/4 Close Nipple Steel 310100          

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number

Download this page as a pdf
Valves & Accessories » Dry Pipe System

F-1 Accelerator & Anti-Flooding Device - Model “C”

Accelerator and Anti-Flooding Device Model C

Description and Operation

Globe's Model C Accelerator is a precision made device used to reduce the time lag normally associated with the opening of a Dry Pipe Valve after one or more system sprinklers have operated. In essence, the Model C Accelerator "accelerates" the opening of the Dry Pipe Valve resulting in faster water discharge from the opened sprinkler(s).

The Model C Accelerator basically monitors the air pressure in a Dry Pipe System. If a rapid loss of system air pressure occurs, as would with the opening of one or more sprinklers, the accelerator senses this loss and immediately sends pressurized air to the intermediate chamber of the Dry Pipe Valve upsetting the pressure differential and causing it to operate instantly.

Globe incorporates the use of its Model C Anti-Flooding Device to help ensure the proper operation of the Model C Accelerator by preventing most water-borne foreign objects from entering the Accelerator. Such objects could cause clogging of the Accelerator and hinder its proper operation. Because of its importance, the Model C Anti-Flooding Device is always included with orders for the Model C Accelerator and should always be properly installed. Accelerators are precision made devices, however, and must be kept clean of foreign matter. A thorough cleaning after use is recommended.

After the Accelerator has operated, the pressurized air in the Accelerator Body and its associated piping is discharged to the Model C Anti-Flooding Device's lower inlet stopping any flow through the piping leading to the Accelerator. This occurs very quickly and always before water reaches the Anti-Flooding Device.

Approvals

  • cULus Listed
  • FM Approved
  • N.Y.C. - D.O.B MEA 353-91-M

Technical Data

  • Water Working Pressure Rating - 175 psi (1207 kPa)

Cross Sections

Accelerator

Click image above for a detailed view of this product

ItemDescriptionMat'lP/N ItemDescriptionMat'lP/N
1 Upper Chamber Bronze 300401   9 Restricted Orifice Pin Monel 300411
2 Lower Chamber and Valve Seat Assembly Bronze 300402   10 Valve Disc and Disc Retainer Assembly Neoprene/Brass 300412
3 Pressure Plate Brass 300405   11 Retaining Screw Bronze 300415
4 Diaphragm Plate Brass 300406   12 Spring Retainer Disc Brass 300416
5 Nut Bronze 300407   13 Gasket E.P.D.M. 300417
6 Gasket E.P.D.M. 300408   14 Spring Bronze 300418
*7 Clamping Ring Brass 300409   15 Plug Brass 300419
*8 Diaphragm Neoprene 300410          

*323489 Accelerator Clamping Ring Wrench (Item #7) for use when replacing the Diaphram Item #8.

Refer to Globe’s Dry Pipe Valve Installation and Maintenance Guide (Bulletin D.P.V.I.M.) for trim set-up.Anti-Flooding Device

Click image for a detailed view of this product

ItemDescriptionMat'lP/N
1 Top Brass 323334
2 Body Brass 323333
3 Diaphragm E.P.D.M 323335
4 Spring Stainless Steel 323336
5 Screw Steel 323337

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Size
  • Untrimmed or Factory Trimmed and Leak Tested Hydrostatically.

Product Related Documents

Download this page as a pdf
Valves & Accessories » Dry Pipe System

E-10 Dry Pipe Valve - Model “A” - 3”

Dry Pipe Valve Model A*, Flange/Flange 3" Size

Description and Operation

White Dry Adjustable Concealed Pendent

The Globe Model A Dry Pipe Valve is the vital control unit in dry pipe automatic sprinkler systems, where super- visory air under pressure is used to prevent freezing that would certainly occur with ordinary wet pipe systems. The Dry Pipe Valve is the connecting link between the source of water supply and the automatic sprinklers, and must react promptly when it receives a signal from the protected area that a fire condition has developed and water is therefore quickly needed. This signal is generated by the opening of one or more sprinklers which causes a quick drop in system supervisory air pressure resulting in a loss of the differential force ratio.

The single clapper assembly design in the Globe Model A Dry Pipe Valve, provides a differential force ratio of approximately 6:1 between system air pressure and water supply pressure. Once the valve has operated, a special latch holds the clapper open until manually reset by qualified personnel.

The body of the Dry Pipe Valve is constructed of high tensile strength cast iron having considerable ductility to reduce damage in field handling.

All interior operating parts are machined from highly corrosive-resistant copper alloys, each having high strength and good wear resistance.

Rubber parts are of selective materials which have good abrasive resistance and long life expectancy in terms of resiliency.

NOTE:  *Formerly known as Model D

Approvals

  • cULus Listed
  • FM Approved

Technical Data

  • Water Working Pressure Rating - 175 psi (12Bars)
  • Factory tested hydrostatically to 350 psi (24Bars)
PHYSICAL DATA
Size3"
Overall Length 14 1/2"
Center of Valve to Front 11"
Center of Valve to Back 9"
Center of Valve to Right 17"
Center of Valve to Left 6"
Weight of Value 106 lbs.

 

Water
Pressure
P.S.I
Air Pressure
Requirements
P.S.I
max min max
30 15 20
50 20 25
75 25 30
100 30 35
125 35 40
150 40 45
175 45 50

Cross Sections

Click image above for a detailed view of this product

ItemDescriptionMat'lP/N ItemDescriptionMat'lP/N
1 Cover Plate Cast Iron 318501   12 Machine Screw Bronze 318512
2 Cover Plate Gasket Rubber 318502*   13 Pin Air Seat Gasket Rubber 318513*
3 Cover Plate Stud Steel 318503   14 Water Seal Gasket Rubber 318514*
4 Nut Steel 318504   15 Machine Screw Brass 318515
5 Latch Cast Iron 318505   16 Clapper Hinge Pin Brass 318516
6 Clapper Arm Assembly ------- 318506   17 Cotter Pin Brass 318517
7 Clapper Arm Hinge Pin Monel 318507   18 Latch Pin Brass 318518
8 Hinge Pin Plug Brass 318508   19 Retaining Washer Brass 318526
9 Clapper Assembly ----- 318509   20 Seat Ring Bronze 318522
10 Clapper Bronze 318510   21 Air Seat Bronze 318523
11 Clapper Ring Bronze 318511          

* Available as a kit only - P/N 318519

Refer to Globe's Dry Pipe Valve Installation and Maintenance Guide (Bulletin D.P.V.I.M.) for trim set-up,
installation instructions, and maintenance.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Size
  • Factory Trimmed and Leak Tested Hydrostatically or Loose Trim for Customer Installation.

Product Related Documents

Download this page as a pdf
Valves & Accessories » Dry Pipe System

E-1 Dry Pipe Valve - Models “F-3” & “G-3” - 4” &  6”

Dry Pipe Valve Model F-3 Flange/Flange, Model G-3 Flange/Groove 4" & 6" Sizes

Description and Operation

White Dry Adjustable Concealed Pendent

The Globe Model F-3 and G-3 Dry Pipe Valves are the vital control unit in dry pipe automatic sprinkler systems, where supervisory air under pressure is used to prevent freezing that would certainly occur with ordinary wet pipe systems. The Dry Pipe Valve is the connecting link between the source of water supply and the automatic sprinklers, and must react promptly when it receives a signal from the protected area that a fire condition has developed and water is therefore quickly needed. This signal is generated by the opening of one or more sprinklers which causes a quick drop in system supervisory air pressure resulting in a loss of the differential ratio.

The single clapper assembly design in the Globe Model F-3 and G-3 Dry Pipe Valves, provides several areas exposed to working pressures which, in combination, create a differential force ratio between system air pressure and water supply pressure. A single-latching lever is provided as a means of holding the clapper in "set" position. Once the valve has operated, a special latch holds the clapper open until manually reset by experienced personnel.

The body of the Dry Pipe Valve is constructed of high tensile strength cast iron having considerable ductility to reduce damage in field handling.

All interior operating parts are machined from highly corrosive-resistant copper alloys, each having high strength and good wear resistance.

Rubber parts are of selective materials which have good abrasive resistance and long life expectancy in terms of resiliency.

Approvals

  • cULus Listed
  • FM Approved
  • NYC - DOB MEA 324-91-M

Technical Data

  • Water Working Pressure Rating - 175 psi (1207 kPa)
  • Factory tested hydrostatically to 350 psi (2414 kPa)
PHYSICAL DATAModel Size
F-3G-3
4"6"4"6"
Overall Length 16" 16 ½" 16" 16 ½"
Center of Valve to Back 11" 12" 11" 12"
Center of Valve to Right 12" 12" 12" 12"
Center of Valve to Left 10" 11" 10" 11"
Weight of Valve
Complete with
all Trimmings
161 lbs
179 lbs.
231 lbs.
249 lbs.
151 lbs
169 lbs.
221 lbs.
239 lbs.
Minimum Inside Dimensions
of Enclosing Valve House
45" x 52" 45" x 52" 45" x 52" 45" x 52"
Friction Loss in Equivalent
Feet
19' - 6" 31' - 0" 19' - 6" 31' - 0"

 

Water
Pressure
P.S.I
Air Pressure
Requirements
P.S.I
max min max
30 15 20
50 20 25
75 25 30
100 30 35
125 35 40
150 40 45
175 45 50

Cross Sections

Click image above for a detailed view of this product

ItemDescriptionMat'l4" P/N6" P/N ItemDescriptionMat'l4" P/N6" P/N
1 Bellofram EPDM 319794 319844   20 Side Cover Plate Cast Iron 319767 319814
2 Seat Ring Bronze 300014 300213   21 Pin Bronze 300011 300210
3 Clapper and Ring Assembly Bronze 319779 319821   22 Packing Nut Bronze 300025 300025
4 Lever Bronze 319757 319807   23 Cover Bolt Steel 319768 319815
5 Rubber Seat Ring EPDM 319791 319841   24 Cap Screw (6 req'd) Bronze 319760 319760
6 Compression Plate Bronze 319752 319802   25 Rubber Gasket Rubber 300030 300030
7 Retaining Ring Bronze 319792 319842   26 Pin Brass 300031 300031
8 Clapper Latch Bronze 300015 300214   27 Bronze Washer Bronze 300032 300032
9 Locking Stud Bronze 300016 300215   28 Packing Gland Ring Bronze 300035 300035
10 Body - F-3 Cast Iron 319765 319813   29 Lock Washer Bronze 319761 319761
  Body - G-3 Cast Iron 319704 319812   30 Cap Screw Bronze 319762 319762
11 Hinge Pin Bronze 300018 300217   31 Shield Elastomer 319758 319808
12 Bushing Bronze 300019 300218   32 Memory Washer Brass 319763 319811
13 Pin Bronze 319798 319845   33 Cotter Pin Brass 300211 300211
14 Latch Screw Brass 300020 300020   34 Nut Brass 319756 319806
15 Plug Bronze 300021 300021   35 Packing PTFE 300036 300036
16 Atmospheric Discharge Tube Brass 319766 300022   36 1" Close Nipple Galvanized 310303-G 310303-G
17 Retaining Ring Screw (6 req'd) Bronze 319778 319778   37 1" Elbow Steel 311205 311205
18 Cover Plate Gasket Rubber 300023 300219   N/S Cover Release Screw Stainless 300012 300012
19 Clamping Ring Bronze 319793 319843            

Refer to Globe's Dry Pipe Valve Installation and Maintenance Guide (Bulletin D.P.V.I.M.) for trim set-up,
installation instructions, and maintenance.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Size
  • Factory Trimmed and Leak Tested Hydrostatically or Loose Trim for Customer Installation.

Product Related Documents

Download this page as a pdf
Valves & Accessories » Wet Alarm System

D-1 Retarding Chamber Model H

Retarding Chamber Model H

Description and Operation

White Dry Adjustable Concealed Pendent

The Globe Model H Retarding Chamber is an accessory which is used with variable pressure wet sprinkler systems where water motor alarms and / or pressure switches are used in conjunction with Globe's Alarm Check Valves. It serves primarily as a hydraulic time delay to prevent most false alarms associated with fluctuating water supply pressures. In situations where excessive water pressure surges occur, the Model H Retarding Chamber is needed to collect excess water from the Alarm Check Valve and feed water back into the main drain, before activating the alarm. An additional retarding chamber could be needed if pressure surges exceed the capacity of one retarding chamber.

