Dry Sprinklers » Dry Type Sprinkler Vertical Sidewall

A-94 Dry Type Vertical Sidewall Sprinkler

GL Series Dry Type Vertical Sidewall Upright & Pendent

White Dry Adjustable Concealed Pendent

The Globe GL Series Dry Type Vertical Sidewall Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples.

The Globe GL Series Dry Type Vertical Sidewall Sprinkler utilizes a frangible glass ampule sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern.

The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern.

  • Temperature Ratings -
    135°F (57°C)
    155°F (68°C)
    175°F (79°C)
    200°F (93°C)
    286°F (141°C)
  • Water Working Pressure Rating - 175 psi (12 Bars)
  • Factory tested hydrostatically to 500 psi (34 Bars)
  • Maximum low temperature glass bulb rating is
    -67°F (-55°C)
  • Frame - bronze
  • Deflector - brass
  • Screw - brass
  • Bulb seat - brass
  • Spring - teflon coated nickel alloy
  • Retainer - brass
  • Pin - stainless steel
  • Torsion spring - stainless steel
  • Bulb - glass with glycerin solution, 5mm size
  • Orifice insert - brass
  • 3/4" or 1" NPT
  • Outer tube - galvanized steel pipe
  • Inner tube - stainless steel

Sprinkler Temperature Rating/Classification and Color Coding

ClassificationAvailable Sprinkler TemperaturesBulb ColorN.F.P.A. Maximum Ceiling Temperature
Ordinary 135°F/155°F 57°C/68°C Orange/Red 100°F 38°C
Intermediate 175°F/200°F 79°C/93°C Yellow/Green 150°F 66°C
High 286°F 141°C Blue 225°F 107°C

Specifications

Nominal 'K'
Factor
Thread SizeLength*Finishes
5.6 (80 metric) 3/4" or 1" NPT Variable
to 48"
Factory Bronze
Satin Chrome1
Bright Chrome
White Polyester2
Black Polyester2
Lead Coated1
Wax Coated1
Wax Over Lead1
8.1 (116 metric) 1" NPT
Note:
  • Metric conversions are approximate.
  • *cULus listed for up to a 48" "A" dimension.
  • 1Finishes available on special order
  • Wax coating cULus listed up to 200°F.
  • 2C-U.L. listed corrosion resistant - polyester must be specified on order.

Approvals

StyleSin
Model
K
Factor
Thread
Size
135°F
57°C
155°F
68°C
175°F
79°C
200°F
93°C
286°F
141°C
*cULusNYC - DOB
MEA 101-92-E
Vertical
Sidewall
GL5687 5.6 1" NPT
GL5688 5.6 3/4" NPT
GL8187 8.1 1" NPT
Note:
  • *3/4" NPT x 5.6K orifice and 1" NPT x 8.1K orifice listed for ordinary hazard.
  • Pendent vertical sidewall cULus listed for 6' min. spacing.
  • Upright vertical sidewall cULus listed for 9' min. spacing.


Globe GL Series Dry Vertical sprinklers should be installed in accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler head wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit.

The GL Series Dry Sprinkler must not be installed in a short radius 90° elbow. When installing in other than an iron tee, the clearances between the end of the sprinkler and fitting should be checked.

When installed in a wet system extending into a freezing area, see chart on Dry Caution Sheet for minimum exposed barrel length to prevent ice plugs.  Please refer to our Dry Caution Sheet for further important installation data.

 

 

When ordering please specify the following.

  • Quantity
  • Model Number
  • Style
  • Orifice
  • Temperature
  • Finishes desired
  • "A" Dimension - Distance from face of fitting to the finished ceiling line regardless of escutcheon used;
    "B" Dimension - Distance from face of fitting to the top of the deflector.

Product Related Documents

Related Products

Globe Product Warranty

Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment.

For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).

Bulletin: GL5687   Last Revised: August 2010   Revision: 9