Water enters the retarding chamber through the 1/2" NPT Inlet and automatically flows through a restricted orifice and to drain; when the drain capacity is exceeded, as when the alarm check valve clapper remains open or when the system is being tested, the retarding chamber capacity is reached, and water then flows through the Outlet to the water motor alarm and / or electric alarm switch.

The body of the Retarding Chamber has considerable ductility to reduce damage in field handling.

All interior operating parts are machined from highly corrosive-resistant alloys, each having high strength and good wear resistance.

Approvals

  • cULus Listed
  • FM Approved
  • LPCB Approved

Technical Data

  • Water Working Pressure Rating - 175 psi (12 bars)
  • Factory tested hydrostatically to 350 psi (24 bars)
  • Capacity - 1 Gallon (3.785 liters)
  • Body - High Tensile Cast Iron

Cross Sections


Click image for a detailed view of this product

ItemDescriptionMat'lP/N
1 Outlet Bushing Cast Iron 323354
2 Machined Body Cast Iron 323352
3 Hex Head Machine Screw Brass 323357
4 Cup Brass 323356
5 Strainer Screen Brass 323355
6 Drain Bushing Brass 323353
Refer to Globe’s Alarm Check Valve Installation and Maintenance Guide (Bulletin A.C.V.I.M.) for trim set-up, installation instructions, and maintenance.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number

Download this page as a pdf
Valves & Accessories » Wet Alarm System

C-2 Alarm Check Valve - Model “H” Series 8”

Alarm Check Valve 8" Model H-1 Flange/Flange, 8" Model H-3 Flange/Groove

Description and Operation

White Dry Adjustable Concealed Pendent

The Globe Model H-1 and H-3 8" Alarm Check Valves are used in wet pipe fire sprinkler systems. They primarily serve a dual purpose in that they prevent a reverse flow of water through their bodies (non-return) and also provide for the use of a hydraulic fire alarm which is not dependent upon an electrical power supply for its operation. Through the use of a hydraulic retard chamber a time delay is provided to eliminate potential false alarms caused by fluctuating water supply pressures. Where constant pressure water supplies are used the retard chamber (time delay) is not necessary. By incorporating the use of electrical pressure switches, other supplemental alarms, annunciators etc. may also be used.

Globe 8" Model H-1 and H-3 Alarm Check Valves may be installed in the vertical position and trim can be provided for both variable and constant water supply pressures.

The body of the Alarm Check Valve is constructed of high tensile strength cast iron having considerable ductility to reduce damage in field handling.

All interior operating parts are machined from highly corrosive-resistant alloys, each having high strength and good wear resistance.

Rubber parts are of selective materials which have good abrasive resistance and long life expectancy in terms of resiliency.

Technical Data

  • Water Working Pressure Rating - 175 psi (12 bars)
  • Factory tested hydrostatically to 350 psi (24 bars)
  • Equivalent feet of pipe: 8" Valve = 21 feet
Physical DataModel Size
H-1H-3
Overall Length 13 7/8" 15 1/8"
Weight of Valve
Complete with
Verticle Variable
Pressure
Trimmings
150 lbs. 130 lbs.
200 lbs. 180 lbs.

Approvals

  • cULus Listed
  • FM Approved

Cross Sections

Click image above for a detailed view of this product

ItemDescriptionMat'lP/N
1 Body - H-1 Cast Iron 323832
  Body H-3 Cast Iron 323851
2 Cover Cast Iron 323835
3 Cover Gasket Rubber 323833
4 Cover Bolt Steel 323839
5 Seat Ring Bronze 323837
6 Clapper Bronze 323841
7 Clapper Disc EPDM 323842
8 Disc Retainer Stainless 323843
9 Disc Retainer Bolt Stainless 323838
10 Hinge Pin Stainless 323845
11 Hinge Pin Bushing Bronze 323846
12 Name Plate Aluminum 323480
13 Drive Screw Stainless 323420
Refer to Globe's Alarm Check Valve Installation and Maintenance Guide (Bulletin A.C.V.I.M.) for trim set-up, installation instructions, and maintenance.

Product Related Documents

Download this page as a pdf
Valves & Accessories » Wet Alarm System

C-1 Alarm Check Valve - Model “H” Series: 3”, 4”, and 6”

Alarm Check Valve 3", 4" & 6" Model H-1 Flange/Flange, 3" & 4" Model H-2 Groove/Groove, 3", 4" & 6" Model H-3 Flange/Groove

Description and Operation

White Dry Adjustable Concealed Pendent

The Globe Model H-1, H-2 and H-3 Alarm Check Valves are used in wet pipe fire sprinkler systems. They primarily serve a dual purpose in that they prevent a reverse flow of water through their bodies (non-return) and also provide for the use of a hydraulic fire alarm which is not dependent upon an electrical power supply for its operation. Through the use of a hydraulic retard chamber a time delay is provided to eliminate potential false alarms caused by fluctuating water supply pressures. Where constant pressure water supplies are used, the retard chamber (time delay) is not necessary. By incorporating the use of electrical pressure switches, other supplemental alarms, annunciators etc. may also be used.

A unique feature found on the Globe 3", 4" and 6" Alarm Valves is the clapper being hinged to the handhole cover for extreme ease of removal for inspection and service.

Globe Model H-1, H-2 and H-3 Alarm Check Valves may be installed in both vertical and horizontal positions, and trim can be provided for both variable and constant water supply pressures in either of these positions.

The body of the Alarm Check Valve is constructed of high tensile strength cast iron having considerable ductility to reduce damage in field handling.

All interior operating parts are machined from highly corrosive-resistant alloys, each having high strength and good wear resistance.

Rubber parts are of selective materials which have good abrasive resistance and long life expectancy in terms of resiliency.

Technical Data

  • Water Working Pressure Rating - 175 psi (12 bars) (See below for more specific rating approvals.)
  • 4" Model "H-1" cULus Listed with D.I.N. Class 16 flanges has a pressure rating of 16 bars
  • 4" and 6" Model "H-1" LPCB Approved for a 16 bar pressure rating with DIN Class 16 flanges and for a 20 bar pressure rating with DIN Class 25 flanges
  • Factory tested hydrostatically at twice the rated working pressure
  • Equivalent feet of pipe: 3" Valve = 12.2 feet, 4" Valve = 9.7 feet, 6" Valve = 17 feet
PHYSICAL DATAModel / Size
H-1H-2H-3
3"4"6"3"4"3"4"6"
Overall Length 9" 9" 10" 10" 10" 91/4" 91/2" 11"
Weight of Vavle
Complete with
Verticle Variable
Pressure
Trimmings
34 lbs. 42 lbs. 69 lbs. 20 lbs. 22 lbs. 28 lbs. 37 lbs. 59 lbs.
81 lbs. 89 lbs. 114 lbs. 57 lbs. 69 lbs. 75 lbs. 84 lbs. 100 lbs.

Approvals

cULus Listed 
FM Approved
LPCB Approved – H1 & H3
NYC – DOB MEA 325-91-M

Cross Sections

Click image above for a detailed view of this product

ItemDescriptionMat'l3" P/N4" P/N6" P/N
1 Body - H-1 Cast Iron 323803 323502 323562
  Body H-2 Cast Iron 323827 323552 ------
  Body H-3 Cast Iron 323807 323542 323592
2 Cover Bolt Steel 323408 323509 323569
3 Seat Ring Bronze 323809 323504 323564
4 Cover Cast Iron 323805 323507 323567
5 Clapper Stainless 323814 323510 323570
6 Retaining Ring Stainless 323527 323517 323517
7 Hinge Pin Stainless 323818 323516 323516
8 Cover Gasket Vellumoid 323810 323508 323568
9 Clapper Facing Disc EPDM 323815 323511 323571
10 Disc Retainer Stainless 323816 323512 323572
11 Lock Nut Stainless 323514 323514 323514
12 Disc Retainer Bolt Stainless 323817 323513 323573
13 Sealing Washer Hard Fiber 323515 323515 323515
14 Hinge Pin Bushing Bronze 323819 323518 323518
15 Name Plate Aluminum 323480 323480 323480
16 Drive Screw Stainless 323520 323520 323520
17 Torsion Spring Stainless 323528 323528 323565
18 Spring Bushing Brass ------ ------ 323579
Refer to Globe’s Alarm Check Valve Installation and Maintenance Guide  (Bulletin A.C.V.I.M.) for trim set-up, installation instructions, and maintenance.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Size
  • Factory Trimmed and Leak Tested Hydrostatically or Loose Trim for Customer Installation.

Product Related Documents

Download this page as a pdf
Valves & Accessories » Wet Alarm System

N-1 Water Motor Gong - Model WM & WM2

Water Motor Alarm Model WM Model WM-2

Description and Operation

White Dry Adjustable Concealed Pendent

Globe's Model WM and WM-2 Water Motor Alarms are hydraulically operated indoor and outdoor alarms for use with fire protection systems. They are lightweight yet durable, and can be used in conjunction with alarm check, dry pipe, deluge, and preaction valves to sound a local alarm. This water-powered system eliminates the need for an electrical alarm and will operate even if electrical power is lost.

Globe's Model WM Water Motor Alarm features a one- gong system which sounds an alarm outside the building. Globe's Model WM-2 Water Motor Alarm features a unique two-gong system which provides an audible fire alarm both inside and outside the building.

The Water Motor Alarms are suitable for mounting to any type of rigid wall and can accomodate a wall thickness up to 16" (406.4 mm). They are provided with a listed and approved strainer for use in the alarm line. The Gong, Gong Mount, and Water Motor Housing are fabricated from corrosion- resistant cast aluminum. The polymer drive bearings do not require lubrication.

The WM and WM-2 utilize a lightweight, impeller design which can produce a very high decibel sound level. As water passes through the water motor, the impeller turns and the shaft rotates. The rotating shaft drives a striker assembly which rings the gong, sounding a continuous alarm as long as the water flow continues.

Approvals

  • cULus Listed
  • FM Approved
  • NYC-DOB MEA 326-91-M

Technical Data

  • Body - cast aluminum
  • Finish - red

Cross Sections

Click image above for a detailed view of this product

Item Description Mat'l WM P/N WM-2 P/N
1 Gong Shell Aluminum 325506 325506
2 Hex Head Cap Screw Zinc 325521 325521
3 Gong Mounting Bracket Aluminum 325504 325504
4 Motor Cover Aluminum 325509 ------
  Inside Gong Backing Plate Aluminum ------ 325532
5 Impeller Housing Aluminum 325502 325502
6 Impeller Delrin 325507 ------
  Impeller - Inside Gong Delrin ------ 325533
7 Striker Shaft Delrin 325508 325508
8 Drive Shaft Aluminum 325515 325515
9 Threaded Pipe Galvanized Pipe 325517 325517
10 Striker Arm
Mild Steel 325510 325510
11 Cap Screw Zinc Plated 325520 325520
12 Knocker Phenolic 325513 325513
13 Knocker Retaining Washer Stainless Steel 325516 325516
14 Knocker Retaining Rivet Stainless Steel 325514 325514
15 Bearing-Thompson Type 6 Nylon 325518 325518
16 3/8 Helical Spring Lock Washer Steel 325522 325522
17 Backing Plate Gasket Velumoid 325511 325511
18 Wall Plate Mild Steel 325528 325528
Refer to Globe's Water Motor Alarm Installation and Maintenance Guide (Bulletin WMA-I) for trim set-up, installation instructions, and maintenance.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number

Product Related Documents

Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-2 Standard Escutcheons

Globe Standard Escutcheons

Standard Escutcheons 1/2” NPT or 3/4” NPT
Universal for all sprinkler models

1 Pc. (1/4” x 3” Diameter)

Finish/Part No. 1/2” NPT:
  • Chrome: 325398
  • Chrome-RP: 325398-RP
  • Brass: 325399
  • White: 325400

1 Pc. (5/8” x 2 7/8” Diameter)

Finish/Part No. 1/2” NPT:
  • Chrome: 312086
  • Brass: 312088
  • White: 312090
Finish/Part No. 3/4” NPT:
  • Chrome: 312087
  • Brass: 312089
  • White: 312091

2 Pc. (max. 2 3/4” x 3 1/2” Diameter)

Finish/Part No. 1/2” NPT:
  • Chrome: 312075
  • Chrome-P: 312075-P
  • Brass: 312076
  • White: 312074
  • White-P: 312074-P
Finish/Part No. 3/4” NPT:
  • Chrome: 312077
  • Brass: 312078
  • White: 312079

Optional Skirts for 2 Pc. Extended Escutcheon Short Taper Skirt
(reduces deflector to ceiling distance by 3/4”)

Finish/Part No.
  • Chrome: 312040
  • Brass: 312041
  • White: 312042

Flush Skirt
(reduces deflector to ceiling distance by 1 1/4”)

Finish/Part No.
  • Chrome: 312044
  • Brass: 312045
  • White: 312046
*NOTE: Other Escutcheons Available Upon Request. Unless stated “-RP” (rust proof) or “-P” (plastic), all escutcheons are coated/plated for decorative purposes only, thus not recommended for corrosive atmospheres.

Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-10 Escutcheon Tool

Escutcheon Tool For Recessed Automatic Sprinklers

Description and Operation

Sprinklers

Globe's escutcheon installation tool for recessed style sprinklers is designed for the installation of Globe's Friction Type Recessed Escutcheon.

By varying the length of the PVC pipe used, the escutcheon may be installed from the floor without the use of scaffolding, ladder, etc., for most ceiling heights.

The Globe Escutcheon Installation Tool incorporates an internal spring to compensate for the amount of the sprinkler exposed below the ceiling.

Technical Data

  • PVC Plastic with stainless steel spring

Cross Sections





Download this page as a pdf
Sprinklers » Sprinkler Accessories

B-1 Sprinkler Headguard Without Water Shield

Sprinkler Headguard Model GL Series Automatic Sprinklers

Description and Operation

Sprinklers

The Globe Model GL Series sprinkler is designed for use where mechanical injury to the sprinkler might be expected. Typical areas of usage are in storage racks or under open grating.

The Globe headguard can be used with either the 1/2" or 17/32" orifice Model GL Series sprinklers.

Technical Data

  • Overall Length
    1/2" NPT sprinklers - 2 7/8"
    3/4" NPT sprinklers - 3"
    1/2" NPT & 3/4" NPT sprinklers - 3 1/4"
  • Materials
    Headguard - steel
  • Finishes
    Red Enamel painted
    Chrome plated

Approvals

FM Approved for use with the Globe GL Series 1/2" and 17/32" orifice upright sprinklers.


Download this page as a pdf
Sprinklers » Sprinkler Accessories » Dry Sprinklers » Dry Type Accessories

B-1 Sprinkler Headguard With Water Shield

Sprinkler Headguard with Water Shield for Model GL Series Automatic Sprinklers

Description and Operation

Sprinklers

The Globe Model GL upright sprinkler combined headguard and water shield is designed for use where mechanical injury to the sprinkler might be expected and where a water shield is needed to protect the sprinkler's thermosensitive element from the water spray discharge of higher elevation sprinklers which could operate sooner during a fire.

The Globe combined headguard and water shield can be used with either the 1/2" or 17/32" orifice Model GL upright sprinklers.

Typical areas of usage are in storage racks, under open grating or even outdoors as a protection from weather.

Technical Data

  • Overall Length
    1/2" NPT sprinklers - 2 7/8"
    3/4" NPT sprinklers - 3"
  • Materials
    Headguard - steel
    Water shield - steel
  • Finishes
    Red Enamel painted
    Chrome plated

Approvals

FM Approved for use with the Globe GL Series 1/2" and 17/32" orifice upright sprinklers.


Download this page as a pdf
Dry Sprinklers » Dry Type Sprinkler Vertical Sidewall

A-94 Dry Type Vertical Sidewall Sprinkler

GL Series Dry Type Vertical Sidewall Upright & Pendent

White Dry Adjustable Concealed Pendent

The Globe GL Series Dry Type Vertical Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe GL Series Dry Type Vertical Sidewall Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with glycerin solution, 5mm size
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLength*Finishes
5.6 (80 metric) 3/4" or 1" NPT Variable
to 48"
Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Wax Coated1
Wax Over Lead1
8.1 (116 metric) 1" NPT
Note:
  • Metric conversions are approximate.
  • *cULus listed for up to a 48" "A" dimension.
  • 1Finishes available on special order
  • Wax coating cULus listed up to 200°F.
  • 2C-U.L. listed corrosion resistant - polyester must be specified on order.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
*cULusNYC - DOB
MEA 101-92-E
Vertical
Sidewall
GL5687 5.6 1" NPT
GL5688 5.6 3/4" NPT
GL8187 8.1 1" NPT
Note:
  • *3/4" NPT x 5.6K orifice and 1" NPT x 8.1K orifice listed for ordinary hazard.
  • Pendent vertical sidewall cULus listed for 6' min. spacing.
  • Upright vertical sidewall cULus listed for 9' min. spacing.


Globe GL Series Dry Vertical sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

The GL Series Dry Sprinkler must not be installed in a short radius 90° elbow. When installing in other than an iron tee, the clearances between the end of the sprinkler and fitting should be checked.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

 

 

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used;
    "B" Dimension - Distance from face of fitting to the top of the deflector.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Upright

A-95 GL Series Dry Type Upright Sprinkler

GL Series Dry Type Upright

Description and Operation

The Globe GL Series Dry Type Upright Sprinkler is designed for use in special applications such as freezing environments. As an example, they may be efficiently used when connected to a wet type sprinkler system and extended into an unheated attic space.

The Globe GL Series Dry Type Upright Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in the approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C), 155°F (68°C)
    175°F (79°C), 200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring assembly - teflon coated nickel alloy and brass
  • Bulb - glass with glycerin solution, 5mm size
  • Orifice insert -brass
  • 3/4 NPT or 1" NPT
  • Stabilizer bar - bronze
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT cULus Variable
to 48"
Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester
Black Polyester
Lead Coated1
Wax Coated1
Wax over Lead1
8.1 (116 metric) 1" NPT FM Variable to
36"
Note:
  • Metric conversions are approximate.
  • cULus listed corrosions resistent; Polyester must be specified on order.
  • 1Finishes available on special order.
  • - Wax Coating cULus listed up to 200°F.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULus*FMNYC - DOB
MEA 101-92-E
Upright GL5683 5.6 1" NPT
GL5684 5.6 3/4" NPT
GL8183 8.1 1" NPT
Note:
  • Listed for all hazards.
  • Dry Upright Sprinklers require a minimum operating pressure of 12 psi.
  • * Dry Upright - FM Approved 155°F, 200°F, and 286°F.

Cross Section

Click image above for a detailed view of this product

Important Installation Data

Globe GL Series Dry Upright sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the end fitting. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

The GL Series Dry Sprinkler must not be installed in a short radius 90° elbow. When installing in other than an iron tee, the clearances between the end of the sprinkler and fitting should be checked.

For further important installation data, please refer to our Dry Sprinkler Caution Sheet.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • "B" Dimension - Distance from face of fitting to the top of the deflector

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Horizontal Sidewall

A-93 Dry Type Horizontal Sidewall Sprinkler

GL Series Dry Type Horizontal Sidewall Recessed Horizontal Sidewall

Description and Operation

The Globe GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples.

The Globe GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with glycerin solution, 5mm
  • Orifice insert - brass
    3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT

cULus Variable
to 48"

FM Variable to
36"

Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester
Black Polyester
Lead Coated1
Wax Coated1
Wax Over Lead1
8.1 (116 metric) 1" NPT
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order
    - Wax Coating cULus listed up to 200°F
  • cULus listed corrosion resistant: Polyester must be specified on order.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULus*FMNYC - DOB
MEA 101-92-E
Horizontal
Sidewall
GL5685a 5.6 1" NPT
GL5686a 5.6 3/4" NPT
GL8185b 8.1 1" NPT
Recessed
Horizontal
Sidewall
GL5685a 5.6 1" NPT
GL5686a 5.6 3/4" NPT
GL8185b 8.1 1" NPT
Note:
  • aListed for light hazard only with deflector from 4" to 12" below the ceiling.
  • bListed for light and ordinary harzard with deflector from 4" to 12" below the ceiling.
  • * Dry Horizontal Sidewall - FM Approved 155°F, 200°F, and 286°F only.
  • * Dry Recessed Horizontal Sidewall - FM Approved 155°F and 200°F only.

Cross Sections



Important Installation Data

Globe GL Series Dry Horizontal Sidewall sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • Quantity - Recessed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
  • Escutcheon desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Concealed Pendent

A-92 Dry Type Adjustable (Dome) Concealed Pendent Sprinkler

GL Series Dry Type Adjustable Concealed Pendent

Description and Operation

White Dry Adjustable Concealed PendentThe Globe GL Series Dry Type Adjustable Concealed Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. It offers the ultimate in low profile, aesthetically pleasing appearance. The sprinkler is available with 1/2" of adjustment and a deeper profile ceiling plate, 3 5/16" diameter, color finished to match the specifier's exact requirements. Globe's Dry Adjustable Concealed Sprinkler utilizes a frangible 5mm glass bulb type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move; allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern.

A special spring is attached to the pendent deflector that serves to provide a constant tension against the ceiling plate. This feature virtually ensures freedom from environmental vibration problems.

The heart of Globe's GL Series sprinkler proven actuation assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass cdischarge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring Assembly - teflon coated nickel alloy and brass
  • Bulb - glass with glycerin solution, 5mm size
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Stabilizer bar - bronze
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLength*Finishes
5.6 (80 metric) 3/4" or 1" NPT Variable to
48"
Bright Chrome
White Polyester
1Satin Chrome
1Bright Brass
1Other Painted Finishes
8.1 (116 metric) 1" NPT
Note:
  • Metric conversions are approximate.
  • *cULus listed for up to a 48" "A" dimension.
  • 1Finishes available on special order. Painted plates other than white require customer to furnish paint. Contact Globe for paint specification.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F (57°C)
w/plate
135°F (57°C)
155°F (68°C)
w/plate
135°F (68°C)
155°F (68°C)
w/plate
155°F (68°C)
175°F (79°C)
w/plate
155°F (68°C)
200°F (93°C)
w/plate
155°F (68°C)
*cULus
Concealed
Pendent
GL5677 5.6 1" NPT
GL5678 5.6 3/4" NPT
GL8177 8.1 1" NPT
Note: *Listed for all hazards

Cross Section


Click image above for a detailed view of this product

Important Installation Data

Globe GL Series Dry Concealed sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327119
  • "A" Dimension - Distance from face of fitting to the
      finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Concealed Pendent

A-91 Dry Type Concealed Pendent Sprinkler

GL Series Dry Type Concealed Pendent

Description and Operation

White Dry Concealed Pendent

The Globe GL Series Dry Type Concealed Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. It offers the ultimate in low profile, aesthetically pleasing appearance. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Dry Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Dry Concealed Sprinkler utilizes its frangible 5mm glass bulb type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern.

A special spring is attached to the pendent deflector that serves to provide a constant tension against the ceiling plate. This feature virtually ensures freedom from environmental vibration problems.

The heart of Globe's GL Series sprinkler proven actuation assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with glycerin solution, 5mm size
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT

cULus Variable to
48"

FM Variable to
36"

Bright Chrome
White Polyester
1Satin Chrome
1Bright Brass
1Other Painted Finishes
8.1 (116 metric) 1" NPT
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • Painted plates other than white require customer to furnish paint. Contact Globe for paint specification.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F (57°C)
w/plate
135°F (57°C)
155°F (68°C)
w/plate
135°F (68°C)
155°F (68°C)
w/plate
155°F (68°C)
175°F (79°C)
w/plate
155°F (68°C)
200°F (93°C)
w/plate
155°F (68°C)
cULus* FM
Concealed
Pendent
GL5681 5.6 1" NPT
GL5682 5.6 3/4" NPT  
GL8181 8.1 1" NPT  
Note: Listed for all hazards
* Concealed Pendent style - FM Approvals 135° F Cover & 155° F Sprinkler; 155° F Cover & 200° F Sprinkler

Cross Section

Click image above for a detailed view of this product

Installation Data

Globe GL Series Dry Concealed sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327119
    "A" Dimension - Distance from face of fitting to the
    finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Pendent

A-90 Dry Type Pendent Sprinkler

Model GL5679, GL8179 Dry Type Pendent Recessed Pendent

Description and Operation

The Globe GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe GL Series Dry Type Pendent Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT

cULus Variable
to 48"

Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester
Black Polyester
Lead Coated1
Wax Coated1
Wax over Lead1
8.1 (116 metric) 1" NPT FM Variable
to 36"
Note:
  • Metric conversions are approximate.
  • cULus listed corrosion resistant: Polyester must be specified on order.
  • 1Finishes available on special order.
    - Wax Coating cULus listed up to 200°F

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULus*FMNYC - DOB
MEA 101-92-E
Pendent GL5679 5.6 1" NPT
GL5680 5.6 ¾" NPT
GL8179 8.1 1" NPT
Recessed
Pendent
GL5679 5.6 1" NPT
GL5680 5.6 ¾" NPT
GL8179 8.1 1" NPT
Note:
  • Listed for all hazards
  • * Dry Recessed Pendent - FM Approved 155°F and 200°F only.
  • * Dry Pendent - FM Approved 155°F, 200°F, and 286° only.

Cross Section


Installation Data

Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • Quantity - Recessed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
  • Escutcheons desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Extra Large Orifice

A-82 ELO 231/13 Upright Sprinkler - GL1167

Model GL1167 Extra Large Orifice For Use in NFPA 13, 231, 231C, 231D, & 231F Systems

Description and Operation

The Globe Model GL1167 Extra Large Orifice Upright Sprinkler is intended for use in NFPA 13, 231, 231C, 231D and 231F Systems, when installed in accordance with the Standard Sprinkler Positioning and area / density flow calculation requirements as specified in each respective standard. When acceptable to the Authority having Jurisdiction the Model GL1167 Sprinkler may be used as a "special application" sprinkler when installed to protect single, double and multiple-row and portable rack storage of Class I - IV group A and B plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded with a maximum storage height of 20 feet, maximum ceiling height of 25 feet, 36 inches minimum deflector to top of storage clearance, design density of 0.60 gpm/sq. ft., and a design area of 2,000 sq. ft. for wet systems or 2,600 sq. ft. for dry systems.

The Model GL1167 Sprinkler is a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various area coverages. This sprinkler series is available in the upright style and several temperature ratings and finishes to meet varying design requirements.

The heart of Globe's Model GL1167 sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Minimum Operating Pressure - 10 psi (0.7 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is -67°F (-55°C).
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 155°F 68°C Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
11.5 (166 metric) 3/4" NPT 2 7/16" (6.2 cm) Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as UL listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULusNYC - DOB
MEA 101-92-E
Upright GL1167 11.5

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Extra Large Orifice

A-80 ELO 13 Pendent Sprinkler - GL1160

Model GL1160 Extra Large Orifice Automatic Sprinklers For Use in NFPA 13 Systems

Description and Operation

The Globe Model GL1160 Extra Large Orifice Sprinkler for use in NFPA 13 Systems is a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. The main use of this sprinkler is when minimal pressure is available and the use of smaller size orifice sprinklers would require the installation of a pump. This sprinkler series is available in various styles, temperature ratings and several finishes to meet many varying design requirements.

The heart of Globe's Model GL1160 sprinkler proven actuating assembly is a hermetically sealed frangible glass am- pule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -  155°F (68°C),
    175°F (79°C), 200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 155°F 68°C Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
11.5 (166 metric) 3/4" NPT 2 7/16" (6.2 cm) Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as UL listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULusNYC - DOB
MEA 101-92-E
Pendent GL1160 11.5

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Horizontal Sidewall

A-77 Extended Coverage Light Hazard Horizontal Sidewall Sprinkler - GL8128, GL8129 & GL8174

Extended Coverage Light Hazard Model GL8128, GL8129, GL8174 Horizontal Sidewall

Description and Operation

The Globe Models GL8128, GL8129 and GL8174 Extended Coverage Horizontal Sidewall Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various area coverages and should be installed in accordance with NFPA 13. This sprinkler series is available in various temperature ratings and several finishes to meet many varying design requirements.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C), 155°F (68°C),
    200°F (93°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 200°F 93°C Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 3" (7.6 cm) Factory Bronze
1Satin Chrome
Bright Chrome
White Polyester2
Black Polyester2
1Lead Coated
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as UL listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
135°F
57°C
155°F
68°C
200°F
93°C
†cULusNYC - DOB
MEA 101-92-E
Sidewall GL8128 8.1
GL8129
GL8174
U.L. Listing Design - Use Requirements For Light Hazards
*SIN
Model
StyleTEMPCeiling to
deflector distance
Width of
coverage
Length of
coverage
MIN. PRESSURE
P.S.I.
FLOW
G.P.M.
GL8128
GL8129
Standard
&
Recessed
135°F / 57°C
155°F / 68°C
**200°F / 93°C
4" TO 6"
6" TO 12"
16' 16' QR Models Shown on Page A-46
18'
20' 16.6 33
22' 20.8 37
***24' 26.8 42
GL8174 Standard
&
Recessed
135°F / 57°C 12" TO 18" 16' 16' 12.0 28
18' 14.6 31
20' 18.7 35
22' 20.8 37
Note:
*Minimum 6' sprinkler spacing.
**200°F Sprinkler not listed for 16' x 22' OR 16' x 24'.
*** 24' Coverages not listed for recessed installations.

Cross Section

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325401, Rev. D
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Pendent

A-76 Extended Coverage Light Hazard Pendent Sprinkler - GL8159

Extended Coverage Light Hazard Model GL8159 Pendent

Description and Operation

The Globe Model GL8159 Extended Coverage Pendent Sprinkler for Light Hazard occupancies is a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various light hazard area coverages and should be installed in accordance with NFPA 13. This sprinkler series is available in four temperature ratings and several finishes to meet many varying design requirements.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.


Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (74°C)
    200°F (93°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin based solution, 5mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 3" (7.6 cm) Factory Bronze
1Satin Chrome
Bright Chrome
White Polyester2
Black Polyester2
1Lead Coated
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as UL listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
cULus
Pendent GL8159 8.1
*1/2 Orifice listed for all hazards

U.L. Listing Design - Use Requirements For Light Hazards

StyleTEMPArea of
Coverage
MIN. PRESSURE
P.S.I.
Flow in
G.P.M.
Standard Pendent
Recessed Pendent
135°F / 57°C
155°F / 68°C
175°F / 79°C
200°F / 93°C
16' x 16' 10.3 26
18' x 18' 16.6 33
20' x 20' 24.4 40
Note: Due to the high spray pattern created by the spinkler, there must be a minmum spacing of 8'-0" between sprinklers to eliminate the risk of cold soldering.

Cross Sections

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 312366
  • Quantity - Recessed Wrenches - P/N 325401, Rev. D
  • Quantity - Protective Caps - P/N 327109-CAP
    (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Intermediate In-Rack Storage Sprinklers

A-75 Intermediate Level Sprinkler

GL Series Intermediate Level Upright/Pendent

Description and Operation

The Globe GL Series Intermediate Level Sprinklers are primarily designed for use in rack storage sprinkler systems, where their thermosensitive elements must be shielded from the water spray of higher elevation sprinklers which could operate earlier during a fire. The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element.

The Globe Intermediate Level Sprinklers are available in either upright or pendent styles, with 1/2" or 17/32" orifices, in several temperature ratings and with various finishes to meet customer requirements. Each unit is factory fitted with a water shield having a 3 25/32" diameter. Either style may be provided with sprinkler head guards for use where mechanical injury might be expected.

The heart of Globe’s GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C),
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin based solution, 5mm size
  • Shield - brass or steel - 3 25/32" diameter

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes1
5.6 (80 metric) 1/2" NPT 2 1/4"
(5.7 cm)
Factory Bronze
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm)
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • 1Finishes available on request.

Approvals

StyleSin
Model
K
Factor
135°
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
cULusFMNYC - DOB
MEA 101-92-E
Upright
GL5663 5.6
GL8163 7.8* -
GL8166 8.1
Pendent GL5672 5.6
GL8172 7.8*
GL8158 8.1
*17/32" X 1/2" NPT.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » High Pressure Sprinklers

A-73 High Pressure Model GL5657 Adjustable Concealed Pendent

High Pressure Model GL Series Adjustable Concealed Pendent

Description and Operation

The Globe High Pressure Model GL Series Concealed Pendent Sprinkler offers the ultimate in low profile, aesthetically pleasing appearance. It is available with 1/2" of adjustment, and may be used in areas where flowing and static pressure do not exceed 300 psi. Globe's Concealed Sprinkler utilizes its frangible glass ampule type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens discharging water onto the floor in its required and approved distribution pattern.

 

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate;
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate;
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate;
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate;
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate.
  • Water Working Pressure Rating - 300 psi (21 Bars).
  • Factory tested hydrostatically to 850 psi (59 Bars).
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C).
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size.
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

Classification Available Sprinkler Temperatures Bulb Color N.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread Size Length Finishes1
5.6 (80 metric) 1/2" NPT 2 1/4"
(5.7 cm)
Bright Chrome
White Painted
Bright Brass
Other Painted Finishes
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order. Painted plates other than white required customer to finish paint.

Approvals

Style Sin
Model
K
Factor
135°F (57°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
135°F (57°C)
175°F (79°C)
with plate
155°F (68°C)
200°F (93°C)
with plate
155°F (68°C)
cULus
Concealed
Pendent
GL5657 5.6*
*1/2 Orifice listed for all hazards

Cross Sections

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 325391
  • Quantity - Protective Caps - P/N 327119

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » High Pressure Sprinklers

A-72 High Pressure Concealed Pendent Sprinkler - GL5655

High Pressure Model GL5655 Concealed Pendent

Description and Operation

The Globe High Pressure Model GL5655 Concealed Pendent Sprinkler offers the ultimate in low profile, aesthetically pleasing appearance. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate color finished to match the specifier's exact requirements. The Model GL5655 Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling, and may be used in areas where flowing and static pressure do not exceed 300 psi. Globe's Concealed Sprinkler utilizes its frangible glass ampule type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens discharging water onto the floor in its required and approved distribution pattern.

A special spring is attached to the pendent sprinkler deflector that serves to provide a constant tension against the ceiling plate. This feature virtually ensures freedom from environmental vibration problems.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 300 psi (21 Bars)
  • Factory tested hydrostatically to 850 psi (59 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes1
5.6 (80 metric) 1/2" NPT 2 1/4"
(5.7 cm)
Bright Chrome
White Painted
Bright Brass
Other Painted Finishes
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order. Painted plates other than white required customer to finish paint.

Approvals

StyleSin
Model
K
Factor
135°F (57°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
135°F (57°C)
175°F (79°C)
with plate
155°F (68°C)
200°F (93°C)
with plate
155°F (68°C)
cULus
Concealed
Pendent
GL5655 5.6*
*1/2 Orifice listed for all hazards

Cross Sections

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 325391

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent

A-71 Adjustable Concealed (Dome) Pendent Sprinkler

GL Series Adjustable Concealed Pendent

Description and Operation

The Globe GL Series Adjustable Concealed Pendent Sprinkler offers the ultimate in low profile, aesthetically pleasing appearance. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate color finished to match the specifier's exact requirements. The Sprinkler is available with 1/2" of adjustment and a deeper profile cover plate assembly. The GL Series Adjustable Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Adjustable Concealed Sprinkler utilizes its frangible glass ampule type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens discharging water onto the floor in its required and approved distribution pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin based solution, 5mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
2.8 (39 metric) 1/2" NPT 2 1/2"
(6.4 cm)
Bright Chrome
White Painted
Bright Brass1
Satin Chrome1
Other Painted Finishes1
4.2 (59 metric) 1/2" NPT
5.6 (80 metric) 1/2" NPT
8.1 (116 metric) 3/4" NPT
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order. Painted plates other than white required customer to finish paint.

Approvals

StyleSin
Model
K
Factor
135°F (57°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
155°F (68°C)
175°F (79°C)
with plate
155°F (68°C)
200°F (93°C)
with plate
155°F (68°C)
cULus
Concealed
Pendent
GL2856 2.8
GL4256 4.2
GL5656 5.6:*
GL8173 8.1*

:*Listed For All Hazards

Cross Sections

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 325391
  • Quantity - Protective Caps - P/N 327119

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent

A-70 Concealed Pendent Sprinkler

GL Series Concealed Pendent

Description and Operation

The Globe GL Series Concealed Pendent Sprinkler offers the ultimate in low profile, aesthetically pleasing appearance. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate color finished to match the specifier's exact requirements. The Sprinkler is available with 1/8" adjustment and a low profile cover plate assembly. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its frangible glass ampule type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens discharging water onto the floor in its required and approved distribution pattern.

A special spring is attached to the pendent sprinkler deflector that serves to provide a constant tension against the ceiling plate. This feature virtually ensures freedom from environmental vibration problems.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
2.8 (39 metric) 1/2" NPT 2 1/2"
(6.4 cm)
Bright Chrome
White Painted
Bright Brass1
Satin Chrome1
Other Painted Finishes1
4.2 (59 metric) 1/2" NPT
5.6 (80 metric) 1/2" NPT
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order. Painted plates other than white required customer to finish paint.

Approvals

StyleSin
Model
K
Factor
135°F (57°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
155°F (68°C)
175°F (79°C)
with plate
155°F (68°C)
200°F (93°C)
with plate
155°F (68°C)
cULusFMLPCCENYC - DOB
MEA 101-92-E
Concealed
Pendent
GL2854 2.8
GL4254 4.2
GL5654 5.6

Cross Sections

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Protective Caps - P/N 327119

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » "The Inch" - One Inch Adjustable Pendent

A-69 "The Inch" One Inch Adjustable Concealed Pendent - GL5653

"The Inch" Model GL5653 One Inch Adjustable Concealed Pendent

Description and Operation

Sprinklers

The Globe GL5653 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2¾" diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 5mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate.

The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off" designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling.

Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 5mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire.

Technical Data

  • Temperature Ratings - 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating
    is -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 5mm size
  • Drop Pin - stainless steel
  • Cover Plate - brass
  • Upper Escutcheon Assembly - plated steel
Note:Globe's wrench P/N 332765 must be used to install the sprinkler.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K'
Factor
Thread SizeLengthFinishes
5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) Bright Chrome
White Painted
Bright Brass1
Satin Chrome
Other Painted Finishes1
Note:
  • Metric conversions are approximate.
  • 1 Finishes available on special order.

Approvals

StyleSin
Model
K Factor135°F (57°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
135°F (57°C)
155°F (68°C)
with plate
155°F (68°C)
175°F (79°C)
with plate
155°F (68°C)
200°F (93°C)
with plate
155°F (68°C)
cULusFM

NYC-DOS
MEA101-92-E

Adjustable
Concealed
Pendent
GL5653
5.6

Cross Sections

Click image above for a detailed view of this product.

Optional Cover
Plate Sizes
WHITE 135°F
PART #
WHITE 155°F
PART #
CHROME 135°F
PART #
CHROME 155°F
PART #
2 3/4" 332726 332731 332724 332729
3 5/16" 332706 332711 332704 332709

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Adjustable Concealed Wrenches - P/N 332765

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » High Pressure Sprinklers

A-68 High Pressure Recessed Sprinkler

High Pressure Model GL Series Recessed Pendent

Description and Operation

Sprinklers

The Globe High Pressure Model GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it offers greatly increased safety to life and the ability to be used in areas where flowing and static pressure do not exceed 300 psi. This sprinkler series is available in various orifices, temperature ratings and finishes to meet varying design requirements.

The heart of Globe’s Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C),
    200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 300 psi (21 Bars)
  • Factory tested hydrostatically to 850 psi (59 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Orifice SizeNominal 'K'
Factor
Thread SizeLengthFinishes
1/2" (15 mm) 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
Bright Chrome
White Polyester1
Black Polyester1
Lead Coated2
17/32" (20 mm) 7.8 (111 metric) 1/2" NPT *2 1/4" (5.7 cm)
17/32" (20 mm) 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • *Excluding pintle.
  • 1Available as U.L. and C-U.L. listed corrosion resistant when specified on order.
  • 2 Finishes available on special order.

Approvals

StyleSin
Model
Orifice
Size
135° F
57° C
155° F
68° C
175° F
79° C
200° F
93° C
286°F
141°C
†cULus
Pendent
Recessed
GL5652 5.6
GL8152 7.8*
GL8157 8.1
Note:
  • † 1/2" Orifice and 17/32" orifice listed for all hazards.
  • *17/32" X 1/2" NPT.

Cross Sections

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325391, Rev. F (1/2"); P/N 325401, Rev. D (L.O.)
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Standard Response - Standard Spray Sprinkler

A-67 Recessed Pendent & Horizontal Sidewall Sprinkler

GL Series Recessed Pendent Recessed Horizontal Sidewall

Description and Operation

Sprinklers

The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified. This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements.

The heart of Globe’s GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

The sprinkler and escutcheon are not factory assembled. Assembly is done in the field.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C),
    200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Nominal 'K' FactorThread SizeLength1Finishes
2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
Satin Chrome2
Bright Chrome
White Polyester3
Black Polyester3
Lead Coated2
4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm)
5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm)
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm)
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • 1 Horizontal Sidewall is 2 9/16".
  • 2 Finishes available on special order.
  • 3 Available as cULus listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
135° F
57° C
155° F
68° C
175° F
79° C
200° F
93° C
**286°F
141° C
†cULusFMLPCCENYC - DOB
MEA
101-92-E
Pendent
Recessed
GL2851 2.8
GL4251 4.2
GL5651 5.6
GL8151* 7.8*
GL8156 8.1 $
§
Horizontal
Sidewall
Recessed
GL2870 2.8
GL4270 4.2
GL5670 5.6
GL8171 8.1
Note:
  • § Horizontal sidwall cULus listed for deflector 4" to 12" below the ceiling.
  • † 5.6K Orifice, 7.8K Orifice and 8.1K Orifice listed for all hazards.
  • *7.8" X 1/2" NPT
  • ** 286°F cULus listed only.
    $ Brass finish only

Cross Section

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Recessed Wrenches - P/N 325391, Rev. F (1/2"); P/N 325401, Rev. D (L.O.)
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » High Pressure Sprinklers

A-66 High Pressure Model GL Series Upright / Pendent Sprinkler

High Pressure Automatic Sprinklers Model GL Series Upright / Pendent

Description and Operation

Sprinklers

The Globe Model GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified, and has been evaluated for use where static or flowing pressures are 300 psi or below. This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

The sprinkler and escutcheon are not factory assembled. Assembly is done in the field.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C), 200°F (93°C),
    286°F (141°C), 360°F (182°C)
  • Water Working Pressure Rating - 300 psi (21 Bars)
  • Factory tested hydrostatically to 850 psi (59 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Orifice SizeNominal 'K' FactorThread SizeLengthFinishes
1/2" (15 mm) 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
17/32" (20 mm) 7.8 (111 metric) 1/2" NPT *2 1/4" (5.7 cm)
17/32" (20 mm) 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • *Excluding Pintle
  • 1 Finishes available on special order.
  • 2 Available as U.L. and C-U.L. listed corrosion resistant- when specified on order.

Approvals

StyleSin
Model
K
Factor
135° F
57° C
155° F
68° C
175° F
79° C
200° F
93° C
286°F
141° C
cULus
Upright GL5662 5.6
GL8162 7.8*
GL8165 8.1
Pendent GL5652 5.6
GL8152 7.8*
GL8157 8.1
Note:
  • *17/32" X 1/2" NPT

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Standard Response - Standard Spray Sprinkler

A-65 Standard Sprinkler (Upright, Pendent, Sidewall, and Conventional)

GL Series Upright • Pendent Vertical Sidewall Horizontal Sidewall Conventional (Old Style)

Description and Operation

Sprinklers

The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified. This sprinkler series is available in various styles, orifices, temperature ratings and finishes to meet varying design requirements.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

The sprinkler and escutcheon are not factory assembled. Assembly is done in the field.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C), 200°F (93°C) ,
    286°F (141°C), 360°F (182°C)
  • 500°F (260°C) Available Upon Request Without Approvals
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with glycerin solution, 5mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C
Extra High 360°F 182°C Mauve 300°F 149°C

Specifications

Nominal 'K' FactorThread SizeLength1Finishes
2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
Satin Chrome2
Bright Chrome4
White Polyester4
Black Polyester4
Wax Coated3,4
Lead Coated2,4
Wax over Lead3,4
4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm)
5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm)
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm)
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • 1 Horizontal Sidewall is 2 9/16".
  • 2 Finishes available on special order.
  • 3 Wax Coating UL listed up to 200°F only.
  • 4 cULus listed corrosion resistant- Polyester must be specified on order.

Approvals

StyleSin
Model
Orifice
Size
135°
57°
155°
68°
175°
79°
200°
93
286°
141°
360°
182°
cULusFMLPCCE"NYC
- DOB
MEA
101-92-E
Upright GL2861 2.8
GL4261 4.2
GL5661 5.6
GL8161 7.8* -
GL8164 8.1
Pendent GL2851 2.8
GL4251 4.2
GL5651 5.6
GL8151 7.8*
GL8156 8.1
Vertical
Sidewall †
GL5675 5.6
GL8176 8.1

Horizontal
Sidewall §

GL2870 2.8
GL4270 4.2
GL5670 5.6
GL8171 8.1
Conventional
(Old Style)
GL5668 5.6
GL8169 8.1
Note:
  • § Horizontal sidewall UL listed for deflector 4" to 12"below the ceiling, FM approved 4" to 6".
  • † Vertical sidewall UL listed for light hazard only.
    Pendent vertical sidewall UL listed for 6' min. spacing.
    Upright vertical sidewall UL listed for 9' min. spacing.
  • *1/2" NPT

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Size
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.)

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Sprinkler Vertical Sidewall

A-59 Dry Type Vertical Sidewall Sprinkler

Automatic Sprinklers GL Series Dry Type Vertical Sidewall Upright & Pendent

Description and Operation

Sprinklers

The Globe Quick Response GL Series Dry Type Vertical Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe Quick Response GL Series Dry Type Vertical Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C), 200°F (93°C),
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with alcohol based solution, 3mm
  • Orifice insert - brass
  • 3/4" NPT or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Nominal 'K' FactorThread SizeLength1 Finishes
5.6 (80 metric) 3/4" or 1" NPT Variable
to
48"
Factory Bronze
2Satin Chrome
Bright Chrome
White Polyester3
Black Polyester3
2Lead Coated
8.1 (116 metric) 1" NPT
NOTE:
  • Metric conversions are approximate.
  • 1 cULus listed for up to A 48" "A" dimension.
  • 2 Finishes available on special order.
  • 3 cULus listed corrosion resistant- Polyester must be specified on order.

Approvals

StyleSin
Model
K
Factor
Thread
Size
155° F
68° C
175° F
79° C
200° F
93° C
286°F
141° C
*cULusNYC - DOB
MEA 101-92-E
Vertical
Sidewall
GL5643 5.6 1" NPT
GL5644 5.6 ¾" NPT
GL8143 8.1 1" NPT
NOTE:
  • * ¾" NPT x 5.6K orifice and 1" NPT x 8.1K orifice cULus listed for ordinary hazard.
  • Pendent vertical sidewall cULus listed for 6' min. spacing.
  • Upright vertical sidewall cULus listed for 9' min. spacing.

Cross Section


Installation Data

Globe GL Series Dry Vertical sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the end fitting. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

The GL Series Dry Sprinkler must not be installed in a short radius 90° elbow. When installing in other than an iron tee, the clearances between the end of the sprinkler and fitting should be checked.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • Escutcheons desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used; "B" Dimension - Distance from face of fitting to the top of the deflector.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Upright

A-60 Dry Type Upright Sprinkler

Automatic Sprinklers GL Series Dry Type Upright

Description and Operation

Sprinklers

The Globe Quick Response GL SeriesDry Type Upright Sprinkler is designed for use in special applications such as freezing environments. As an example, they may be efficiently used when connected to a wet type sprinkler system and extended into an unheated attic space.

The Globe Quick Response GL Series Dry Type Upright Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C), 200°F (93°C),
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with alcohol based solution, 3mm
  • Orifice insert - brass
  • 3/4" NPT or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT

cULus Variable
to 48"

FM Variable
to 36"

Factory Bronze
1Satin Chrome
Bright Chrome
White Polyester
Black Polyester
2Lead Coated
8.1 (116 metric) 1" NPT
NOTE:
  • Metric conversions are approximate.
  • cULus listed corrosion resistant- Polyester must be specified on order.
  • 1 Finishes available on special order.
  • 2 Lead coated is UL approved only.

Approvals

StyleSin
Model
K
Factor
Thread Size135° F
57° C
155° F
68° C
175° F
79° C
200° F
93° C
286°F
141° C
*FMcULusNYC - DOB
MEA 101-92-E
Upright GL5639 5.6 1" NPT
GL5640 5.6 3/4" NPT
GL8139 8.1 1" NPT
NOTE:
  • Listed for all Harzards
  • Dry Upright Sprinklers require a minimum operating pressure of 12psi
  • * Dry Upright - FM Approved 155°F, 200°F, and 286°F only.

Cross Section

Click image above for a detailed view of this product.

Important Installation Data

Globe GL Series Dry Upright sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

The GL Series Dry Sprinkler must not be installed in a short radius 90° elbow. When installing in other than an iron tee, the clearances between the end of the sprinkler and fitting should be checked.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • "B" Dimension - Distance from face of fitting to the top of the deflector.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Horizontal Sidewall

A-58 Dry Type Horizontal Sidewall Sprinkler

Automatic Sprinklers GL Series Dry Type Horizontal Sidewall Recessed Horizontal Sidewall

Description and Operation

Sprinklers

The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples.

The Globe Quick Response GL Series Dry Type Horizontal Sidewall Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with alcohol based solution, 3mm
  • Orifice insert - brass
  • 3/4" NPT or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Nominal 'K' FactorThread SizeLength2Finishes
5.6 (80 metric) 3/4" or 1" NPT

cULus
Variable to
48"

FM
Variable to
36"


Factory Bronze
1Satin Chrome
Bright Chrome
White Polyester
Black Polyester
2Lead Coated
8.1 (116 metric) 1" NPT
Note:
  • Metric conversions are approximate.
  • cULus listed corrosion resistant: Polyester must be specified on order.
  • 1 Finishes available on special order.
  • 2Lead Coated is UL approved only.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135° F
57° C
155° F
68° C
175° F
79° C
200° F
93° C
286°F
141° C
*FMcULusNYC - DOB
MEA 101-92-E
Horizontial
Sidewall
GL5641 5.6a 1" NPT
GL5642 5.6a 3/4" NPT  
GL8141 8.1b 1" NPT  
Recessed
Horizontial
Sidewall
GL5641 5.6a 1" NPT
GL5642 5.6a 3/4" NPT  
GL8141 8.1b 1" NPT  
Note:
  • aListed for light hazard only with deflector from 4" - 12" below the ceiling.
  • bListed for light and ordinary hazard with deflector from 4" - 12" below the ceiling.
  • * Recessed Horizontal Sidewall - FM Approved 155°F and 200°F only.
  • * Horizontal Sidewall - FM Approved 155°F, 200°F, and 286°F only.

Cross Sections


Important Installation Data

Globe GL Series Dry Horizontal Sidewall sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • Quantity - Recessed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit
    Recessed)
  • Escutcheons desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Concealed Pendent

A-57 Dry Type Adjustable Concealed (Dome) Pendent Sprinkler

Automatic Sprinklers GL Series Dry Type Adjustable Concealed Pendent

Description and Operation

Sprinklers

The Globe Quick Response GL Series Dry Type Adjustable Concealed Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. It offers the ultimate in low profile, aesthetically pleasing appearance. The sprinkler is available with 1/2" of adjustment and a deeper profile ceiling plate, 3 5/16" in diameter, color finished to match the specifier's exact requirements. The quick response sprinkler offers the additional feature of greatly increased safety to life, with operation approximately six times faster than ordinary sprinklers and should be used advisedly and under the direction of approving authorities having jurisdiction. Globe's Dry Adjustable Concealed Sprinkler utilizes its frangible 3mm glass bulb type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuation assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings
    • 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    • 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    • 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    • 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with alcohol based solution, 3mm
  • Orifice insert - brass
  • 3/4" NPT or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLength2Finishes
5.6 (80 metric) 3/4" or 1" NPT Variable to 48" Bright Chrome
White Painted
1Satin Chrome
1Bright Brass
1Other Painted Finishes
8.1 (116 metric) 1" NPT
NOTE:
  • Metric conversions are approximate.
  • 1Finishes available on special order. Painted plates other than white require customer to furnish paint. Contact Globe for paint specification.
  • 2cULus listed for up to a 48" "A" dimension.

Approvals

StyleSin ModelK FactorThread Size135° F (57° C)
w/plate
135° F (57° C)
155° F (68° C)
w/plate
135° F (68° C)
175° F (79° C)
w/plate
155° F (68° C)
200° F (93° C)
w/plate
155° F (68° C)
*cULus
Concealed
Pendent
GL5649 5.6 1"NPT
GL5622 5.6 3/4 NPT
GL8149 8.1 1" NPT
NOTE:
  • *Listed for ALL hazards

Cross Sections

Click image above for a detailed view of this product.

Important Installation Data

Globe GL Series Dry Concealed sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327119
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Concealed Pendent

A-56 Dry Type Concealed Pendent Sprinkler - GL5637

Automatic Sprinklers GL Series Dry Type Concealed Pendent

Description and Operation

Sprinklers

The Globe Quick Response GL Series Dry Type Concealed Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. It offers the ultimate in low profile, aesthetically pleasing appearance. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate color finished to match the specifier's exact requirements. The Quick Response GL Series Dry Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. The quick response sprinkler offers the additional feature of greatly increased safety to life, with operation approximately six times faster than ordinary sprinklers and should be used advisedly and under the direction of approving authorities having jurisdiction. Globe's Dry Concealed Sprinkler utilizes its frangible 3mm glass bulb type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern.

A special spring is attached to the pendent deflector that serves to provide a constant tension against the ceiling plate. This feature virtually ensures freedom from environmental vibration problems.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings
    • 135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    • 155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    • 155°F (68°C) Sprinkler, 155°F (57°C) Cover Plate
    • 175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    • 200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with alcohol based solution, 3mm
  • Orifice insert - brass
  • 3/4" NPT or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 3/4" or 1" NPT cULus Variable to 48"

FM Variable to 36"
Bright Chrome
White Painted
1Satin Chrome
1Bright Brass
1Other Painted Finishes
8.1 (116 metric) 1" NPT
NOTE:
  • Metric conversions are approximate.
  • 1Finishes available on special order. Painted plates other than white require customer to furnish paint. Contact Globe for paint specification.

Approvals

StyleSin ModelK FactorThread Size

135° F
(57° C)
w/plate
135° F
(57° C)

155° F
(68° C)
w/plate
135° F
(57° C)
155°F
(68°C)
w/plate
155°F
(68°C)
175° F
(79° C)
w/plate
155° F
(68° C)
200° F
(93° C)
w/plate
155° F
(68° C)
*FMcULus

NYC-
DOB
MEA
101-92-E

Con-
cealed
Pen-
dent
GL5637 5.6 1"NPT
GL5638 5.6 3/4 NPT -
GL8137 8.1 1" NPT -
Note:
  • Listed for ALL hazards
  • *Concealed Pendent style - FM Approvals 135° F Cover & 155° F Sprinkler; 155° F Cover & 200° F Sprinkler
  • *FM Approved as Standard Response.

Cross Sections

Click image above for a detailed view of this product.

Important Installation Data

Globe GL Series Dry Concealed sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327119
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Extra Large Orifice

A-50 ELO 231/13 Upright Sprinkler - GL1123

Model GL1123 Pendent Extra Large Orifice Automatic Sprinklers For Use in NFPA 13, 231,231C, 231D & 231F Systems

Description and Operation

Quick Response

The Globe Quick Response Model GL1123 Extra Large Orifice Upright Sprinkler is intended for use in NFPA 13, 231, 231C, 231D and 231F Systems when installed in accordance with the Standard Sprinkler Positioning and area / density flow calculation requirements as specified in each respective standard. This sprinkler is intended for use in wet systems only when used for storage applications. When acceptable to the Authority having Jurisdiction the Model GL1123 Sprinkler may be used as a "special application" sprinkler when installed to protect single, double and multiple-row and portable rack storage of Class I - IV group A and B plastics, cartoned, expanded or unexpanded, as well as exposed unexpanded with a maximum storage height of 20 feet, maximum ceiling height of 25 feet, 36 inch minimum deflector to top of storasystems only.

The Model GL1123 is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various area coverages. This sprinkler series is available in the upright style, and several temperature ratings and finishes to meet varying design requirements.

The heart of Globe's Model GL1123 sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 155°F (68°C)
    175°F (79°C), 200°F (93°C), 286°F (141°C).
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Minimum Operating Pressure - 10 psi (.7 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 155°F 68°C Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K' FactorThread SizeLenthFinishes
11.5 (166 metric) 3/4" NPT 2 7/16 (6.19cm)

Factory Bronze
1 Satin Chrome
Bright Chrome
2 White Polyester
2 Black Polyester
1 Lead Coated

Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as UL listed corrosion resistant - when specified on order.

Approvals

StyleSin
Model
K
Factor
155°F (68°C)
175°F (79°C)
200°F (93°C)286°F (141°C)cULusNYC - DOB
MEA - 101-92-E
Upright GL1123 11.5

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010

Product Related Documents

Download this page as a pdf
Dry Sprinklers » Dry Type Pendent

A-55 Dry Type Pendent Sprinkler

Automatic Sprinklers GL Series Dry Type

Description and Operation

Sprinklers

The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. It can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings - 135°F (57°C),
    155°F (68°C), 175°F (79°C) 200°F (93°C),
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with alcohol based solution, 3mm size
  • Orifice insert -brass
  • 3/4" NPT or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225 °F 107°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 3/4" NPT or 1"NPT

cULus Variable
to 48"

FM Variable to
36"

Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester
Black Polyester
Lead Coated2
8.1 (116 metric) 1"NPT
Note:
  • Metric conversions are approximate.
  • cULus listed corrosion resistant: Polyester must be specified on order.
  • 1Finishes available on special order.
  • 2Lead Coated is UL approved only.

Approvals

StyleSin ModelK FactorThread
Size
135°F
(57°C)
155°F
(68°C)
175°F
(79°C)
200°F
(93°C)
286°F
(141°C)
*FMcULus
NYC-DOB
MEA 101-92-E
Pendent GL5635 5.6 1" NPT
GL5636 5.6 3/4" NPT  
GL8135 8.1 1" NPT  
Recessed
Pendent
GL5635 5.6 1" NPT
GL5636 5.6 3/4" NPT  
GL8135 8.1 1" NPT  
Note:
  • Listed for ALL hazards.
  • *Pendent style - FM Approved 155°F, 200°F, and 286°F
  • *Recessed Pendent style - FM Approved 155°F and 200°F

 

Cross Section


Installation Data

Globe GL Series Dry Pendent sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010
  • Quantity - Recessed Wrenches - P/N 337014
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)
  • Escutcheons desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used.

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Horizontal Sidewall

A-47 Extended Coverage Light Hazard Horizontal Sidewall Concealed Sprinkler

Concealed Extended Coverage Horizontal Sidewall For Light Hazard Occupancies

Description and Operation

Quick Response

The Globe Quick Response GL5613 and GL8113 Extended Coverage Horizontal Sidewall Adjustable Concealed Sprinkler for light hazard occupancies, have the lowest profile available for this type of sprinkler, providing an aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards, and in accordance with NFPA 13. The sprinkler has 1/2” of adjustment for ease of installation. All that is seen on the wall is a 3 1/4” diameter wall plate color finished to match the specifiers exact requirements. In addition to making the sprinkler much less noticeable, the wall plate assembly also provides protection for the sprinkler from flying or hanging objects.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. The 3mm frangible glass ampule provides sprinkler operation approximately six times faster than standard response sprinklers, they can also be installed wherever standard extended coverage horizontal sidewall sprinklers are specified. The wall plate is soldered to the sprinkler’s special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the quick response sprinkler. At the rated temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F

38°C

Intermediate 175°F 79°C Yellow 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeFinishes*
5.6 (80 metric) 1/2" NPT

Bright Chrome
White Painted
*Satin Chrome
*Bright Brass
*Other Painted Surfaces

8.1 (116 metric) 3/4" NPT
Note:
  • Metric conversions are approximate.
  • *Finishes available on special order. For painted plates other than white, contact
  •  Globe for ordering specifications.

Approvals

StyleSin
Model
K
Factor
135°F (57°C)
w/plate
135°F (57°C)
155°F (57°C)
w/plate
135°F (57°C)
175°F (79°C)
w/plate
155°F (68°C)
cULusNYC - DOB
MEA - 101-92-E
Concealed
Sidewall
GL5613 5.6
GL8113 8.1

U.L. Listing Design - Use Requirements For Light Hazards

Model
#
K-
Factor
Temp.Ceiling to Deflector DistanceWidth of CoverageLength of CoverageMin. Pressure
P.S.I.
FLOW IN
G.P.M.
GL5613 5.6 135°F / 57°C
155°F / 68°C
175°F / 79°C
4" TO 6" 16' 16' 26.8 29
16' 18' 26.8 29
16' *20' 32.7 32
6" TO 12" 16' 16' 32.7 32
16' 18' 32.7 32
16' *20' 32.7 32
GL8113 8.1 135°F / 57°C
155°F / 68°C
175°F / 79°C
4" TO 12" 16' 16' 10.3 26
4" TO 6" 16' 18' 12.8 29
6" TO 12" 16' 18' 15.6 32
135°F / 57°C
175°F / 79°C
4" TO 6" 16' *20' 15.6 32
6" TO 12" 16' *20' 20.9 37
NOTE:
  • * 155°F not listed in 16' x 20' room size, use either 135°F or 175°F.
  • 7' minimum spacing for GL5613 and 6' minimum spacing for GL8113.

Cross Section

larger image

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - 5.6K Wrenches - P/N 329678
  • Quantity - 8.1K Wrenches - P/N 329679
  • Quantity - Protective Caps - P/N 327119

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Extra Large Orifice

A-48 ELO 13 Pendent Sprinkler - GL1114

Model GL1114 Pendent Extra Large Orifice Automatic Sprinklers For Use in NFPA 13 Systems

Description and Operation

Quick Response

The Globe Quick Response Model GL1114 Extra Large Orifice Pendent Sprinkler for use in NFPA 13 Systems is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. The main use of this sprinkler is when minimal pressure is available and the use of smaller size orifice sprinklers would require the installation of a pump. This sprinkler series is available in upright and pendent styles, various temperature ratings and several finishes to meet many varying design requirements.

The heart of Globe's Model GL1114 sprinkler proven actuating assembly is a hermetically sealed frangible glass am- pule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

Technical Data

  • Temperature Ratings - 155°F (68°C)
    175°F (79°C), 200°F (93°C), 286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Red 100°F

38°C

Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K' FactorThread SizeLenthFinishes
11.5 (166 metric) 3/4" NPT 2 7/16 (6.19cm)

Factory Bronze
1 Satin Chrome
Bright Chrome
2 White Polyester
2 Black Polyester
1 Lead Coated

NOTE:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2C-U.L. Listed corrosion resistant - polyester must be specified on order.

Approvals

StyleSin
Model
K
Factor
155°F (68°C)
175°F (79°C)
200°F (93°C)286°F (141°C)cULusNYC - DOB
MEA - 101-92-E
Pendent GL1114 11.5

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 333010

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Horizontal Sidewall

A-47a Extended Coverage Light Hazard Horizontal Sidewall Sprinkler - GL8114

Concealed Extended Coverage Horizontal Sidewall For Light Hazard Occupancies Model GL8114

Description and Operation

Quick Response

The Globe Quick Response GL8114 Extended Coverage Horizontal Sidewall Adjustable Concealed Sprinklers for light hazard occupancies have the lowest profile available for this type of sprinkler, providing an aesthetically pleasing design. They can be installed wherever standard extended coverage horizontal sidewall sprinklers are specified when allowed by the applicable standards, and in accordance with NFPA 13. The sprinkler has 1/2” of adjustment for ease of installation. All that is seen on the wall is a 3 1/4” diameter wall plate color finished to match the specifiers exact requirements. In addition to making the sprinkler much less noticeable, the wall plate assembly also provides protection for the sprinkler from flying or hanging objects.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. At the rated temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. The wall plate is soldered to the sprinkler’s special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the quick response sprinkler.

Technical Data

  • Temperature Ratings - 135°F (57°C) Sprinkler,
    135°F (57°C) Cover Plate
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F 57°C Orange 100°F 38°C

Specifications

Nominal 'K' FactorThread SizeFinishes*
8.1 (116 metric) 3/4" NPT Bright Chrome
White Painted
*Satin Chrome
*Bright Brass
*Other Painted Surfaces
Note:
  • Metric conversions are approximate.
  • *Finishes available on special order. For Painted plates other than white, contact
  •  Globe for ordering specifications.

Approvals

StyleSin
Model
K
Factor
135°F (57°C)
w/plate
135°F (57°C)
cULusNYC - DOB
MEA - 101-92-E
Concealed
Sidewall
GL8114 8.1

U.L. Listing Design - Use Requirements For Light Hazards

Model
#
K-FactorTemp.Ceiling to Deflector DistanceWidth of CoverageLength of CoverageMIN. PRESSURE
P.S.I.
FLOW IN
G.P.M.
* GL8114 8.1 135°F / 57°C
4" TO 6" 16' 22' 19.8 36
16' 24' 23.2 39
6" TO 12" 16' 22' 24.4 40
4" TO 12" 18' 20' 19.8 36
18' 22' 24.4 40
NOTE:
  • * 6' Minimum Spacing

Cross Sections

larger image

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - 8.1K Wrenches - P/N 329679
  • Quantity - Protective Caps - P/N 327119

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Horizontal Sidewall

A-46 Extended Coverage Light Hazard Horizontal Sidewall Sprinker - GL8128 & GL8129

Extended Coverage Automatic Sprinklers Model GL8128, GL8129 Horizontal Sidewall

Description and Operation

Quick Response

The Globe Quick Response Models GL8128 and GL8129 Extended Coverage Horizontal Sidewall Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While this Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard extended coverage horizontal sprinklers are specified; but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accordance with NFPA 13.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
  • Water Working Pressure Rating -
    175 psi (1207 kPa)
  • Factory tested hydrostatically to 500 psi (3448 kPa)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 3" (7.6.cm) Factory Bronze
*Satin Chrome
Bright Chrome
+White Polyester
+Black Polyester
*Lead Coated
NOTE:
  • Metric conversions are approximate.
  • *Other finishes available on special order.
  • +Available as cULus listed corrosion resistant when specified on order.

Approvals

StyleSin
Model
K
Factor
135°F
(57°C)
155°F
(68°C)
175°F
(79°C)
200°F
(93°C)
cULusNYC - DOB
MEA 101-92-E
Sidewall GL8128 8.1
GL8129 8.1

U.L. Listing Design - Use Requirements For Light Hazards

Sin Model*
StyleTemp.Ceiling to Deflector
Distance
Width of
Coverage
Length of
Coverage
Min. Pressure
P.S.I.
FLOW IN
G.P.M.
GL8128 Standard
&
Recessed
135°F / 57°C
155°F / 68°C
175°F / 79°C
200°F / 93°C
4" TO 6" 16' 16' 10.3 26
18' 12.8 29
GL8129 Standard
&
Recessed
135°F / 57°C
155°F / 68°C
175°F / 79°C
6" TO 12" 16' 10.3 26
18' 12.8 29
GL8128 Standard
&
Recessed
135°F / 57°C 4" TO 6" 20' 16'.6 33
GL8129 6" TO 12"
GL8128 Standard 175°F / 79°C 4" TO 6"
GL8129 6" TO 12"
GL8128 Standard
&
Recessed
135°F / 57°C 4" TO 6" **22' 20.8 37
GL8129 6" TO 12" **24' 26.8 42

 *Minimum 6' sprinkler spacing

**Listed with recessed cup with 1/2" adjustment

Cross Sections

larger image

Click image above for a detailed view of this product.

 

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 312366
  • Quantity - Recessed Wrenches - P/N 325401, Rev. D
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Horizontal Sidewall

A-44 Extended Coverage Light Hazard Horizontal Sidewall Sprinkler - GL5628

Extended Coverage Automatic Sprinklers Model GL5628 Horizontal Sidewall

Description and Operation

Quick Response

The Globe Quick Response Model GL5628 Extended Coverage Horizontal Sidewall Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While these Quick Response Sprinklers provide an aesthetically pleasing appearance, they can be installed wherever standard extended coverage horizontal sprinklers are specified; but offer the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accordance with NFPA 13.

The heart of Globe's Model GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 1/2" NPT 2 1/2" (7.6 cm) Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
NOTE:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as cULus listed corrosion resistant when specified on order.

Approvals

StyleSin ModelK Factor135°F
(57°C)
155°F
(68°C)
175°F
(79°C)
200°F
(93°C)
cULusNYC-DOB
MEA 101-92-E
Sidewall GL5628 5.6

U.L. Listing Design - Use Requirements For Light Hazards

Model
#
StyleTemp.Ceiling to
Deflector
Distance
Width of
Coverage
Length of
Coverage
Min.
Pressure
P.S.I.
Flow in
G.P.M.
GL5628 Standard &
Recessed
135°F/57°C
155°F/68°C
175°F/79°C
4" TO 12" 16' 16' 21.6 26
16' 18' 26.8 29
18' 18' 32.7 32
Standard &
Recessed
200°F/93°C 4" TO 6" 16' 16' 21.6 26
16' 18' 26.8 29
18' 18' 32.7 32

Cross Section

larger image

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Standard Wrenches - P/N 325390
  • Quantity - Recessed Wrenches - P/N 325391
  • Quantity - Protective Caps - P/N 327109-CAP
    (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Extended Coverage Light Hazard Sprinklers » Extended Coverage Light Hazard Pendent

A-41 Extended Coverage Light Hazard Pendent Sprinkler - GL8109

Extended Coverage Light Hazard Automatic Sprinklers Model GL8109 Pendent

Description and Operation

Quick Response

The Globe Quick Response Model GL8109 Extended Coverage Pendent Sprinkler for Light Hazard occupancies is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While this Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard light hazard extended coverage pendent sprinklers are specified; but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accordance with NFPA 13.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

Technical Data

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 3" (7.6 cm) Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.
  • 2Available as cULus listed corrosion resistant when specified on order.

Approvals

StyleSin ModelK Factor135°F
(57°C)
155°F
(68°C)
175°F
(79°C)
200°F
(93°C)
cULus
Pendent GL8109 8.1

U.L. Listing Design - Use Requirements For Light Hazards Only

Sin ModelStyleTempArea of Coverage
MIN. PRESSURE
P.S.I.
Flow in
G.P.M.
GL8109 Standard
&
Recessed
135°F / 57°C
155°F / 68°C
175°F / 79°C
200°F / 93°C
16' x 16' 10.3 26
18' x 18' 16.6 33
135°F / 57°C 20' x 20' 24.4 40
Note: Due to height spray pattern created by this sprinkler, there must be a minimum spacing of 8'-0" between sprinklers to eliminate the risk of cold soldering.

Cross Section

larger image

Click image above for a detailed view of this product

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 312366
  • Quantity - Recessed Wrenches - P/N 325401, Rev. D
  • Quantity - Protective Caps - P/N 327109-CAP (Friction Fit Recessed)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Intermediate In-Rack Storage Sprinklers

A-39 Intermediate Level Upright & Pendent Sprinkler

Automatic Sprinklers GL Series Intermediate Level Upright • Pendent

Description and Operation

Quick Response

The Globe Quick Response GL Series Intermediate Level Sprinklers are primarily designed for use in rack storage sprinkler systems, where their thermosensitive elements must be shielded from the water spray of higher elevation sprinklers which could operate earlier during a fire. The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. The Quick Response Sprinkler can be installed wherever standard intermediate level sprinklers are specified. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction and in accordance with their listings.

The Globe Intermediate Level Sprinklers are available in either upright or pendent styles, with 1/2" or 17/32" orifices, in various temperature ratings and with various finishes to meet customer requirements. Each unit is factory fitted with a water shield having a 3 25/32" diameter. Either style may be provided with sprinkler head guards for use where mechanical injury might be expected.

The heart of Globe’s GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used.

Technical Data

  • Temperature Ratings
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Shield - brass or steel - 3 25/32" diameter.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes*
5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze
7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm)
8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm)
Note:
  • Metric conversions are approximate.
  • *Other finishes available on request.

Approvals

StyleSin ModelK Factor135°F
(57°C)
155°F
(68°C)
175°F
(79°C)
200°F
(93°C)
286°F
(141°C)
cULusFM
Upright GL5617 5.6
GL8117 7.8*
GL8120 8.1
Pendent GL5612 5.6
GL8112 7.8*
GL8108 8.1
* 17/32" X 1/2" NPT.

 

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L.O.)

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » "The Inch" - One Inch Adjustable Pendent

A-38 “The Inch” One Inch Adjustable Concealed Pendent - GL5606

Quick Response

"The Inch" Automatic Sprinklers Model GL5606, One Inch Adjustable Concealed Pendent

Description and Operation

Quick Response

The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1" of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate or an optional 2¾" diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate.

The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on - screw off" designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling.

Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 155°F (68°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating
    - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Deflector - brass
  • Screw - brass
  • Frame - bronze
  • Bulb seat - brass
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Drop Pin - stainless steel
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel
  • Globe's wrench P/N 332765 must be used to install this sprinkler.

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
5.6 (80 metric) 1/2" NPT 2 1/2" (6.4 cm) Bright Chrome
White Painted1
Satin Chrome1
Other Painted Finishes1
Note:
  • Metric conversions are approximate.
  • 1Finishes available on special order.

Approvals

StyleSin ModelK Factor135°F
(57°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
155°F
(68°C)
175°F
(79°C)
with plate
155°F
(68°C)
200°F
(93°C)
with plate
155°F
(68°C)
cULus*FM

NYC-DOS
MEA101-92-E

Adjustable
Concealed
Pendent
GL5606 5.6
Note:
  • *FM Approved as Standard Response

Cross Section

larger image

Click image above for a detailed view of this product.

Optional Cover Plate SizesWhite 135°F
Part #
White 155°F
Part #
Chrome 135°F
Part #
Chrome 155°F
Part #
2 3/4" 332726 332731 332724 332729
3 5/16" 332706 332711 332704 332709

 

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Adjustable Concealed Wrenches - P/N 332765

Product Related Documents

Download this page as a pdf
Sprinklers » Standard Spray Sprinklers » Concealed Pendent » Extended Coverage Light Hazard Sprinklers

A-37 Extended Coverage Light Hazard Concealed (Dome) Pendent Sprinkler - GL8104

Automatic Sprinklers Model GL8104 Concealed Pendent

Description and Operation

Quick Response

The Globe Quick Response Model GL8104 Extended Coverage Concealed Pendent Sprinkler is a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards, and in accordance with NFPA 13. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. All that is seen at the ceiling is a 3 9/32" diameter ceiling plate color finished to match the specifier's exact requirements. The Model GL8104 Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The ceiling plate is soldered to the sprinkler's special upper support assembly in three places. Upon the application of sufficient heat, the plate falls to the floor exposing the quick response pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens discharging water onto the floor in its required and approved distribution pattern.

A special spring is attached to the pendent sprinkler deflector that serves to provide a constant tension against the ceiling plate. This feature virtually ensures freedom from environmental vibration problems.

Technical Data

  • Temperature Ratings -
    135°F (57°C) Sprinkler, 135°F (57°C) Cover Plate
    155°F (68°C) Sprinkler, 135°F (57°C) Cover Plate
    175°F (79°C) Sprinkler, 155°F (68°C) Cover Plate
    200°F (93°C) Sprinkler, 155°F (68°C) Cover Plate
  • Water Working Pressure Rating -
    175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - copper
  • Spring - nickel alloy
  • Seal - teflon
  • Bulb - glass with alcohol based solution, 3mm size
  • Cover Plate - brass
  • Upper Escutcheon Assembly - steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum
Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C

Specifications

Nominal 'K' FactorThread SizeLengthFinishes
8.1 (116 metric) 3/4" NPT 2 1/2" (6.4 cm) Bright Chrome
White Painted
*Satin Chrome
*Bright Brass
*Other Painted Finishes
Note:
  • Metric conversions are approximate.
  • *Finishes available on special order.  For painted plates other than white, contact Globe
  •  for ordering specifications.

Approvals

StyleSin ModelK Factor135°F
(57°C)
with plate
135°F
(57°C)
155°F
(68°C)
with plate
135°F
(57°C)
175°F
(79°C)
with plate
155°F
(68°C)
200°F
(93°C)
with plate
155°F
(68°C)
cULusNYC - DOB
MEA 101-92-E
Concealed
Pendent
GL8104 8.1

U.L. Listing Design - Use Requirements For Light Hazards

StyleSin ModelTemprRoom SizeMIN.
PRESSURE
P.S.I.
FLOW
G.P.M.
Concealed
Pendent
GL8104 135°F / 57°C
155°F / 68°C
175°F / 79°C
200°F / 93°C
16' x 16' 10.3 26
18' x 18' 15.6 32
135°F / 57°C 20' x 20' 24.4 40

Minimum 8' Sprinkler Spacing

Cross Section

larger image

Click image above for a detailed view of this product.

Ordering Information

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Thread Sizes
  • Temperature
  • Finishes desired
  • Quantity - Concealed Wrenches - P/N 325401
  • Quantity - Protective Caps - P/N 327119

Product Related Documents

Related Products

  • No related products found

Globe Product Warranty

Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment.

For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).

Bulletin: GL4906   Last Revised: September 2011   Revision: 1

Bulletin: CLEAN ROOM   Last Revised: May 2009  

Bulletin: EQ ESCUTCHEON   Last Revised: May 2009  

Bulletin: EQ ESCUTCHEON   Last Revised: May 2009  

Bulletin: GL5679-EQ   Last Revised: August 2010   Revision: 1

Bulletin: GL8159-EQ   Last Revised: May 2009  

Bulletin: GL5635-EQ   Last Revised: July 2010   Revision: 1

Bulletin: GL8109-EQ   Last Revised: May 2009  

Bulletin: GL5651-EQ   Last Revised: April 2009  

Bulletin: BULLETIN GL2801-EQ   Last Revised: April 2009  

Bulletin: BULLETIN GL 3010   Last Revised: September 2011   Revision: 1

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR    Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: GL4202   Last Revised: December 2009  

Bulletin: GL4252   Last Revised: December 2009   Revision: 1

Last Revised: July 2009  

Bulletin: GL5653-EQ   Last Revised: April 2010   Revision: 1

Bulletin: GL5653/5606   Last Revised: May 2009   Revision: 7

Bulletin: GL5606-EQ   Last Revised: April 2009   Revision: 2

Bulletin: BULLETIN ONE INCH ADJ CONC   Last Revised: March 2008   Revision: 3

Bulletin: 3   Last Revised: March 2008   Revision: BULLETIN MILL CAUTION

Bulletin: 10   Last Revised: July 2010   Revision: BULLETIN DRY CAUTION

Bulletin: 4   Last Revised: March 2008   Revision: BULLETIN CAUTION

Bulletin: STDR   Last Revised: June 2002   Revision: 2

Bulletin: SPRCAB   Last Revised: August 2002   Revision: 2

Bulletin: GL5610   Last Revised: September 2011   Revision: 1

Bulletin: SPRWR   Last Revised: July 2009   Revision: 3

Bulletin: ESCUTCH   Last Revised: October 2007   Revision: 2

Bulletin: A05-176-06   Last Revised: July 1999   Revision: 491

Bulletin: A05-972-02   Last Revised: November 1999   Revision: 578

Bulletin: A05-177-05   Last Revised: November 1999   Revision: 566

Last Revised: March 2002  

Last Revised: March 2009  

Last Revised: March 2009  

Last Revised: March 2002  

Bulletin: A05-180-06   Last Revised: June 2000   Revision: 45

Bulletin: TESTDRAIN   Last Revised: December 2009   Revision: 1

Bulletin: BUTTERFLY   Last Revised: February 2010   Revision: 4

Bulletin: BUTTERFLY   Last Revised: February 2010   Revision: 4

Bulletin: BUTTERFLY   Last Revised: February 2010   Revision: 4

Bulletin: BUTTERFLY   Last Revised: February 2010   Revision: 4

Bulletin: RCV   Last Revised: January 2010   Revision: 3

Bulletin: JFN   Last Revised: February 2008   Revision: 4

Bulletin: WS   Last Revised: June 2002   Revision: 3

Bulletin: H2,3 REV #1   Last Revised: July 2010  

Bulletin: H1 REV #1   Last Revised: July 2010  

Bulletin: AAFD   Last Revised: June 2002   Revision: 3

Bulletin: DPV-D   Last Revised: February 2007   Revision: 3

Bulletin: DPV-F-3   Last Revised: June 2002   Revision: 5

Bulletin: RET.CHM.   Last Revised: June 2002   Revision: 2

Bulletin: BULLETIN ACV-8H   Last Revised: May 2003   Revision: 2

Bulletin: ACV   Last Revised: August 2010   Revision: 7

Bulletin: WM   Last Revised: August 2002  

Bulletin: ESCUTCH   Last Revised: October 2007   Revision: 2

Bulletin: ASB-ESCTL   Last Revised: August 2002   Revision: 2

Bulletin: ASB-HG   Last Revised: May 2006  

Bulletin: ASB-HGWS   Last Revised: May 2006  

Bulletin: GL5687   Last Revised: August 2010   Revision: 9

Bulletin: GL5683   Last Revised: April 2007   Revision: 8

Bulletin: GL5685   Last Revised: August 2010   Revision: 14

Bulletin: GL5677   Last Revised: August 2010   Revision: 9

Bulletin: GL5681   Last Revised: August 2010   Revision: 12

Bulletin: GL5679   Last Revised: August 2010   Revision: 11

Bulletin: GL1167   Last Revised: August 2002   Revision: 1

Bulletin: GL1160   Last Revised: March 2003   Revision: 2

Bulletin: GL8128-STD   Last Revised: October 2003   Revision: 5

Bulletin: GL8159   Last Revised: October 2003   Revision: 3

Bulletin: GL5653   Last Revised: January 2004   Revision: 3

Bulletin: GL300PSIAC   Last Revised: April 2004   Revision: 2

Bulletin: GL5655   Last Revised: October 2003   Revision: 2

Bulletin: GL2856   Last Revised: October 2003   Revision: 3

Bulletin: GL2854   Last Revised: December 2006   Revision: 7

Bulletin: GL5653   Last Revised: July 2009   Revision: 6

Bulletin: GL300PSIR   Last Revised: September 2004   Revision: 2

Bulletin: GL5651   Last Revised: April 2009   Revision: 8

Bulletin: GL300PSI   Last Revised: September 2004   Revision: 1

Bulletin: GL5661   Last Revised: December 2006   Revision: 3

Bulletin: GL5643   Last Revised: August 2010   Revision: 8

Bulletin: GL5639   Last Revised: August 2010   Revision: 9

Bulletin: GL5641   Last Revised: July 2010   Revision: 14

Bulletin: GL5649   Last Revised: July 2010   Revision: 10

Bulletin: GL5637   Last Revised: July 2010   Revision: 13

Bulletin: GL1123   Last Revised: October 2002   Revision: 3

Bulletin: GL5635   Last Revised: July 2010   Revision: 13

Bulletin: GL5613   Last Revised: February 2005   Revision: 7

Bulletin: GL1114   Last Revised: August 2002   Revision: 2

Bulletin: GL8114   Last Revised: February 2005   Revision: 1

Bulletin: GL8128   Last Revised: October 2003   Revision: 5

Bulletin: GL5628   Last Revised: July 2009   Revision: 5

Bulletin: GL8109   Last Revised: July 2005   Revision: 5

Bulletin: GL5603   Last Revised: June 2003   Revision: 3

Bulletin: GL5606   Last Revised: July 2009   Revision: 5

Bulletin: GL8104   Last Revised: July 2005   Revision: 6

site by visual chutzpah